Intended use

1. 

The fl oor light is intended for illumination of courtyards and garden paths in unshielded exterior areas.

Unauthorised conversion and/or modifi cation of the device are inadmissible because of safety and approval 
reasons (CE). Any usage other than described above is not permitted and can damage the product and lead to 
associated risks such as short-circuit, fi re, electric shock, etc. Please read the operating instructions thoroughly 
and keep them for further reference.

Content of delivery 

2. 

Floor light

• 

Illuminant GX53, 9 W

• 

Hexagonal wrench

• 

Suction cup

• 

Operating instructions

• 

Safety instructions

3. 

We do not assume liability for resulting damages to property or personal injury if the 
product has been abused in any way or damaged by improper use or failure to observe 
these operating instructions. The warranty/ guarantee will then expire!
The icon with exclamation mark indicates important information in the operating 
instructions. Carefully read the whole operating instructions before operating the device, 
otherwise there is risk of danger.

Personal safety

Keep the fl oor light out of the reach of children! There is a risk of a fatal electric shock.

• 

To avoid eye injuries, do not look at the light source or point the light at persons or animals.

• 

Do not carelessly leave the packaging material lying around since this may become a dangerous toy for 

• 

children.

Product safety

The device must not be exposed to extreme temperatures, strong vibrations or heavy mechanical stress.

• 

The fl oor light is only to be operated with a supply voltage of 220 - 240 V~ / 50 Hz. Never try to operate the 

• 

wall-mounted exterior lamp with a different voltage, this will destroy it.
Do not use the fl oor light in rooms or under adverse ambient conditions where combustible gases, vapours 

• 

or dust are or may be present!
The fl oor light is protected according to IP67.

• 

The fi rst number „6“ indicates complete protection against contact with parts under tension or inner 

 -

moving parts and protection against penetration by dust.
The second number „7“ indicates that water can not penetrate in damaging quantities, when the 

 -

equipment is submerged under defi ned circumstances.

If you have reason to assume that safe operation is no longer possible, disconnect the device immediately 

• 

and secure it against inadvertent operation. It can be assumed that safe operation is no longer possible if:

the device shows visible signs of damage

 -

the device no longer operates

 -

the device was stored under unfavourable conditions for a long period of time or

 -

the device was exposed to extraordinary stress caused by transport.

 -

The stainless steel lid must not come into contact with salt water.

• 

Miscellaneous

In commercial institutions, the accident prevention regulations of the employer’s liability insurance 

• 

association for electrical systems and operating facilities are to be observed.
Servicing, adjustment or repair works must only be carried out by a specialist/ specialist workshop.

• 

If any questions arise that are not answered in this operating instruction, contact our Technical Advisory 

• 

Service or other experts.

Mounting preparations

4. 

The  fl oor light may only be installed by a qualifi ed technician who is familiar with the 
relevant regulations (e.g. VDE, German electrical wiring regulations)!
Improper work carried out on the mains voltage endangers not only your life but also the 
life of others!
If you do not have the expertise required for the installation, do not install it yourself but 
ask a qualifi ed technician.

Please note:

The fl oor light is intended for fl oor mounting, e.g. in garden paths.

• 

The fl oor light can be mounted and operated in unshielded outdoor areas due to the design and the IP67 

• 

protection class. Do not operate the fl oor light in or under water.
The fl oor light must be secured on the subdistribution board provided by user by a 10/16A fuse. An earth 

• 

leakage circuit breaker must be installed before this, (FI protective switch). 
The fl oor light must be disconnected from the power supply during installation. It is not suffi cient to just turn 

• 

off the light switch!
Turn the power off and remove the electric circuit fuse or switch off the circuit breaker. Assure it against an 
unauthorised re-start, e.g. with a danger sign.
Check that the mains connection is free of current e.g. with an appropriate tester.

• 

Mounting

5. 

Pay attention to the information in chapter „Mounting preparations“!

Screw off the three Allen head screws from the stainless steel cover.

1. 

Remove the stainless steel cover as well as the glass cover.

2. 

Loosen the recessed fl oor light’s three screws using a Phillips screwdriver.

3. 

Remove the recessed fl oor light from the mounting sleeve.

4. 

Choose the appropriate mounting position for the mounting sleeve. Pay attention to the right orientation of 

5. 

the mounting sleeve when you want to align the Allen screw of the stainless steel cover e.g. with the edge 
of a building.
Check the correct height of the stainless steel cover of the fl oor light before fi xing it and insert the mounting 

6. 

sleeve proportionally deep.

When installed professionally (e.g. with concrete-casting), the recessed fl oor light can be loaded 
with a weight of up to 1000 kg. However, scratches will increasingly occur on glass and stainless 
steel cover!

Lay the mains lead (Ø 10 - 14 mm) through the mounting sleeve from the bottom side.

7. 

Make sure that the mains lead is not damaged by the mounting sleeve’s sharp edges! 
Pass the mains lead underground at an ample depth. Use a suitable protective conduit 
for the cable.
Pass all cables in a way they cannot be damaged e.g. while gardening (digging a 
fl owerbed).

Loosen one of the two nuts on the recessed fl oor light’s underside and guide the feeder into the inside of 

8. 

the recessed fl oor light.
Connect the feeder to the terminal strip (brown cable = L , blue cable = N).

9. 

In case of doubt, contact a qualifi ed technician and do not carry out the connection and 
mounting yourself. Make sure the cable is not stripped too long; this could also cause 
short-circuit or suchlike.

Place the illuminant into the applicable light fi tting and screw the illuminant in, in clockwise direction, until 

10. 

it engages.

You might want to use the suction cup for this. Press the suction cup carefully to the edge of the 
illuminant (not its centre) and screw the illuminant in by turning the suction cup. Do not exert too 
much pressure onto the refl ector pane, since it can easily break.

Insert the recessed fl oor light into the mounting sleeve and screw the light in tightly using the three 

11. 

previously loosened screws.
Insert the glass cover.

12. 

Finally, fasten the stainless steel cover using the three Allen head screws.

13. 

Switch on the mains voltage again and make sure that the ground light fi xture is functioning.

14. 

If the bulb in the fl oor light does not light up, switch off the mains voltage immediately 
(take out fuse or switch off circuit breaker).
Subsequently check the connection of the wall-mounted exterior lamp or the light bulb.
In case of doubt contact a professional (e.g. an electrician).

Replacing the illuminant

6. 

First switch off the mains voltage (take out fuse or switch off circuit breaker).

1. 

Screw off the three Allen head screws from the stainless steel cover.

2. 

Remove the stainless steel cover as well as the glass cover.

3. 

If applicable, let the defective illuminant cool down (risk of burns) and remove the illuminant by screwing it 

4. 

off in counterclockwise direction.
Place a suitable illuminant (GX53 socket, max. 11 W) into the applicable light fi tting and screw the illuminant 

5. 

in, in clockwise direction, until it engages.

You might want to use the suction cup for this. Press the suction cup carefully to the edge of the 
illuminant (not its centre) and screw the illuminant in by turning the suction cup. Do not exert too 
much pressure onto the refl ector pane, since it can easily break.

Insert the glass cover.

6. 

Finally, fasten the stainless steel cover using the three Allen head screws.

7. 

Switch on the mains voltage again and make sure that the ground light fi xture is functioning.

8. 

If you use a light bulb with a higher capacity there is a risk of overheating and fi re 
hazard!

Care and maintenance

7. 

The fl oor light is maintenance-free except for an occasional exchange of the light bulb. Therefore never 

• 

disassemble it (except to mount it or to exchange the light bulb as described in this manual).
Switch off the fl oor light resp. disconnect it from the mains voltage before cleaning.

• 

The outside of the fl oor light should only be wiped off with a clean, soft, dry cloth. For stronger contamination, 

• 

use a cloth which is slightly moistened with lukewarm water.
Do not use aggressive cleaning agents or chemical solutions which could damage the housing (discolouring) 

• 

or impair operation.

Disposal

8. 

In order to preserve, protect and improve the quality of environment, protect human health and 
utilise natural resources prudently and rationally, the user should return unserviceable product to 
relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and not as 
municipal waste.

Technical data

9. 

Operating voltage:

220 - 240 V/AC, 50/60 Hz

Base:

GX53, max. 11 W

Protection class:

IP67

Max. load:

1000 kg

Installation diameter:

130 mm

Installation depth:

130 mm

Dimensions (Ø x H):

140 x 131 mm

Weight:

800 g

These operating instructions are a publication by Conrad Electronic SE, Klaus-

Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation 

reserved. Reproduction by any method, e.g. photocopy, microfi lming, or the capture 

in electronic data processing systems require the prior written approval by the 

editor. Reprinting, also in part, is prohibited. These operating instructions represent 

the technical status at the time of printing. Changes in technology and equipment 

reserved.

© 2009 by Conrad Electronic SE.

*02_11/09_01-SB

Summary of Contents for GX53

Page 1: ... der Einbauhülse wenn Sie die Innensechskantschrauben des Edelstahldeckels z B an einer Gebäudekante ausrichten wollen Kontrollieren Sie bei einem Festeinbau vorher die richtige Höhenlage des Edelstahldeckels der 6 Bodeneinbauleuchte und setzen Sie die Einbauhülse entsprechend tief ein Bei fachgerechter Montage der Einbauhülse z B Einbetonieren kann die Bodeneinbauleuchte mit einem Gewicht von bis...

Page 2: ...eve when you want to align the Allen screw of the stainless steel cover e g with the edge of a building Check the correct height of the stainless steel cover of the floor light before fixing it and insert the mounting 6 sleeve proportionally deep When installed professionally e g with concrete casting the recessed floor light can be loaded with a weight of up to 1000 kg However scratches will incr...

Page 3: ... a position correcte de la gaine si vous 5 désirez aligner les vis à six pans creux du couvercle en acier inoxydable sur le bord d un bâtiment p ex Avant de procéder à un montage fixe vérifiez la hauteur du couvercle en acier inoxydable du luminaire et 6 placez la gaine à une profondeur correspondante En cas de montage approprié du dispositif de mise en place par ex par bétonnage le luminaire de s...

Page 4: ...or de inbouwhuls Let op de juiste plaatsing van de inbouwhuls 5 wanneer u de zeskante inbusschroeven van het roestvrij stalen deksel bv aan de hoek van een gebouw wilt uitrichten Controleer bij een vaste inbouw vooraf of de hoogte van het roestvrij stalen deksel van de 6 bodeminbouwverlichting juist is en plaats de inbouwhuls dienovereenkomstig diep Bij deskundige montage van de inbouwhuls bv in b...

Reviews: