background image

 

1.  Introduction 

1.1.

 

About this installation manual 

1.1.1.

 

Subject of this manual 

This installation manual describes the procedures for installation and electrical 
connection of these solar modules in a grid-connected photovoltaic system. 
Additional solar modules are installed with the same procedures. 

1.1.2.

 

User group 

The manual is intended to be used by the system owner and by qualified 
persons possessing technical skills and basic electrical, electronic and 
mechanical knowledge related to photovoltaic systems. Please retain this 
manual for future reference. 
 

1.2.

 

Standards and technical directives 

The solar modules comply with the following standards: 

ULc/ORD-C1703  &  UL 1703 

 

1.3.

 

Intended use 

The solar modules are designed for use in photovoltaic systems. Any other use 
is considered improper use. These solar modules do not comply with the 
technical regulations for overhead glazing and may not be used for such 
applications. These solar modules are not intended for use in mobile 
applications (e.g. vehicles) or marine applications (e.g. boats). Intended use 
also includes compliance with the specifications stated in this installation 
manual. Conergy shall not be held liable for damages arising from a failure to 
observe and follow the installation manual, particularly the safety instructions 
contained in it, or from any improper use of the product. 
 
 

2.  Safety 

2.1.

 

Responsibilities of the owner/operator 

The system operator has safety-related responsibilities. He must ensure that: 

local codes and other applicable laws concerning required permitting as well 
as installation & inspection requirements, rules and regulations are consulted 
and followed; 

the installation is only carried out by qualified individuals with photovoltaic 
specialist technical knowledge and basic knowledge of mechanical 
engineering; 

the electrical connection is only established by qualified persons; 

Persons commissioned to perform the work can evaluate their assigned 
tasks and recognize possible risks; 

those commissioned to perform the work are familiar with the system 
components; 

the installation manual is made available during the installation; 

the installation manual, and in particular the safety instructions, have been 
read and understood by the relevant personnel before installation; 

suitable lifting gear and tools are used for the installation; 

if replacements are required, only Conergy components are used and repairs 
are only carried out by qualified technicians authorized by Conergy, as 
otherwise the warranty will be voided;  

only components (cable, plugs, mounting parts, etc.) that are suitable for use 
in photovoltaic systems are used; 

the solar module is not installed near highly flammable gases or vapors 
because sparks could be generated; 

the solar modules are installed over a fireproof roof covering when installed 
on a roof; 

artificially concentrated sunlight shall not be directed on the module or panel; 

the junction box and the cable are not exposed to direct sunlight for long 
periods of time, 

the solar module is not in direct contact with water or exposed to moisture for 
long periods of time, 

the solar module is not subjected to any extreme chemical loads (e.g. 
emissions from production operations), 

the solar module is not subjected to mechanical loads higher than the 
approved levels, 

the solar module is only used in the specified ambient temperature range, 

no paint, coatings or adhesives are applied to the solar module; 

the solar module is not dismantled and none of the parts provided on delivery 
are removed. 

the solar modules are only transported in their original packaging. 

 

2.2.

 

Basic safety instructions 

The following safety instructions and warnings form an essential part of this 
installation manual and are of fundamental importance when handling this 
product. 

Make allowance for the loads that these modules may generate for the entire 
structure. 

To avoid damage (e.g. broken glass) do not leave solar modules unsecured. 

Check the mechanical integrity of the solar modules prior to installation. Only 
use undamaged solar modules. 

Only use mounting systems recommended by Conergy that can withstand 
the expected loads for snow, wind, etc. 

Make sure no other system components impair the mechanical or electrical 
function of the solar modules. 

Only work in dry conditions with dry solar modules and dry tools. 

Do not drill any holes into the module frame or the glass surface and do not 
perform any welding work on or in the direct vicinity of the solar module. 

To avoid burns do not touch solar modules under load without wearing 
protective gear, i.e. insulating gloves, protective eyewear, etc. 

Never touch solar modules with cracked or broken cover glass or damaged 
back sheets without wearing gloves. 

Comply with the applicable occupational health and safety regulations (e.g. 
regarding protective clothing). 

Carry out the entire installation in the presence of a second person so that 
assistance can be provided in case of an accident. 

Keep a copy of this installation manual in the immediate vicinity of the 
system. 

 

 

1.  Introduction 

Installation Manual

 

Conergy  

PH 245-270P

 

 

Summary of Contents for PE 295P

Page 1: ...Conergy PH 245P 270P Solar Module Installation Manual UL Version ...

Page 2: ...fied technicians authorized by Conergy as otherwise the warranty will be voided only components cable plugs mounting parts etc that are suitable for use in photovoltaic systems are used the solar module is not installed near highly flammable gases or vapors because sparks could be generated the solar modules are installed over a fireproof roof covering when installed on a roof artificially concent...

Page 3: ...ording to the latitude of the installation location Request this information from your dealer or find it in the official tables Always mount the solar modules with the same orientation and tilt angle Otherwise special consideration will need to be given to system design and inverter selection Maintain an adequate distance between adjacent solar modules to allow for expansion in case of changing th...

Page 4: ... on the long sides K1 K2 K3 K4 b Clamping on the short side permitted Yes Number of clamps to be used in each case on the short sides 2 Positioning of the clamps on the short sides N1 N2 N3 N4 The clamping elements must not protrude past the edge of the frame on the glass side Make sure the clamping elements do not damage the frame surface or bend the frame 3 3 Electrical installation 3 3 1 Electr...

Page 5: ...o section Grounding Requirements UL 4 Maintenance and care The solar modules are low maintenance modules However Conergy recommends that a visual inspection of the mechanical and electrical connections be performed once a year to detect any damage Dirt on the solar modules reduces the output and the yield If the solar modules are installed with an inclination angle of more than 15 they will genera...

Page 6: ...he module frame see fig 3 1 Avoid contact corrosion when using different metals and observe electro chemical insulation rating As an option UL 467 approved bonding and grounding devices including Burndy formerly WileyElectronics Washer Electrical Equipment Bonding WEEB and similar devices which penetrate the anodized layer of the module frame during installation can also be used for grounding the ...

Page 7: ... 8 62A 1000V 15A PH 250P 250Wp 30 30V 8 27A 38 19V 8 65A 1000V 15A PH 255P 255Wp 30 68V 8 33A 38 40V 8 69A 1000V 15A PH 260P 260Wp 31 05V 8 39A 38 53V 8 72A 1000V 15A PH 265P 265Wp 31 43V 8 46A 38 72V 8 75A 1000V 15A PH 270P 270Wp 31 78V 8 52A 38 91V 8 79A 1000V 15A Document History 1st version 14th October 2010 2nd revision 16th December 2010 3rd revision 21st March 2011 4th revision 26th April 2...

Page 8: ...A Toll Free 888 396 6611 Tel 720 305 0700 info conergy us www conergy us Conergy Canada Headquarters 17815 111 Ave Edmonton AB T5S 2X3 Canada info conergy ca Toll Free 888 489 3701 Tel 780 489 3700 www conergy ca The figures and drawings in these assembly instructions are for illustration only and may differ from reality Conergy reserves the right to make changes to this installation manual withou...

Reviews: