a) Setting the decalcification time (‘
CALC
CALC
CALC
CALC
CALC
’)
The valve is completely opened and closed once a week. This prevents deposits from blocking
the valve. You can use the special ‘
CALC
CALC
CALC
CALC
CALC
’ function to change the time at which the
decalcification cycle is carried out.
• Press the ‘
PROG
’ button until ‘
Sond
Sond
Sond
Sond
Sond
’ is displayed. Then release the ‘
PROG
’ button.
• Use the scroller to select the special ‘
CALC
CALC
CALC
CALC
CALC
’ function.
• Confirm this by pressing the ‘
PROG’
button.
0
6
12
18
24
MO DI
MI
DO FR SA SO
Figure 29
• Use the scroller to select the day of the week (arrow up symbol ‘
a
’ beneath the respective
day of the week).
• Confirm the day of the week you have selected by pressing the ‘
PROG
’ button. The time at
which the decalcification cycle will be carried out now appears in the first line of the LCD.
0
6
12
18
24
MO DI
MI
DO FR SA SO
Figure 30
• Use the scroller to change the time.
• Confirm the decalcification time that you have set by pressing the ‘
PROG
’ button. The
heating control now returns to the normal operating mode.