5.  Preparations for Installation

The product may only be installed and mounted by a qualified technician 

(e.g. electrician), who is familiar with the relevant regulations (e.g. VDE, 

German electrical wiring regulations)!
Improper work, carried out on the mains voltage, endangers not only your 

own life but also the life of others! If you do not have the expertise required 

for the installation, do not install it yourself but ask a qualified technician.

Observe the safety instructions!

•  Only install the LED floodlight on a stable surface.

•  The LED floodlight must be protected on the sub-distribution board by a 10/16 A fuse. An 

earth leakage circuit breaker must be installed before this (FI protective switch).

•  The LED floodlight must be disconnected from the power supply during installation. It is 

not sufficient to just turn off at the light switch! Turn the power off and ensure that all the 

poles are not carrying a current by removing the electric circuit‘s fuse, or switching off at 

the circuit breaker. Secure it against unauthorised reconnection, e.g., with a danger sign. 

In addition, switch off the associated ground fault circuit interrupter.

• 

Check that the mains connection is current free with a suitable tester.

Only use a cable for the mains connection, which is suitable for being 

permanently laid outdoors.

6.  Installation

Note the information in the “Preparations for Installation” chapter, and the 

installation illustrations in these operating instructions.

1. 

Fasten the mounting bracket for the LED floodlight using at least two screws at a 

suitable location on the wall. Depending on the installation location, suitable screws 

and, if necessary, screw anchors are to be used. 

 

The ideal installation height is between 2.5 and 3 m, depending where it is installed, 

and the ambient conditions (position of the area to be lit).

When drilling mounting holes or screwing down, ensure that no existing electrical 

cable, gas or water pipes are damaged!

2. 

Remove  the  cover  of  the  installation  box  on  the  back  of  the  LED  floodlight,  by 

unscrewing all four fixing screws from the cover. (see Ill. 1).

3.  Loosen the cap nut for the cable gland. (see Ill. 2).

4.  Remove the handle of the strain relief by unscrewing the two screws (see Ill. 2).

5.  Remove the insulation on the mains cable to the required length. The earth conductor 

should be slightly longer than conductor (L) and conductor (N) (see Ill. 3).

6.  Insert the power cable through the cable gland.

7. 

Connect the power cable with the terminal strip in the LED floodlight (see Ill. 4):

 

-

brown wire = L

 

-

blue wire = N

 

-

Green-yellow wire = PE / protective earth conductor / earthing symbol

The protective earth conductor must be connected!

If  the  LED  floodlight  is  replacing  an  existing  light  and  no  protective  earth 

conductor is available, the LED floodlight must not be installed. First, draw a 

new mains cable.

Where the protective earth is not connected, a fault with the mains voltage might 

result in the metal housing of the LED floodlight becoming live. There is a risk of 

a life-threatening electric shock!

Make sure only the minimum required length of the cable is stripped; otherwise 

it could cause a short-circuit.

Also check the other screw connections on the terminal strip (for the connection 

cables to the light electronics) and tighten them if necessary.

8.  Fasten the mains cable to the strain relief. Attach the handle of the strain relief 

previously removed and screw it firmly in place (see Ill. 4).

9.  Screw the cable gland‘s cap nut tight so the rubber seal inside the cable gland is 

sealed (see Ill. 4).

10. 

Attach the cover previously removed and screw it firmly in place with four screws (see Ill. 5).

11. 

Adjust the LED floodlight angle so that it illuminates the desired area. For this, loosen 

both screws on the sides of the bracket, set the angle and tighten the screws again.

12.  Switch on the mains voltage again and make sure that the lamp is working.

If the LEDs in the LED floodlight do not light up, switch off the power immediately 

and please have the connection of the lamps checked by a technician (e.g. 

electrician)!

7.  Maintenance and Care

•  The LED floodlight is maintenance-free, this is why you should never open or dismantle 

it (apart from the connection / installation described in this operating manual).

• 

You should occasionally clean dust and dirt off the glass plate on the lamp to ensure 

proper functioning.

•  Switch off the LED floodlight or disconnect it from the mains voltage before cleaning. Let 

it cool down sufficiently.

•  The exterior of the LED floodlight should only be wiped with a clean, soft, dry cloth. 

Where it becomes very dirty, use a cloth which is slightly moistened with lukewarm water.

• 

Do not use aggressive cleaning agents or chemical solutions that could damage the 

housing (discolouring) or impair operation.

• 

Do not press too hard on the housing or the glass plate, as scratches might appear.

Never spray water e.g. with a garden hose or a high-pressure cleaner, at the 

LED floodlight!

8.  Disposal

Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product according to 

the relevant statutory regulations.

9.  Technical Data

Operating voltage:

110 – 240 V/AC, 50/60 Hz

Power consumption:

max. 3.8 W

Protection class:

I

Protection type:

IP65

Installation location:

Interior/exterior

Light source:

60 LEDs with 0.06 W each, not exchangeable

Colour temperature:

6,000 – 7,000 K 

Luminous flux:

210 lm

Beam angle:

60°

Ambient temperature:

-10 to +50 °C

Dimensions (W x H x D): 102 x 135 x 55 mm

Weight:

approx. 306 g

Summary of Contents for 57 74 62

Page 1: ...arf nur durch eine Fachwerkstatt durchgef hrt werden In gewerblichen Einrichtungen sind die Unfallverh tungsvorschriften des Verbandes der gewerblichen Berufsgenossenschaften f r elektrische Anlagen u...

Page 2: ...D Flutlichtstrahler siehe Abb 4 Braunes Kabel L Blaues Kabel N Gr n gelbes Kabel PE Schutzleiter Erdungssymbol Der Schutzleiter muss angeschlossen werden Wenn der LED Flutlichtstrahler als Ersatz f r...

Page 3: ...ngerous plaything for children Any maintenance or repair work may only be performed by an authorised repair shop In commercial institutions the accident prevention regulations of the employer s liabil...

Page 4: ...Insert the power cable through the cable gland 7 Connect the power cable with the terminal strip in the LED floodlight see Ill 4 brown wire L blue wire N Green yellow wire PE protective earth conducto...

Page 5: ...mat riel d emballage Cela pourrait constituer un jouet dangereux pour les enfants La maintenance ou les r parations ne doivent tre effectu es que par un atelier sp cialis Dans les installations indus...

Page 6: ...Voir fig 4 conducteur marron L conducteur bleu N conducteur vert jaune PE conducteur de protection symbole de mise la terre Raccordez imp rativement le conducteur de protection Si le projecteur LED r...

Page 7: ...het verpakkingsmateriaal niet rondslingeren dit kan voor kinderen gevaarlijk speelgoed zijn Laat het product uitsluitend door een vakman of gespecialiseerde werkplaats onderhouden of repareren Bij in...

Page 8: ...het netsnoer door de kabeldoorvoering 7 Sluit nu het netsnoer aan op de klemmenstrook in de LED schijnwerper zie afb 4 bruine kabel L blauwe kabel N groen gele kabel PE aardingskabel aardingssymbool...

Reviews: