Technical Details 

The electrical characteristics are /-3.0  percent of the indicated value of Pmax and /-10.0 percent of the indicated values of VmPP, ImPP, Voc and Isc 
under standard test conditions (irradiance of 1000 W/m2, AM 1.5 spectrum and a cell temperature of 25 °C (77 °F)). 
 

Module Type 

Maximum 

Power (P

MPP

Maximum Power 

Voltage (V

MPP

Maximum Power 

Current (I

MPP

Open Circut 

Voltage (V

oc

Short Circut 

Current (I

sc

Maximum System 

Voltage (V) 

Maximum Series 

Fuse Rating (A) 

PH 245P 

245Wp 

29.92V 

8.20A 

37.98V 

8.62A 

1000V 

15A 

PH 250P 

250Wp 

30.30V 

8.27A 

38.19V 

8.65A 

1000V 

15A 

PH 255P 

255Wp 

30.68V 

8.33A 

38.40V 

8.69A 

1000V 

15A 

PH 260P 

260Wp 

31.05V 

8.39A 

38.53V 

8.72A 

1000V 

15A 

PH 265P 

265Wp 

31.43V 

8.46A 

38.72V 

8.75A 

1000V 

15A 

PH 270P 

270Wp 

31.78V 

8.52A 

38.91V 

8.79A 

1000V 

15A 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Document History 
1st version:14th October 2010 
2nd revision:16th December 2010 
3rd revision: 21st March 2011 
4th revision: 26th April 2011 (WEEB addendum) 
5th revision: 26th October 2011 
6th revision: 29th October 2011 (WEEB addendum) 
7th revision: 19th November 2012 
8th revision: 19th November 2012 (Clamping addendum) 
9th revision: 27th August 2013 
10th revision: 27th August 2013 
11th revision: 2nd June 2014 

Installation Manual

 

Conergy  

PH 245-270P

 

 

Summary of Contents for PE 295P

Page 1: ...Conergy PH 245P 270P Solar Module Installation Manual UL Version ...

Page 2: ...fied technicians authorized by Conergy as otherwise the warranty will be voided only components cable plugs mounting parts etc that are suitable for use in photovoltaic systems are used the solar module is not installed near highly flammable gases or vapors because sparks could be generated the solar modules are installed over a fireproof roof covering when installed on a roof artificially concent...

Page 3: ...ording to the latitude of the installation location Request this information from your dealer or find it in the official tables Always mount the solar modules with the same orientation and tilt angle Otherwise special consideration will need to be given to system design and inverter selection Maintain an adequate distance between adjacent solar modules to allow for expansion in case of changing th...

Page 4: ... on the long sides K1 K2 K3 K4 b Clamping on the short side permitted Yes Number of clamps to be used in each case on the short sides 2 Positioning of the clamps on the short sides N1 N2 N3 N4 The clamping elements must not protrude past the edge of the frame on the glass side Make sure the clamping elements do not damage the frame surface or bend the frame 3 3 Electrical installation 3 3 1 Electr...

Page 5: ...o section Grounding Requirements UL 4 Maintenance and care The solar modules are low maintenance modules However Conergy recommends that a visual inspection of the mechanical and electrical connections be performed once a year to detect any damage Dirt on the solar modules reduces the output and the yield If the solar modules are installed with an inclination angle of more than 15 they will genera...

Page 6: ...he module frame see fig 3 1 Avoid contact corrosion when using different metals and observe electro chemical insulation rating As an option UL 467 approved bonding and grounding devices including Burndy formerly WileyElectronics Washer Electrical Equipment Bonding WEEB and similar devices which penetrate the anodized layer of the module frame during installation can also be used for grounding the ...

Page 7: ... 8 62A 1000V 15A PH 250P 250Wp 30 30V 8 27A 38 19V 8 65A 1000V 15A PH 255P 255Wp 30 68V 8 33A 38 40V 8 69A 1000V 15A PH 260P 260Wp 31 05V 8 39A 38 53V 8 72A 1000V 15A PH 265P 265Wp 31 43V 8 46A 38 72V 8 75A 1000V 15A PH 270P 270Wp 31 78V 8 52A 38 91V 8 79A 1000V 15A Document History 1st version 14th October 2010 2nd revision 16th December 2010 3rd revision 21st March 2011 4th revision 26th April 2...

Page 8: ...A Toll Free 888 396 6611 Tel 720 305 0700 info conergy us www conergy us Conergy Canada Headquarters 17815 111 Ave Edmonton AB T5S 2X3 Canada info conergy ca Toll Free 888 489 3701 Tel 780 489 3700 www conergy ca The figures and drawings in these assembly instructions are for illustration only and may differ from reality Conergy reserves the right to make changes to this installation manual withou...

Reviews: