2. Setup
VNA-300M-PCI
13
Setting the Board ID
If you install two or more boards on one personal computer, assign a different ID value to each of the
boards to distinguish them.
The board IDs can be set from 0 - Fh to identify up to sixteen boards.
If only one board is used, the original factory setting (Board ID = 0) should be used.
Setting Procedure
To set the board ID, use the rotary switch on the board. Turn the SW1 knob to set the board ID as
shown below.
BOARD ID
01
2
3
4
5
67
9A
B
C
D
EF
8
SW1
Factory setting :
(Board ID = 0)
Figure 2.2. Board ID Settings (SW1)
Mode switch (SW2)
Select loader mode or normal mode.
ON
OFF
1 2
Figure 2.3. Mode switch
Table 2.1. Mode switch
DIP switch
Details
1 (Reserved)
2 (MODE)
OFF
OFF
Use this setting during normal operation.
OFF
ON
The product will start in loader mode. Use this mode when
performing maintenance such as when the firmware no longer starts
normally.