4. Functions
AI-1604CI2-PCI
47
Channel conversion order
Normally, when converting more than one channel during one sampling session, the channels are
converted starting from channel 0, as shown below.
The channel conversion order for this product is fixed. It does not require any software setting.
Range
“Range” means the range of voltages at which analog input can be performed.
The input range can be selected by setting the upper and lower input signals.
AI-1604CI2-PCI
: The range is specified by setting both the jumpers and software.
Please refer to the “Chapter2 Setup - Setting the Hardware - Setting the Analog Input”.
Memory
Device’s or driver’s input data storage memory is used to enable advanced analog input processing at
high speed. For the memory, the FIFO or ring format can be selected by means of software.
AI-1604CI2-PCI
: The product uses the memory for storing converted data on the driver.
- FIFO
format
In the FIFO (First In First Out) format, input data items are read from memory in the same order in
which they were written to the memory. Input data items are fed out of the memory sequentially,
where the oldest one is always read from the memory. The status monitor and application
notification functions are provided, which check and report the state in which the memory has
stored a fixed amount of data or in which the memory has become full.
The FIFO memory is used to obtain all input data from analog input in a short or infinite period of
time.
Summary of Contents for AI-1604CI2-PCI
Page 1: ...PC HELPER Isolated Analog Input Board for PCI AI 1604CI2 PCI User s Guide CONTEC CO LTD...
Page 7: ...vi AI 1604CI2 PCI...
Page 15: ...1 Before Using the Product 8 AI 1604CI2 PCI...
Page 41: ...2 Setup 34 AI 1604CI2 PCI...
Page 65: ...4 Functions 58 AI 1604CI2 PCI...
Page 78: ...5 About Software AI 1604CI2 PCI 71 Analog output Digital input and output...