Conlog BEC21 Installation Manual Download Page 8

 

Display Messages 

 

 

 

 
 

 
 
 
 

 
 
 

 
 
 
 

 
 
 
 

 
 
 

 
 
 
 

 
 
 
 

 

 

    

 

 

 

 

    

 

                              

 

  

           

Reason for Abnormal Trip Condition  

  

              

   

   

             

  

 

                

           

 

 

No Credit Available:

 A credit token is 

required to connect the supply 

 

If the meter terminal cover is not fitted 
correctly, the commissioning process 
will not be accepted. 

 

Flashing Bar Graph:

 Press #73# to 

display trip condition 

 

To Commission:

 Press #43# Load will 

connect and tamper will activate. 

Error 
code 

Description 

E01  Meter not initialised - contact Conlog 

E02  Meter not calibrated - contact Conlog 

E03  Internal error - contact Conlog 

E04  No supply voltage present 
E05  Reserved for future use 

E06  Reserved for future use 

E07  Communication error between the meter 

and WCIU (Applicable to split meters only) 

E08  Wireless user interface error - contact 

Conlog (Applicable to split meters only) 

E09  Incompatibility between the meter and 

WCIU (Applicable to split meters only) 

E10  Software error - contact Conlog 

E12  Communication protocol error between 

meter and WCIU (Applicable to split meters 

only) 

E20  Remote disconnection initiated 

 
 

 

 

 
 
 

 
 
 
 

Summary of Contents for BEC21

Page 1: ......

Page 2: ...afety Information 3 Safety and Maintenance Instructions 4 Installation 5 Diagrams and Illustrations 5 Procedure 6 Testing the Meter Installation and Sealing the Device 7 Cabling Specifications 7 Displ...

Page 3: ...ical Contractor No responsibility is assumed by Conlog Pty Ltd for any consequences arising out of the use of this material An installation electrician or electrical contractor is one who has skills a...

Page 4: ...ls are used for the installation Ensure that the meter is installed in a dry location and is not exposed to water or moisture No sharp objects to be used to press the keypad If keypad is damaged pleas...

Page 5: ...iagrams and Illustrations Figure 2 Terminal Cover Remove terminal screw before mounting the meter and insert the terminal screw on to the terminal cover Figure 1 Product Layout Figure 3 Terminals Figu...

Page 6: ...ve supply to L LINE Figure 3 7 Connect the incoming neutral supply to N LINE Figure 3 8 Connect the outgoing live supply to L LOAD Figure 3 9 Connect the outgoing neutral supply to N LOAD Figure 3 10...

Page 7: ...to the serial number printed on the meter label and card to confirm that the numbers match 6 Turn on an appliance or light in the consumer s premises to ensure that the consumer has electricity In so...

Page 8: ...alised contact Conlog E02 Meter not calibrated contact Conlog E03 Internal error contact Conlog E04 No supply voltage present E05 Reserved for future use E06 Reserved for future use E07 Communication...