Frost Protection

•  The heat wave heater is equipped with a frost protection guard.
•  Connect the power plug to an outlet. Turn the thermostat dial (7) to position   . As soon as the room 

temperature sinks below approx. +5 °C, the heat wave heater turns on automatically.

Tip and Overheating Protection

Tip Protection

The unit is equipped with a tip protection, which automatically shuts off the heating function, if the unit has 

tipped over. As soon as the unit stands upright again, the heating function is reactivated. Secure the unit to 

prevent accidental tipping.

Overheating Protection

The heat wave heater is equipped with an automatic shut-off. Should the protective screen (9) be obstructed, 

for instance, or if the temperature e130 °C, the automatic shut-off is activated. To start the heat 

wave heater again, proceed as follows:
1.  Turn the 0 1 2 switch (2) to position 0, and turn the thermostat dial (7) counterclockwise to position   (Off).
2.  Pull the power plug out of the outlet and allow the heat wave heater to cool to room temperature.
3.  Important! Find out why the heat wave heater shut off automatically. If the cause remains unknown, 

contact a qualified technician.

4.  Once you have remedied the cause for the automatic shut-off, you can use the heat wave heater again.

Maintenance and cleaning

Never use aggressive cleansers or chemical solvents. They might damage the housing and 

impair the functioning of the unit. 
Do not press too hard on the surfaces, as this may lead to scratches or dents.

•  Except for an occasional cleaning, the unit is maintenance free.
•  Turn the unit off before cleaning, and pull the plug from the socket. Allow the unit to cool off sufficiently.
•  Use a dry, soft and clean cloth to clean the unit.
•  Remove dust from the protective screen (9) using a long bristled, soft and clean brush, or a hoover

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.

You thus fulfil the legal requirements and make your contribution to protecting the environment.

Technical data

Operating voltage ..........................230 V/AC, 50 Hz
Protection class .............................IP24
Power consumption .......................max. 1000 W (BN 671575)

.......................................................

max. 1500 W (BN 671577)

Power level switch I .......................650 W (BN 671575)

.......................................................

900 W (BN 671577)

Power level switch I + II .................1000 W (BN 671575)

.......................................................

1500 W (BN 671577)

Suitable for rooms up to ................15 m

(BN 671575)

.......................................................

20 m

(BN 671577)

Cord length ....................................175 cm
Dimensions (W x H x D)............. ...approx. 570 x 420 x 80 mm (BN 671575)

.......................................................

approx. 775 x 420 x 80 mm (BN 671577)

Weight ...........................................4.4 kg (BN 671575)

.......................................................

5.4 kg (BN 671577)

Assembly

a) Install track roller mounts

If the product is used as a floor mounted device, it must be operated with the track roller mounts 

and track rollers (10). Use the handle (1), to carry and move the unit. Attention! Do not move 

the unit while hot.

1.  Install both track roller mounts with rollers (10) at the underside of the heat wave heater. Please refer 

to fig.1.

2.  The unit is completely assembled and ready to the use.

Fig. 1

1

2

Fig. 2

b) Wall Installation

If the track roller mounts (10) have already been installed on the heater, unlock the track roller 

mount block and remove the roller mount. Please refer to fig.2.

1.  Secure the wall mount to the wall with the screws and wall plugs provided.

Install the heat wave heater at least 0.6 m above the floor. Make sure to leave at least 1 m of 

unobstructed space in front of the unit.

2.  Turn both locks of the wall mount to the open position (vertically). Fasten the heat wave heater to the 

wall mount

3.  Lock the heat wave heater to keep it from falling off. To do this, use a screwdriver to turn the left lock 90° 

counterclockwise and the right lock clockwise. Please refer to fig.3.

Fig. 3

Operation

When using the unit for the first time, heated parts of the housing might emit a temporary 

nuisance odour. Should this happen, air the room where the unit is set up.
Place the unit on a sufficiently large, stable, heat resistant and level surface. Make sure the 

product cannot roll away by itself (not in case of wall installation).

1.  Make sure the 0 1 2 switch (2) is in position “0”.
2.  Turn the thermostat dial (7) to position   .
3.  Connect the power plug to a suitable outlet.
4.  Turn the unit on by pressing the 0 1 2 switch (2). The operating light (6) comes on. The following power 

settings are available:

 - Position “1”  

Heating function with max. 650 W (BN 671575), max. 900 W (BN 671577)

 - Position “2” 

Heating function with max. 1000 W (BN 671575), max. 1500 W (BN 671577)

5.  Turn the thermostat dial (7) all the way clockwise. The indicator light (4, 5) lights up as soon as the 

heating function is activated. In position “2”, both indicator lights come on simultaneously. The heat wave 

heater begins to heat up.

6.  As soon as the desired room temperature is reached, turn the thermostat dial (7) slowly counterclockwise 

to the desired position. Desired position means a temperature setting that is comfortable for you. Find 

the position by trying.

7.  As  soon  as  the  selected  temperature  is  reached,  the  thermostat  temporarily  shuts  off  the  heating 

function. In this case, the indicator light (4, 5) goes off, and the operating light (6) lights up. Once the 

temperature has gone down approxi3 °C, the heat function is reactivated.

8.  Move the 0 1 2 switch (2) to “0” to turn off the unit.
9.  Disconnect the plug from the outlet when the unit is not in use.

Summary of Contents for 67 15 75

Page 1: ...regler 8 Netzkabel mit Netzstecker 9 Schutzgitter 10 Laufrollenhalter mit Laufrollen Wärmewelle 1000 W 1500 W Version 08 13 Best Nr 67 15 75 67 15 77 Bestimmungsgemäße Verwendung Das Produkt dient zur Aufheizung von Innenräumen mittels Wärmewellen Technologie Das Produkt verfügt über zwei Heizstufen Thermostat und Frostschutzwächter Bei Überhitzung oder im Falle eines Umkippens schaltet sich das P...

Page 2: ...wünschte Position Mit gewünschter Position wird hier eine Temperaturstufe bezeichnet die für Sie angenehm ist Finden Sie die Position durch Ausprobieren 7 Sobald die eingestellte Temperatur erreicht ist schaltet der Thermostat die Heizfunktion vorübergehend aus In diesem Fall erlischt die Kontrollleuchte 4 5 und der Betriebsindikator 6 leuchtet auf Sobald die Temperatur um ungefähr 3 C abfällt wir...

Page 3: ...s plug from the mains socket if you do not use the device for an extended period of time Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety Make sure that the mains cable is not squeezed bent damaged by sharp edges or put under mechanical stress Avoid excessive thermal stress on the mains cable from extreme heat or cold Do not modify the mains cable Otherwise th...

Page 4: ...900 W BN 671577 Power level switch I II 1000 W BN 671575 1500 W BN 671577 Suitable for rooms up to 15 m2 BN 671575 20 m2 BN 671577 Cord length 175 cm Dimensions W x H x D approx 570 x 420 x 80 mm BN 671575 approx 775 x 420 x 80 mm BN 671577 Weight 4 4 kg BN 671575 5 4 kg BN 671577 Assembly a Install track roller mounts If the product is used as a floor mounted device it must be operated with the t...

Page 5: ...teur de la prise de courant Pour des raisons de sécurité débranchez la fiche de secteur de la prise de courant par temps d orage Veillez à ce que le câble d alimentation ne soit pas écrasé plié endommagé par des arêtes vives ou ne soit exposé à d autres contraintes mécaniques Évitez les sollicitations thermiques excessives du cordon d alimentation liées à une chaleur ou à un refroidissement extrêm...

Page 6: ...s de maximum 15 m2 BN 671575 20 m2 BN 671577 Longueur du câble 175 cm Dimensions L x H x P env 570 x 420 x 80 mm BN 671575 env 775 x 420 x 80 mm BN 671577 Poids 4 4 kg BN 671575 5 4 kg BN 671577 Montage a Fixer le support de roulettes Lorsque l appareil est utilisé sur pied il doit fonctionner uniquement avec les supports de roulettes et les roulettes 10 Grâce à la poignée 1 vous pouvez transporte...

Page 7: ...e daarvoor bestemde greepvlakken Neem de netstekker uit de contactdoos als u deze langere tijd niet gebruikt Neem bij onweer de netstekker altijd uit de contactdoos Zorg dat het netsnoer niet wordt afgekneld geknikt door scherpe randen wordt beschadigd of op andere wijze mechanisch wordt belast Vermijd overmatige thermische belasting van het netsnoer door te grote hitte of koude Verander het netsn...

Page 8: ...I 1000 W BN 671575 1500 W BN 671577 Geschikt voor ruimtes tot 15 m2 BN 671575 20 m2 BN 671577 Kabellänge 175 cm Afmetingen B x H x D ca 570 x 420 x 80 mm BN 671575 ca 775 x 420 x 80 mm BN 671577 Gewicht 4 4 kg BN 671575 5 4 kg BN 671577 Montage a Rolhouders bevestigen Wanneer het product wordt gebruikt als een zelfstandige eenheid kan het alleen met de rolhouder en rollers 10 worden verplaatst Met...

Reviews: