6. Software RAID setup
EPC-2020 Series User’s manual
87
RAID setup when replacing the HDD
The EPC-2010 series is installed with a RAID-1 Array created. However, if a HDD is replaced, you must
reconfigure the mirroring RAID drive in the Array.
Set up the RAID in accordance with the following procedure.
CAUTION
RAIDs in the EPC-2010 series are not hot-swappable. Always turn off the power before replacing a
HDD.
1. Replace the HDD and boot the PC.
Intel(R) Rapid Storage Technology - Option ROM - 10.5.0.864
Copyright(C) 2003-11 Intel Corporation. All Right Reserved.
RAID Volumes:
ID Name Level Strip Size Status Bootable
0 Volume0 RAID1(Mirror) N/A **GB Degraded Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
* *********** ************* ***GB Non-RAID Disk
* *********** ************* ***GB Non-RAID Disk
Press <CTRL-I> to enter Configuration Utility..
2. Press the <Ctrl> and <I> keys in the above screen to start the RAID utility. When the RAID utility
launches, the following screen will appear with the replaced HDD indicated.
“Degraded” volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
* ***** ********** ********** ***GB
[ DEGRADED VOLUME DETECTED ]
[
↑↓
]-Previous/Next [ENTER]-SelectDisk [ESC]-Exit