background image

This product complies with the applicable national and European requirements.

Intended use

The digital oscilloscope is intended to be used for visualising electrical magnitudes and signals. 

The measuring lead is connected to the oscilloscope via two sockets.
The measured signals can be stored and displayed as a reference. The control of the device is 

performed via VDU-based control menus.
The maximum input variables indicated on the device must never be exceeded. 
A signal generator is also integrated into the instrument.
 Any use other than that described above could lead to damage to this product and involves the 

risk of short circuits, fire, electric shock, etc.
No part of the product may be modified or rebuilt, and the housing must not be opened.
Measurements are not permitted in damp rooms or outdoors, nor under adverse environmental 

conditions.
Unfavourable ambient conditions are:
-  Dampness or high air humidity,
-  dust and combustible gases, vapours or solvents,
-  thunderstorms or similar weather conditions such as strong electrostatic fields, etc.
This quick guide explains the safety measures that should be taken to make working with the 

device as safe as possible. The individual functions of the device are described in more detail 

in the English operating instructions. 
Always observe the safety notes included in the quick guide and operating instructions.
This product complies with the applicable national and European requirements. All names of 

companies and products are the trademarks of the respective owners. All rights reserved.

Package contents

•  Digital oscilloscope
•  2x measuring lead 
•  2x replacement probe 
•  Storage bag
•  Metal stand
• Screwdriver
•  2x 3M sticker
•  Micro-USB cable 
•  Operating instructions in English 
•  Quick guide

  Up-to-date Operating Instructions:    

 

1.  Open produktinfo.conrad.com in a browser or scan the 

displayed QR code.

 

2.  Select document type and language and enter the item 

number into the search field. After submitting the query 

you can download displayed records.

Explanation of symbols

   An exclamation mark inside a triangle refers to important notes in the operating 

instructions.

   The lightning symbol inside a triangle warns of electric shock danger or the impair-

ment of the electrical safety of the appliance.

 

 The “hand” symbol indicates special information and advice on operating the device.

Show / hide menu // Submenu settings

▲ 

Direction button (move your finger up)

◄ 

 Reset settings (press left) // Reduce values (move finger to the left)

◄ 

 Reset settings (press right) // Increase values (move finger to the right)

▼ 

Direction button (move your finger down)

Switch on / off the submenu selection

►II 

 Start / Pause // Save current settings / Screen display (press and hold)

 

On/Off switch

CH A 

Input A

CH B 

Input B

Wave Out 

Output of the frequency generator

Safety instructions

 

 Please read through all the quick guide and operating instructions carefully 

before using of the device, they contain important information on its correct 

operation.

 

 The warranty will be void in the event of damage caused by failure to observe these 

safety instructions! We do not assume any liability for any resulting damage!

 

 We do not assume any liability for personal injuries and material damages caused 

by the improper use or non-compliance with the safety instructions! In such cases, 

the warranty will be null and void.

 

 •   The unauthorised conversion and/or modification of the product is not permitted 

for safety and approval reasons (CE). Do not disassemble the product.

 

 •   This  product  is  not  a  toy.  Therefore,  be  especially  careful  when  children  are 

around. 

 

 •   First, connect the measurement cable to the oscilloscope; then connect the probe 

to the signal measuring circuit to be tested. After finishing the measurements, 

first disconnect the measurement leads from the circuit before you disconnect the 

cable from the oscilloscope.

 

 •   Be especially cautious when dealing with voltages exceeding >30 V AC or >30 V 

DC! Even at these voltages, there is a danger of fatal electric shock if you touch 

electric conductors.

 

 •  Prior to each measurement, check your meter and its measuring leads for 

damage(s). Never take any measurements if the protecting insulation is defective 

(torn, missing, etc.).

 

 •   To eliminate the risks of electric shock, do not directly or indirectly touch the con-

nections/measuring points during measurements.

 

 •   Never touch the probes outside of the marked handling area during a measure-

ment. There is danger of a life-threatening electric shock.

 

 •   Do not use the device shortly before or after a thunderstorm (lightning! / high-

power surges!). Make sure that your hands, shoes, clothing, the floor, the measur-

ing device and/or measuring lines, circuits and circuit components are always dry.

 

 •   Do not use the product inside of rooms, or in poor ambient conditions, where flam-

mable gases, vapours or explosive dust may be present or are present.

 

 •   Do not operate the device near to:

 

  -  strong magnetic or electromagnetic fields

 

  -  transmitting aerials or HF generators.

 

  These can affect the measurement.

 

 •  Only use measuring cables, or equipment, appropriate for the oscilloscope’s 

specifications when taking measurements.

G

  O P E R AT I N G   I N S T R U C T I O N S   www.conrad.com

Touch DIGITAL STORAGE 

OSCILLOSCOPE

Item no. 1386326

Version 12/15

Summary of Contents for 1386326

Page 1: ...rechts dr cken erh hen des Wertes Finger nach rechts bewegen Richtungstaste Finger nach unten bewegen M Auswahl Untermen ein ausschalten II Start Pause aktuelle Einstellungen abspeichern Bildschirman...

Page 2: ...itsgr nden nicht verwendet werden Setzen Sie sich im Falle einer Besch digung mit unserem Kundenservice in Verbindung Aufstellen des Ger tes Stellen Sie das Ger t mit Hilfe des Metallst nders so auf d...

Page 3: ...se values move finger to the right Direction button move your finger down M Switch on off the submenu selection II Start Pause Save current settings Screen display press and hold On Off switch CH A In...

Page 4: ...d com All rights including translation reserved Reproduction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the edi...

Page 5: ...z sur la droite augmentation de la valeur le doigt vers la droite Touche de direction d placer le doigt vers le bas M Sous menu de s lection sur interrupteur II D part Pause enregistrer les param tres...

Page 6: ...duction Toute reproduction quelle qu elle soit p ex photo copie microfilm saisie dans des installations de traitement de donn es n cessite une autorisation crite de l diteur Il est interdit de le r im...

Page 7: ...verhogen van de waarde vinger naar rechts bewegen Richtingstoets vinger naar beneden bewegen M Keuze submenu in uitschakelen II Start pauze huidige instellingen opslaan schermaanwijzingen langer druk...

Page 8: ...rechten vertaling inbegrepen voorbehouden Reproducties van welke aard dan ook bijvoorbeeld fotokopie microverfilming of de registratie in elektronische gegevensverwerkingsapparatuur vereisen de schri...

Reviews: