CHAPTER 6 - RAID Controller
48
SPI-8450-LLVA
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No RAID Mode Total Drv Capacity(MB) Status
Array 1 Mirror 2 16126 Critical
Array 2 —— —— —— ——
Array 3 —— —— —— ——
Array 4 —— —— —— ——
[ Keys Available ]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
9.
Highlight the array whose Status is Critical.
10.
Press [Enter]. The following screen will then appear.
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No
RAID Mode Total Drv
Status
Array 2
Mirror
2
Critical
Stripe Block: Not Available
[ Select Drive for Rebuild ]
Channel:ID Drive Model
Capacity (MB)
1 : Slave
QUANTUMCR8.4A
8063
[ Keys Available ]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
11.
Under [Select Drive for Rebuild], highlight the replacement drive.
12.
Press [Enter] and confirm that the data will be copied on to the selected drive. All data on
the replacement drive will be written over with mirrored information from the array drive.
A progress bar will appear as below.
Please Wait While Duplicating The Image
10% Complete
13.
Once the rebuild process is complete, the user will be asked to reboot the system.
Summary of Contents for SPI-8450-LLVA
Page 7: ...Table of Contents vi SPI 8450 LLVA...
Page 37: ...CHAPTER 3 Jumper setting 30 SPI 8450 LLVA...
Page 43: ...CHAPTER 5 BIOS SETUP 36 SPI 8450 LLVA...
Page 79: ...CHAPTER 6 RAID Controller 72 SPI 8450 LLVA...
Page 97: ...CHAPTER 8 BIOS Setup 90 SPI 8450 LLVA 8 6 Integrated Peripherals...