Malfunction

Possible cause

The mains power supply 

Is the green power indicator (2) of the mains

does not work

power supply lit?
Check the mains voltage (you may also want to
check the mains fuse in the device or the line cir-
cuit breaker).

Connected consumers 

Correct voltage set?

do not work

Correct polarity?
Overload of the mains power supply (display 7)?
Check the technical data of the consumers.

The output voltage of 

The mains power supply has been switched to 

13.8 V cannot be changed

the fixed voltage mode.
Change the position of the fixed voltage switch
underneath the device.

Periodically check the technical safety of the device, e.g. check for damage to the
housing etc.

Any other repair work must always be carried out by qualified

experts familiar with the hazards involved and with the relevant
regulations. Unauthorized modifications and repairs of or inside
the device lead to expiry of the warranty.

21

• Do not leave mains power supplies and the connected consumers in operation

unattended.

• Exclusively use fuses of the type and rated current specified. It is absolutely imper-

missible to use repaired fuses.

• Avoid the use of uninsulated metallic cables.

• It is impermissible to connect multiple switched-mode mains power supply units in

series or in parallel.

• Power supply units are not designed for application to human beings or animals.

• If you have reasons to assume that safe operation is no longer possible, immedia-

tely take the device out of operation and secure it against inadvertent operation.
Reasons to assume that safe operation is no longer possible include:
- there is visible evidence that the device has been damaged
- the device does not work any longer
- the device has been stored for long periods of time under unfavourable conditions

or

- it was subject to considerable stress during transport.

• You should also heed the additional safety instructions in each chapter of these

operating instructions as well as in the operating instructions of the connected
devices.

Functional Description

The SPS 1525 PFC and SPS 1540 PFC mains power supply units use switching net-
work technology with the advantages of weight and size reductions. Switched-mode
mains power supply units use chopped mains voltages and return a broad spectrum
of harmonic waves to the mains line, which may cause interference in other devices.
To suppress these harmonic waves, a PFC (Power Factor Correction) has been inte-
grated in the two device models.

The dc output is dc-isolated and features a fuse disconnector to the mains voltage. 

The output voltage can be adjusted by means of the adjustment control (6) from 3 V
to 15 V DC or for the SPS 1560 from 1V – 15Vm; current limitation is not possible. 

A special feature of the models SPS 1525 PFC und SPS 1540 PFC is a fixed voltage
switch on the underside of the device to fix the output voltage to 13.8 VDC. 

Summary of Contents for 51 00 61

Page 1: ...8 Alle Rechte einschlie lich bersetzung vorbehalten Reproduktionen jeder Art z B Fotokopie Mikroverfilmung oder die Erfassung in elektronischen Datenverarbei tungsanlagen bed rfen der schriftlichen G...

Page 2: ...und Netztechnik durch beson dere Kompetenz und permanente Innovation auszeichnet Mit Voltcraft werden Sie als anspruchsvoller Bastler ebenso wie als professioneller Anwender auch schwierigen Aufgaben...

Page 3: ...geschlossenen Verbrauchers darf 25A bei Modell SPS1525 40A bei Modell SPS1540 und 60A bei Modell 1560 nicht berschreiten Das Schaltnetzteil ist in Schutzklasse 1 aufgebaut Es ist nur f r den Anschluss...

Page 4: ...17 14 Fernsteuereingang f r Spannungsregelung VOLTAGE REMOTE 15 Funktionsschalter f r Fernsteuerung ON EIN OFF AUS 16 Schraubklemmbuchse Hochstromausgang Minuspol bis 60A 17 Schraubklemmbuchse Hochstr...

Page 5: ...und Zubeh r geh ren nicht in Kinderh nde In gewerblichen Einrichtungen sind die Unfallverh tungsvorschriften des Verban des der gewerblichen Berufsgenossenschaften f r elektrische Anlagen und Betriebs...

Page 6: ...g auf Die Ausgangsspannung ist ber den Einstellregler 6 von 3V 15V DC bzw beim SPS 1560 PFC von 1V 15Veinstellbar eine Strombegrenzung ist nicht m glich Als Besonderheit besitzen die Modelle SPS 1525...

