4.  LED Description 

LED 

Color 

Function 

PWR  

Green 

Lit when power is available. 

FX 100 

Green 

Lit when FX port speed is 100M. 

FX 
Link/ACT 

Green 
Blink 

Lit when fiber link is up. 
Blink when traffic present. 

FDX 

Green 

Lit when TP port Full Duplex Mode 
is enabled. 

TP 100 

Green 

Lit when TP port speed is 100M. 

TP 
Link/ACT 

Green 
Blink 

Lit when TP link is up. 
Blink when traffic present. 

 

 

5.  Technical Specifications 

Standards 

IEEE 802.3 & IEEE 802.3u

 

Switching Mechanism 

Store & Forward

 

MAC table 

1K Entries

 

Forward & Filter Rate  
(64 Bytes) 

10Base-T  14,880 pps 
100Base-TX  148,800 pps

 

LED 

Power, FDX, TP 100, TP 
Link/Act, Fiber 100, Fiber 
Link/Act

 

Power 

DC 5V, 1.6A

 

Power Consumption 

3.5W 

Dimensions 

71mm (W) x 97mm (D) x 
26mm (H) 

Temperature 

Operating: 0 ~ 50 

P

o

P

C                                    

Storage: -20 ~ 60 

P

o

P

Humidity 

5% ~ 90% RH 

Certification 

FCC Class A, CE 

*Please contact us for further reports and updates. 

UTP 

Cat. 5 UTP cable 

Fiber             

50/125, 62.5/125, or 100/140

m multi-mode 

8.3/125, 8.7/125, 9/125 or 10/125

m single-mode 

 

6.  Rear Panel DIP Switch  

  
Pin 1 
Pin 2 
Pin 3 
Pin 4 

Off/On 
Off/On 
Off/On 
Off/On 

TP Auto-negotiation 
TP Speed 
TP Duplex 
Link Alarm 

Enable/Disable 
100M/10M 
Full/Half 
Disable/Enable 

 
The default setting for PIN 1 to PIN 4 is Off. 

Please perform Power On reset after modifying the 
Dip Switch setting.  

7.  Link Alarm 

Link Alarm allows users to easily identify and diagnose the 
linking  status.  If  Link  Alarm  Dip  switch  is  set  to  Enable, 
UTP  and  Fiber  port  can  link  up  only  when  both  linking 
conditions are good. In addition, if the fiber or UTP port link 
is down during operation, the other port will also be turned 
down  to  alert  the  user.  Setting  Link  Alarm  Dip  switch  to 
Enable provides users transparent link indication between 
two network devices interconnected by CVT-100W2X.

 

 
If Link Alarm is disabled, the UTP and fiber port will link up 
based on their individual linking condition. Furthermore, if 
fiber port link is down during operation, it will not turn down 
the UTP port link and vice versa. 
 
 

Fiber Transceiver Information 

100M 
 
Wave-Length WDM 

TYPE 

W2A 

(SM-20) 

W2B 

(SM-20) 

W2A 

(SM-40) 

W2B 

(SM-40) 

Connector Type 

SC 

SC 

SC 

SC 

TX Wavelength  1310nm 

1550nm 

1310nm 

1550nm 

RX Wavelength  1550nm 

1310nm 

1550nm 

1310nm 

Typical Distance 

20 Km 

20 Km 

40 Km 

40 Km 

Min TX PWR 

-14.0dBm  -14.0dBm  -8.0dBm 

-8.0dBm 

Max TX PWR 

-8.0dBm 

-8.0dBm 

0dBm 

0dBm 

Sensitivity 

-31.0dBm  -31.0dBm  -34.0dBm  -34.0dBm 

Link Budget 

17.0 dB 

17.0 dB 

26.0 dB 

26.0 dB 

NOTE:

 Specifications may change without prior notice. 

 
 

 

 

Contact Information 

Connection Technology Systems INC (CTS)  
18F-6, No.79, Sec.1, Xintai 5th Rd., Xizhi Dist., 
New Taipei City 221, TAIWAN, R.O.C. 
TEL: +886 2 26989661  FAX: +886 2 26989662 
E-Mail: [email protected]

 

 
 

 

 

 

CVT-100W2X 

 

10/100BASE-TX to 

100BASE-FX Standalone 

Media Converter

 

 

 
 
 
 
 
 
 
 
 
 

User’s Guide 

 

Version 3.2

 

 

Reviews: