Power Consumption and Thermals
Current Consumption
Below are some examples of actual measurements taken with the
COM Express Type 10 Mini Carrier
running
in various test setups. Some values will change depending on what COM Express module is installed, please
refer to the module manufactures manual for full details on the current consumption of the particular module
you are using.
Actual Measurements
Amps
Watts
Carrier standalone no module installed, powered ON, with no loads
0.14
1.68
Module Installed
[1]
, single DDI video output, USB keyboard with system sitting
in BIOS
0.72
8.64
Module Installed
[1]
, single DDI video output, all peripherals connected, booted
Linux running, CPU running stress test
1.03
12.36
Note [1] : COM Express Type 10 Module used for measurements - Intel Core N2600 CPU
Thermal Properties
All components on the
COM Express Type 10 Mini Carrier
rare rated to a maximum operating temperature of
-40°C to +85°C. The carrier has been fully tested to run in both extremes in an environmental test chamber
with 125 CFM of airflow.
Below are some thermal images of the carrier running standalone at room temperature with and without a
module installed.
TOP VIEW
BOTTOM VIEW