22. Power adapter for fixed installation (cont’d) 

23. Open Window Detection 

locking screws 

USB power ports 

temperature sensor 

wall fixing 

wall fixing 

The CRX2 is guaranteed for one year against faulty material or workmanship. This applies only if the appliance has been used for 
purposes in accordance with the instructions provided and has not been misused, neglected, damaged, modified or repaired 
by any person not authorised by us. This guarantee is offered to you as an extra benefit and does not affect your legal rights. 
 
Reasonable care has been taken to ensure that this guide is accurate at the time of printing. In the interest of progress, the 
Company reserve the right to vary specifications from time to time without notice. 

 

Should you need any advice on the use of you new Consort product please contact our Helpline: 
 

Consort Equipment Products Limited 

Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT 

Tel:  01646 692172   |   Fax: 01646 695195 

Email: [email protected]        Web: www.consortepl.com 

Operation hours:  Mon to Thu 8.30am to 4.30pm  |   Fri 8.30am to 3.30pm 

BS EN ISO 9001 Registered Company No FM12671 

 

Customer Helpline 

24. Setup menu 

1. 

Touch and hold      and      icons together for 10 
seconds. 

2. 

The CRX2 will enter the setup menu. 

3. 

Use      and      to change a value. 

4. 

Use      to scroll between the settings. 

 

01 – temperature calibration 
The temperature reading has been factory calibrated but if 
for any reason it needs adjusting (better accuracy required, 
to suit different position in the room etc.), the reading can be 
recalibrated in 0.5 degrees steps. 

Please note that if the unit is powered by the power adapter, the 
temperature reading REQUIRES recalibration. Lower the value by 1.5 
degrees.
 

 

02 – change between degrees Celsius or Fahrenheit 

 

03 – set minimum temperature 
        (- - - = heating OFF, 4deg = frost protection) 

 

04 – set maximum temperature 

 

05 - information about the software version 

06 - 0 or 1 manual mode enable / disable 

07 - open window detection  0 = off,  1 = on 

08 - 600 - open window detection time 600 seconds 

09 - 2 - temperature drop of 2°C in the detection time 

10 - 30 - closed window detection time of 30 seconds 

11 -  2 - temperature rise of 2°C in the detection time

 

Ensuring you don’t waste energy on heating the outside 
world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically  
detect a temperature rise,  and switch itself back on. 
Once enabled in the setup menu, the open window  
detection is fully automatic and does not require any 
human intervention to be activated.   

 

 Setting-up Open Window Detection 
The system has been factory set to default time and  
temperature values. If necessary, all values can be  
adjusted. When the heating is on, open window  
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2

°

C in less than 

10 minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2

°

C in less 

than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 