background image

These  operating  instructions  are  published  by  Conrad  Electronic  SE,  Klaus-Conrad-Str.  1,  

D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, 

or the capture in electronic data processing systems require the prior written approval by the editor. 

Reprinting, also in part, is prohibited. 
These  operating  instructions  represent  the  technical  status  at  the  time  of  printing.  Changes  in 

technology and equipment reserved.

© Copyright 2013

 by Conrad Electronic SE. 

V2_0813_02-JH

fig. 2

6.  Use a Phillips screwdriver to loosen the four screws of the terminal block box cover and 

then remove the cover (fig. 2).

7.  Loosen the two screws of the mains cable’s safety gate and then remove the safety gate 

(fig. 2).

8.  Guide the mains cable through the round opening in the terminal block box and connect the 

mains cable with the terminal block inside the terminal block box:
Brown cable = L
Blue cable = N
Green/yellow cable = PE/ground wire, grounding symbol

The  ground  wire  must  be  connected  to  the  terminal  block  under  all 

circumstances.

If the product is serving as a replacement for an existing light and there is 

no ground wire, do not install the product. First install the appropriate supply 

leads.
If no ground wire is connected, there will be voltage applied to the metal 

product housing in the event of an error. This poses a risk of fatal injury due 

to electric shock!

Make sure that the cables are not bare for too long as this may cause short-

circuiting.
Make sure that all screw connections on both sides of the terminal block 

are tight.

9.  Reinstall the safety gate and then attach it using the two screws.
10. Close the terminal block box and make sure the rubber sealing is positioned properly.
11. Put the terminal block bracket and the excess length of the mains cable into the lamp 

housing.

Make sure that the cables are not squeezed, bent or damaged in any other 

way. Do not exert any force when installing the product.

12. Attach the lamp housing to the floor mount bracket using the four short screws.
13. Turn on power to the circuit and check to see if the product works.

If the LEDs do not light up, turn off power to the circuit immediately (turn off 

circuit breaker and/or automatic fuse).
Then check the connection to the power circuit.
In case of doubt, contact a professional (i.e. an electrician).

Maintenance and cleaning

Never use aggressive cleaning agents or chemical solutions, as such would 

damage the housing (discolorations).
Never  point  a  water  jet,  for  example  such  of  high-pressure  cleaning 

equipment, at the lamp, as that could damage the seals!

•  Besides occasional cleaning, the device is maintenance-free.
•  Turn off the product and let it cool down sufficiently before cleaning.
•  Wipe the outer surface with a clean, soft cloth only. In order to remove stubborn staining, you 

may slightly dampen the cloth with warm water.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

a) General

Operating voltage .......................... 220 – 240 V/AC, 50 Hz
Power consumption ....................... 8 W
Illuminant ....................................... 12 x Seoul LED, not dimmable
Colour temperature ........................ 3000 K
Luminous colour ............................ warm-white
Luminous flux ................................ 404 lm
Protection class .............................

I

Protection type ............................... IP54
Operating temperature .................. -30 to +45 ºC
Storage temperature ...................... -30 to +55 ºC
Humidity ......................................... 0 – 90 %
Dimensions (W x H x D) ................ 75 x 850 x 215 mm
Weight ........................................... approx. 1060 g

b) 

LED driver (built-in)

Input voltage .................................. 220 – 240 V/AC, 50 Hz
Input current .................................. 80 mA
Output voltage ............................... 22 V/DC
Output current ................................ 350 mA

Summary of Contents for 43 74 97

Page 1: ...e Netzzuleitung von unten durch die Bodenhalterung Abb 1 5 Befestigen Sie die Bodenhalterung mit den vier langen Schrauben auf dem Montageuntergrund Außenstandleuchte Curve 8 W 850 mm Version 08 13 Best Nr 43 74 97 Bestimmungsgemäße Verwendung Das Produkt eignet sich zur Montage im Außenbereich Schutzart IP54 und dient zur Beleuchtung eines Eingangsbereichs einer Terrasse etc Aus Sicherheits und Z...

Page 2: ...ng korrekt aufliegt 11 Stecken Sie die Klemmleistenhalterung und die Überlänge der Netzzuleitung in das Leuchtengehäuse Stellen Sie sicher dass die Kabel nicht gequetscht geknickt oder auf eine andere Weise beschädigt werden Wenden Sie bei der Montage keine Gewalt an 12 Befestigen Sie das Leuchtengehäuse auf der Bodenhalterung mit den vier kurzen Schrauben 13 Aktivieren Sie die Netzspannung und üb...

Page 3: ...nsert the dowels into the drill holes fig 1 4 Guide the mains cable through the hole from bottom up fig 1 5 Attach the floor mount bracket to the mounting surface using the four long screws Outdoor floor lamp Curve 8 W 850 mm Version 08 13 Item no 43 74 97 Intended use The product is suitable for outdoor installation protection type IP54 and is intended for lighting entrance areas patios etc For s...

Page 4: ... properly 11 Put the terminal block bracket and the excess length of the mains cable into the lamp housing Make sure that the cables are not squeezed bent or damaged in any other way Do not exert any force when installing the product 12 Attach the lamp housing to the floor mount bracket using the four short screws 13 Turn on power to the circuit and check to see if the product works If the LEDs do...

Page 5: ...placez les chevilles dans ceux ci ill 1 4 Faites passer le câble d alimentation du bas dans la plaque du fond ill 1 5 Fixez la plaque du fond avec les quatre vis longues sur la surface de montage Lamped extérieuràpiedCurve8W 850mmVersion 08 13 Nº de commande 43 74 97 Utilisation prévue Le produit est adapté pour un montage à l extérieur indice de protection IP54 et est utilisé pour éclairer une zo...

Page 6: ...n dans le boîtier de la lampe Assurez vous que le câble ne soit pas endommagé par des pincements ou pliages ou tout autre cas qui causerait des dégâts sur celui ci N utilisez pas la force durant l installation 12 Fixez le boîtier de la lampe sur la plaque du fond avec les quatre vis courtes 13 Vérifiez la tension de réseau d alimentation et contrôlez le fonctionnement du produit Si les diodes LED ...

Page 7: ... bodemplaat afb 1 5 Maak de bodemplaat met de vier lange schroeven vast aan het montageoppervlak Vloerlamp voor buiten Curve 8 W 850 mm Versie 08 13 Bestelnr 43 74 97 Bedoeld gebruik Het product is geschikt voor installatie buiten beschermingsgraad IP54 en dient voor het verlichten van entrees terrassen enz In verband met veiligheid en normering CE zijn geen aanpassingen en of wijzigingen aan dit ...

Page 8: ...dichting goed op zijn plaats zit 11 Plaats de aansluitklemmenhouder en de overlengte van de elektrische toevoerkabel in de behuizing van de lamp Verzeker uzelf ervan dat de elektrische snoeren niet geplet geknikt of op andere wijze beschadigd worden Gebruik bij het installeren niet teveel kracht 12 Maak de behuizing van de lamp met de vier korte schroeven vast aan de bodemplaat 13 Schakel de netsp...

Reviews: