Chapter 4
Installing the Drive
Page 26
Filepro CFP2107 Series
Installing a CFP2107E
The following paragraphs describe the installation procedure for a 16-bit Single
Connector Attachment (SCA) interface, model CFP2107E drive.
Setting the Drive's Jumpers - CFP2107E
There are no jumpers to set on the model CFP2107E drive since all the
necessary control signals are on the SCA connector. This drive is intended for
applications where the drive is configured at the interface when the drive is
plugged into the interface connector.
Setting the SCSI Bus Address - CFP2107E
The SCSI bus ID of the drive is set by grounding the Interface bus signals shown
below in Table 4-4.
Table 4-4
Setting the SCSI ID
SCSI ID
SCSI ID(0)
SCSI ID(1)
SCSI ID(2)
SCSI ID(3)
0
Open
Open
Open
Open
1
Ground
Open
Open
Open
2
Open
Ground
Open
Open
3
Ground
Ground
Open
Open
4
Open
Open
Ground
Open
5
Ground
Open
Ground
Open
6
Open
Ground
Ground
Open
7
Ground
Ground
Ground
Open
8
Open
Open
Open
Ground
9
Ground
Open
Open
Ground
10
Open
Ground
Open
Ground
11
Ground
Ground
Open
Ground
12
Open
Open
Ground
Ground
13
Ground
Open
Ground
Ground
14
Open
Ground
Ground
Ground
15
Ground
Ground
Ground
Ground