2. Setup
18
ADI12-16(PCI)
Setting the Analog Input
The analog input is set by specifying the input mode and input range.
For the input mode setting function, see Chapter 4 “Functions”.
Setting the Input Mode
The input mode is the method of connecting analog input signals. The single-ended and differential
input modes are available.
Use JP11 to JP13 to set the desired input mode.
Figure 2.4. Setting the Input Mode
Do not set the jumpers to any strapping pattern other than those specified above. Doing so can
result in a fault in the board.
Single-ended input
Differential input
JP13
1 2 3
JP11
1 2 3
JP12
1 2 3
JP20
1 2 3
JP13
1 2 3
JP11
1 2 3
JP12
1 2 3
JP20
1 2 3
CAUTION