25
Electrical connection
:
Risk of electric shock!
Components inside the appliance may have sharp edges.
These may damage the connecting cable. Do not kink or pinch
the connecting cable during installation.
The required connection data can be found on the rating plate
inside the appliance; to do this, remove the metal mesh grease
filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference suppression
regulations.
:
Risk of electric shock!
It must always be possible to disconnect the appliance from the
electricity supply. The appliance must only be connected to a
protective contact socket which has been correctly installed. If
the plug is no longer accessible following installation of the
appliance, or a fixed connection is required, an all-pole isolating
switch must be present on the installation side with a contact
gap of at least 3 mm. The fixed connection must only be
installed by an electrician.
Preparing the units
■
The fitted unit must be level and have sufficient load-bearing
capacity.
■
The max. weight of the extractor hood is 18 kg.
Appliance dimensions and safety clearances
■
Observe the appliance's dimensions.
■
Comply with the safety clearances.
If the installation instructions for the gas cooking appliances
specify a different distance, the largest distance must always be
provided for.
The fitted unit must be heat-resistant up to 90 °C. The fitted unit
must still be sturdy after the cut-outs have been made.
To install an upper cabinet, this extractor hood must be
provided with the following dimensions:
1.
Make the cut-out for the exhaust air pipe. To do this, make an
opening in the ceiling or back wall of the fitted unit with an
additional recess for the power cord.
2.
If the cabinet base is present, remove this. Mark the securing
points on the inside of the cabinet and pre-cut the holes
using a piercer. Use the enclosed template to mark the
securing points.
¨
3.
Screw in the four enclosed screws for the angle bracket up to
5 mm.
©
Width
600 mm
Depth
Min. 320 mm
Height
Min. 390 mm
PP
PP