Page 7: ...Anschlussbuchsen Beim Schaltnetzteil SPS 1560 PFC k nnen an der Vorderseite bis zu 5A und an der R ckseite bis zu 60A abgenommen werden Die K hlung des Netzger tes bernimmt ein temperaturgesteuerter L...

Page 8: ...l besitzt eine automatische Spannungsregelung f r den Hoch stromausgang Dazu werden zwei separate Messleitungen parallel zu den Anschlus sleitungen angeschlossen Auf diesen beiden Messleitungen wird d...

Page 9: ...u e au dos Visser la bague de fixation ext rieure R gler la tension de la source externe sur z ro 11 Zum Anschluss gehen Sie wie folgt vor Verbinden Sie immer erst die Versorgungsleitungen vom Netztei...

Page 10: ...e den Schalter in Position OFF AUS 37 Fonction SENSE uniquement pour SPS 1560 PFC Le r seau d alimentation dispose d un r glage automatique de tension pour la sortie courant lev Pour cela deux c bles...

Page 11: ...om mateurs jusqu 5A limitation de courant automatique sur les douilles de protec tion avant et jusqu 60A sur la face arri re via les bornes courant lev La consommation de courant des consommateurs rac...

Page 12: ...er la d sactivation de l appareil par inadvertance Le DC Raccordement secondaire s effectue au moyen de deux douilles de bornes vis color s Le r seau d alimentation SPS 1560 PFC peut pr lever maximum...

Page 13: ...t avec une tension vibreuse et ils redonnent un grand spectre des ondes harmoniques sur le cordant d alimentation qui peuvent d ranger d autre part les autres appareils Pour retenir ces ondes harmoniq...

Page 14: ...er port e de main des enfants Dans les installations industrielles il convient d observer les consignes de pr ven tion des accidents relatives aux installations et moyens d exploitation lectriques dic...

Page 15: ...d un non respect des pr sentes instruc tions a pour effet d annuler la garantie De m me le constructeur n assume aucune responsabilit en cas de dommages mat riels ou corporels r sultant d une utilisa...

Page 16: ...es mati res Introduction 30 Table des mati res 31 Utilisation conforme 31 La mise en service 35 G n ralit s 35 Raccordement d un cordon secteur 35 R gelage de la tension de sortie souhait e 35 R glage...

Page 17: ...ltage switch for 13 8V on the underside of the device only for the 1525 PFC and 1540 PFC 6 Adjustment control fort he output voltage 7 Overload indicator lights up in red 8 3 digit LED display for out...

Page 18: ...may still be charged even if the device has been dis connected from all voltage sources Do not switch the switched mode mains power supply on immediately after it has been taken from a cold to a warm...

Page 19: ...o human beings or animals If you have reasons to assume that safe operation is no longer possible immedia tely take the device out of operation and secure it against inadvertent operation Reasons to a...

Page 20: ...ure that there are no consumers connected to the mains power supply Switch on the mains power supply at the power switch 1 The power indicator 2 should light up Now use the DC control 6 to set the des...

Page 21: ...he fixed voltage slide the wiper switch to the opposite direction CAUTION Only change the setting when no consumers are connected Verify the operating voltages of the consumers first Connecting a Cons...

Page 22: ...cross section of at least 22AWG 0 34mm2 through the metal sleeve from the rear Solder these three cables firmly and carefully to the soldering lugs no 1 no 2 and no 3 of the black contact jacks 25 Ma...

Page 23: ...geschlossenen Verbrauchers darf 25A bei Modell SPS1525 40A bei Modell SPS1540 und 60A bei Modell 1560 nicht berschreiten Das Schaltnetzteil ist in Schutzklasse 1 aufgebaut Es ist nur f r den Anschluss...

Page 24: ...17 14 Fernsteuereingang f r Spannungsregelung VOLTAGE REMOTE 15 Funktionsschalter f r Fernsteuerung ON EIN OFF AUS 16 Schraubklemmbuchse Hochstromausgang Minuspol bis 60A 17 Schraubklemmbuchse Hochstr...

