4. LED Description
LED
Color
Function
PWR
Green
Lit when power is available.
FX 100
Green
Lit when FX port speed is 100M.
FX
Link/ACT
Green
Blink
Lit when fiber link is up.
Blink when traffic present.
FDX
Green
Lit when TP port Full Duplex Mode
is enabled.
TP 100
Green
Lit when TP port speed is 100M.
TP
Link/ACT
Green
Blink
Lit when TP link is up.
Blink when traffic present.
5. Technical Specifications
Standards
IEEE 802.3 & IEEE 802.3u
Switching Mechanism
Store & Forward
MAC table
1K Entries
Forward & Filter Rate
(64 Bytes)
10Base-T 14,880 pps
100Base-TX 148,800 pps
LED
Power, FDX, TP 100, TP
Link/Act, Fiber 100, Fiber
Link/Act
Power
DC 5V, 1.6A
Power Consumption
3.5W
Dimensions
71mm (W) x 97mm (D) x
26mm (H)
Temperature
Operating: 0 ~ 50
P
o
P
C
Storage: -20 ~ 60
P
o
P
C
Humidity
5% ~ 90% RH
Certification
FCC Class A, CE
*Please contact us for further reports and updates.
UTP
Cat. 5 UTP cable
Fiber
50/125, 62.5/125, or 100/140
m multi-mode
8.3/125, 8.7/125, 9/125 or 10/125
m single-mode
6. Rear Panel DIP Switch
Pin 1
Pin 2
Pin 3
Pin 4
Off/On
Off/On
Off/On
Off/On
TP Auto-negotiation
TP Speed
TP Duplex
Link Alarm
Enable/Disable
100M/10M
Full/Half
Disable/Enable
The default setting for PIN 1 to PIN 4 is Off.
Please perform Power On reset after modifying the
Dip Switch setting.
7. Link Alarm
Link Alarm allows users to easily identify and diagnose the
linking status. If Link Alarm Dip switch is set to Enable,
UTP and Fiber port can link up only when both linking
conditions are good. In addition, if the fiber or UTP port link
is down during operation, the other port will also be turned
down to alert the user. Setting Link Alarm Dip switch to
Enable provides users transparent link indication between
two network devices interconnected by CVT-100W2X.
If Link Alarm is disabled, the UTP and fiber port will link up
based on their individual linking condition. Furthermore, if
fiber port link is down during operation, it will not turn down
the UTP port link and vice versa.
Fiber Transceiver Information
100M
Wave-Length WDM
TYPE
W2A
(SM-20)
W2B
(SM-20)
W2A
(SM-40)
W2B
(SM-40)
Connector Type
SC
SC
SC
SC
TX Wavelength 1310nm
1550nm
1310nm
1550nm
RX Wavelength 1550nm
1310nm
1550nm
1310nm
Typical Distance
20 Km
20 Km
40 Km
40 Km
Min TX PWR
-14.0dBm -14.0dBm -8.0dBm
-8.0dBm
Max TX PWR
-8.0dBm
-8.0dBm
0dBm
0dBm
Sensitivity
-31.0dBm -31.0dBm -34.0dBm -34.0dBm
Link Budget
17.0 dB
17.0 dB
26.0 dB
26.0 dB
NOTE:
Specifications may change without prior notice.
Contact Information
Connection Technology Systems INC (CTS)
18F-6, No.79, Sec.1, Xintai 5th Rd., Xizhi Dist.,
New Taipei City 221, TAIWAN, R.O.C.
TEL: +886 2 26989661 FAX: +886 2 26989662
E-Mail: [email protected]
CVT-100W2X
10/100BASE-TX to
100BASE-FX Standalone
Media Converter
User’s Guide