2. Setup
SMC-4DL-PCI, SMC-8DL-PCI
19
Step 5 Checking Operations with the Diagnosis
Program
Use the diagnosis program to check that the board and driver software work normally, thereby you can
confirm that they have been set up correctly.
What is the Diagnosis Program?
The diagnosis program diagnoses the states of the board and driver software.
For Quick Check, the program checks the board resources for validity. The resources include the I/O
addresses, interrupt level (IRQ), board ID, and sync signal.
For Detail Check, the program checks the connections of the motor control board, driver unit, and limit
sensor for validity. The program inputs/outputs signals in interactive mode to check for validity. Check
items are Limit Signals Input, Control Signals Input/Output and Pulse Signals Output.
Check method
Perform the input/output test and check the execution environment with the driver unit connected.
The dedicated screw terminal CCB-SMC2 will come in handy when you check the board.
The board should be checked with the factory defaults.
For direct connection to the board, see Chapter 3 “External Connection”.
Connection diagram
The following connection diagrams show connections using the dedicated screw terminal CCB-SMC2.
<Pulse output>
CCW
CCB-SMC2
Driver Unit
CW+
CW-
CCW-
CW+
CW-
CCW+
CCW-
CCW+
CW
Figure 2.5. Connection diagram < 1 / 2 >