b) Solar Module

Dust and dirt on the solar module reduces the output power. Wipe off the solar module with 
a soft, clean cloth from time to time. For stronger contamination, you can moisten the cloth 
slightly with water.
Do not apply too much pressure when cleaning. The glass cover over the solar cells may break, 
which would render the solar module useless. Loss of warranty/guarantee!

Decommissioning, storage

Never leave the product outdoors at outdoor temperatures around or below 0 °C. If ice forms, 
the pump, its extension pipes and the sprinkler attachments may be destroyed. 
Keep the product in a dry and frost-free location after careful cleaning. It must be kept out of 
the reach of children.

Disposal

   At the end of its service life, dispose of the product according to the relevant statu-

tory regulations. 

Technical Data

a) Pump

Operating voltage ................. 12 to 24 V/DC
Conveyor height max. ........... 0.9 m at 12 V/DC  (2.4 m at 24 V/DC)
Max. submersion depth ........ 2 m
Conveyor output max.  ......... 470 l/h at 12 V/DC (740 l/h at 24 V/DC)
Max. water temperature ........ +40 °C
Degree of protection ............. IP68
Cable length ......................... 5 m
Dimensions ........................... 105 x 47 x 74 mm (L x W x H)
Weight .................................. 415 g (incl. cable)

b) Solar Module

Type ...................................... Polycrystalline
Output performance .............. max. 10 W
Nominal voltage .................... 17,28 V/DC
Nominal current .................... 580 mA
Dimensions ........................... 400 x 257 x 27 mm (H x W x D)
Weight .................................. Approx. 1207 g

Summary of Contents for 40 48 16

Page 1: ...Schmutz in die Pumpe was den Filter und den Sprinkleraufsatz innerhalb von Sekunden verstopft und somit eine Funktion verhindert Verbinden Sie den Stecker am Ende des Kabels der Pumpe mit dem Anschlus...

Page 2: ...larzellen brechen k nnte wodurch das Solarmodul unbrauchbar wird Verlust von Gew hrleistung Garantie Au erbetriebnahme Aufbewahrung Lassen Sie das Produkt bei Au entemperaturen um bzw unter 0 C niemal...

Page 3: ...ttom of the pond but e g on a few stones Otherwise a lot of sludge and dirt will get into the pump This clogs the filter and the sprinkler attachment within seconds and thus prevents it from working C...

Page 4: ...solar cells may break which would render the solar module useless Loss of warranty guarantee Decommissioning storage Never leave the product outdoors at outdoor temperatures around or below 0 C If ic...

Page 5: ...in N installez jamais la pompe directement au fond du bassin posez la par ex sur quelques pierres Le cas contraire la pompe aspirerait une grande quantit de boue et d impuret s Cela boucherait le filt...

Page 6: ...ndommager le cache en verre et le module solaire deviendrait inutilisable perte de la garantie ou garantie l gale Mise hors service rangement En pr sence de temp ratures aux alentours de 0 C ou inf ri...

Page 7: ...pomp nooit rechtstreeks op de vijverbodem maar vb op enkele stenen Anders raakt zeer veel modder en vuil in de pomp wat de filter en het sprinklerop zetstuk binnen enkele seconden verstopt en zo zijn...

Page 8: ...ksel boven de fotovolta sche cel len kan breken waardoor de fotovolta sche module onbruikbaar wordt verlies van waarborg garantie Buitenbedrijfstelling opslag Laat het product bij buitentemperaturen r...

Reviews: