Boson for FRAMOS
Users Guide
Document: CTIM-00057
Revision: 0.00
Page 24 of 28
Date: 2021-04-06
Camera XVS0 DIP Selection
Boson for FRAMOS implements an 8 position DIP Switch for the selection of different FRAMOS Camera
XVS0 signals. Do not change from defaults.
Function
Description
Location
S1
Type
8 position DIP switch
Jumper for CAN termination and External Reset
Boson for FRAMOS implements a 2 position Jumper for Enabling or Disabling the CAN Termination
Resistor of 120Ω
and a location for external RESET.
Function
Description
Location
J1
Type
Jumper
J1A
CAN Termination Enable/Disable
Populate jumper to enable 120
Ω
termination
J1B
External RESET.
Place jumper to put carrier in
permanent RESET. Or use as a
location to connect an external
push button.