Page 25: ...und Zubeh r geh ren nicht in Kinderh nde In gewerblichen Einrichtungen sind die Unfallverh tungsvorschriften des Verban des der gewerblichen Berufsgenossenschaften f r elektrische Anlagen und Betriebs...

Page 26: ...g auf Die Ausgangsspannung ist ber den Einstellregler 6 von 3V 15V DC bzw beim SPS 1560 PFC von 1V 15Veinstellbar eine Strombegrenzung ist nicht m glich Als Besonderheit besitzen die Modelle SPS 1525...

Page 27: ...Anschlussbuchsen Beim Schaltnetzteil SPS 1560 PFC k nnen an der Vorderseite bis zu 5A und an der R ckseite bis zu 60A abgenommen werden Die K hlung des Netzger tes bernimmt ein temperaturgesteuerter L...

Page 28: ...l besitzt eine automatische Spannungsregelung f r den Hoch stromausgang Dazu werden zwei separate Messleitungen parallel zu den Anschlus sleitungen angeschlossen Auf diesen beiden Messleitungen wird d...

Page 29: ...u e au dos Visser la bague de fixation ext rieure R gler la tension de la source externe sur z ro 11 Zum Anschluss gehen Sie wie folgt vor Verbinden Sie immer erst die Versorgungsleitungen vom Netztei...

Page 30: ...e den Schalter in Position OFF AUS 37 Fonction SENSE uniquement pour SPS 1560 PFC Le r seau d alimentation dispose d un r glage automatique de tension pour la sortie courant lev Pour cela deux c bles...

Page 31: ...om mateurs jusqu 5A limitation de courant automatique sur les douilles de protec tion avant et jusqu 60A sur la face arri re via les bornes courant lev La consommation de courant des consommateurs rac...

Page 32: ...er la d sactivation de l appareil par inadvertance Le DC Raccordement secondaire s effectue au moyen de deux douilles de bornes vis color s Le r seau d alimentation SPS 1560 PFC peut pr lever maximum...

Page 33: ...t avec une tension vibreuse et ils redonnent un grand spectre des ondes harmoniques sur le cordant d alimentation qui peuvent d ranger d autre part les autres appareils Pour retenir ces ondes harmoniq...

Page 34: ...er port e de main des enfants Dans les installations industrielles il convient d observer les consignes de pr ven tion des accidents relatives aux installations et moyens d exploitation lectriques dic...

Page 35: ...d un non respect des pr sentes instruc tions a pour effet d annuler la garantie De m me le constructeur n assume aucune responsabilit en cas de dommages mat riels ou corporels r sultant d une utilisa...

Page 36: ...es mati res Introduction 30 Table des mati res 31 Utilisation conforme 31 La mise en service 35 G n ralit s 35 Raccordement d un cordon secteur 35 R gelage de la tension de sortie souhait e 35 R glage...

Page 37: ...ltage switch for 13 8V on the underside of the device only for the 1525 PFC and 1540 PFC 6 Adjustment control fort he output voltage 7 Overload indicator lights up in red 8 3 digit LED display for out...

Page 38: ...may still be charged even if the device has been dis connected from all voltage sources Do not switch the switched mode mains power supply on immediately after it has been taken from a cold to a warm...

Page 39: ...o human beings or animals If you have reasons to assume that safe operation is no longer possible immedia tely take the device out of operation and secure it against inadvertent operation Reasons to a...

Page 40: ...ure that there are no consumers connected to the mains power supply Switch on the mains power supply at the power switch 1 The power indicator 2 should light up Now use the DC control 6 to set the des...

Page 41: ...he fixed voltage slide the wiper switch to the opposite direction CAUTION Only change the setting when no consumers are connected Verify the operating voltages of the consumers first Connecting a Cons...

Page 42: ...cross section of at least 22AWG 0 34mm2 through the metal sleeve from the rear Solder these three cables firmly and carefully to the soldering lugs no 1 no 2 and no 3 of the black contact jacks 25 Ma...

Reviews: