background image

CGU 04i   DESCRIPTION 

 2. Description of the communication module CGU 04i 

 2.1. General 

GSM/GPRS communication module CGU 04i is a wireless data transmission device. 

The communication module is one of the basic elements of AGNES GPRS system. 
The system AGNES characteristics are described in reference 

[1]

. GSM-GPRS infrastructure 

is used for the wireless communication as a line layer. ARNEP protocol is implemented above 
the line layer. The protocol ARNEP is described in reference 

[2]

. On its basis the modules 

create virtual private data network where data can be transferred between user devices via 

any protocols. 

One may simply imagine the CGU 04i module as a protocol converter between 

the user device (PLC automatic, PC, data terminal, etc.) and GSM-GPRS infrastructure 
of a mobile network operator, it provides the user with possibility to communicate simply 
between all the systems. Apart from data transfers via GPRS the CGU 04i module enables 

SMS. 

The radio component GSM-GPRS is built in the CGU 04i module, consisting module 

Cinterion. 

GSM-GPRS module CGU 04i is controlled by communication 32-bit microprocessor. 

It ensures GSM-GPRS communication, data transfer on serial user interfaces and a number 
of diagnostic and service features. CGU 04i module in the basic version has one serial user 

interface (communication port) RS232, one interface for direct connection of inputs 
and outputs (CIO) for data collection and technological process management and one optional 
user interface (RS232, RS422, RS485, M-BUSD, CNT). It is possible to set transfer 
parameters and communication protocol for each user interface separately. As a result you 
may communicate with various user interfaces using different communication protocols on 

serial interface. 

 2.2. Examples of possible applications 

 Security 

systems 

 Telematics 

 Telemetry 

  Vending and dispenser machines 

 

 2.3. Compatibility with other Conel company modems 

Regarding the communication and data transfers the CGU 04i module is compatible 

with the older CGU 04 type (or CGU 02). This means it is possible to combine both types 
in one network and simply extend an existing network of CGU 04 (CGU 02) modules 

with new communication points using CGU 04i modules. CGU 04i provides some features not 
included in the older CGU 04 type. 

User and industrial communication protocol implemented on serial interfaces are 

compatible with the protocols used for Conel radio modems (e.g. CDA 70). Thus you may 
establish complex combined data networks consisting of both radio and GPRS modems. 

Summary of Contents for CGU 04i

Page 1: ...GPRS modem CGU 04i USER S GUIDE Declared system ISO 9001 2009...

Page 2: ...2 Connector PORT2 CNT 20 2 7 5 CIO connector 21 2 7 6 PWR supply connector 23 2 8 Antenna connection 25 2 9 Technical specifications of port 2 25 2 10 CGU 04i settings 28 2 11 Service cable 28 2 12 S...

Page 3: ...g CIO signals to user device 49 6 REFERENCES 51 7 LINKS TO RELATED PRODUCTS OF THE MANUFACTURER 51 7 1 Systems 51 7 2 Protocols 51 7 3 Software 51 7 4 Products 51 8 PRODUCT DISPOSAL INFORMATION 52 9 C...

Page 4: ...Caution The SIM card could be swallowed by small children Voltage at the feed connector of the communication module must not be exceeded Do not expose the communication module to extreme conditions P...

Page 5: ...ransfer on serial user interfaces and a number of diagnostic and service features CGU 04i module in the basic version has one serial user interface communication port RS232 one interface for direct co...

Page 6: ...ocesses simultaneous tasks Thus parallel operation of all external interfaces of the communication module is maintained The microprocessor is connected through serial interface to MC39i OEM module and...

Page 7: ...mA Reading and control of I O signals is possible from the remote CGU 04i module or any serial user interface Simple technological interface can be created by configuration of two CGU 04i modules wher...

Page 8: ...protocol directly by the customer In case of M BUS expansion board installed and when chosen protocol is not M BUS or M BUS TCP then sent data will be returned back to the device If e g LINE protocol...

Page 9: ...ception 2 x Time slot max 42 8 kb s 4 x Time slot max 85 6 kb s Temperature range Function Storage 20 o C to 55 o C 40 o C to 85 o C Supply voltage 10 to 30 V DC Consumption GPRS TX GPRS on line GSM s...

Page 10: ...ther with PWR station activation failed Inverse flashing to PWR no DNS connection Off GSM GPRS communication established Flashes dimly GPRS transmission or reception z Serial connection Establishment...

Page 11: ...panel The two PORT1 and PORT2 optional connectors are for user interfaces The fourth PWR connector is for supply adapter connection Antenna is connected to the last ANT connector There is RJ45 CIO con...

Page 12: ...Input 2 CTS Clear To Send Output 3 DTR Data Terminal Ready Input 4 DSR Data Set Ready connected to 4 V through 330 Ohm Output 5 GND GROUND signal ground 6 RXD Receive Data Output 7 CD Carrier Detect...

Page 13: ...ion to the CGU 04i z Cable KD2 is connected to serial port PC example COM1 Example of the RS232 equipment connection to the CGU 04i possibility to use all RS232 ports Cable KD 2 Modem CGU 04i PORT1 PO...

Page 14: ...l not active 2 7 3 Connector PORT2 RS485 Panel socket RJ45 Pin number Signal mark Description Direction 1 GND Signal and supply ground 2 GND Signal and supply ground 3 TxRx RS485 B Input Output 4 TxRx...

Page 15: ...an 10m it is need to use overvoltage protection on the modem side Pin 1 SGDN Pin 2 SGND Pin 3 RS485 Pin 4 RS485 Pin 5 RS485 Pin 6 RS485 Pin 7 12V EXT Pin 8 12V EXT Modem CGU 4i SGND RS485 RS485 Meter...

Page 16: ...Transmit Data Input Output 7 12V EXT External supply 8 12V EXT External supply ATTENTION Power supply is selected on the expansion port RS422 by help of a jumper ref 2 9 If galvanic separation is req...

Page 17: ...ength more than 10 m At RS422 data cable more than 10m it is need to use overvoltage protection on the modem side 1Y 2Y DC Meter SGND TxD TxD RxD RxD Modem CGU 04i Pin 1 SGND Pin 2 SGND Pin 3 RxD Pin...

Page 18: ...nput Output 6 TxRx MBUS A Input Output 7 12V EXT External supply 8 12V EXT External supply BEWARE External supply is for converter MBUSD If galvanic separation is required the converter must have exte...

Page 19: ...more than 10 m If an M BUS data cable more than 10m it is need to use overvoltage protection on the router side DC Meter SGND MBUS MBUS Meter SGND MBUS MBUS Modem CGU 04i Pin 1 SGND Pin 2 SGND Pin 3...

Page 20: ...n Direction 1 BIN0 CNT0 Binary input counter input Input 2 BIN1 CNT1 Binary input counter input Input 3 BIN2 Binary input Input 4 BIN3 Binary input Input 5 GND Signal ground 6 OUT0 Binary output Outpu...

Page 21: ...n collector Input Output 3 I O 3 Input Output analogue or binary input or binary output open collector Input Output 4 12V Output 12V supply of other circuits connected directly to modem supply Output...

Page 22: ...addresses are automatically assigned In the direction from modem the addresses raises uplink 1 2 3 4 and 5 Maximal module number in series is five See reference 4 CIO 2 OpI binary input CIO 2 AnI anal...

Page 23: ...V 5 GND Negative pole of DC supply voltage 6 GND Negative pole of DC supply voltage Note Clamps 1 4 UN and 5 6 GND are in the modem connect for bigger current overload On the power supply connector it...

Page 24: ...ery with present supply monitoring DC supply with backup battery without present supply monitoring DC Modem CGU 04i Pin 1 UN Pin 2 NC Pin 3 INAC Pin 4 UN Pin 5 GND Pin 6 GND DC Modem CGU 04i Pin 1 UN...

Page 25: ...Emission EN 55022 B Immunity ETS 300 342 Safety EN 60950 M BUS specifications SN EN 1434 Max devices each 1 5 mA 30 Max operating bus current 60 mA Overload protection 100 mA Short circuit strength p...

Page 26: ...s required jumpers J2 and J3 must be connected to pins 2 3 Internal power supply is made by connecting pins 1 2 with jumpers J2 and J3 Interface behavior of module Expansion port RS485 RS422 can be ma...

Page 27: ...x bit rate 230400 bps Max overvoltage 30 V Max total cable length 300Bd 200nF km 20 m for product Expansion port CNT Expansion port CNT Power supply Internal Sleep 100 A counter is functional Operatio...

Page 28: ...ngs but service interventions in the data network as well The basic setting of the radio modem is in 5 Data cable KD 2 CGU 04i module settings can be done remotely via GPRS Remote configuration access...

Page 29: ...RJ45 connectors for data cables and CIO connection 3 Compliance certificate 4 Complaint procedure 5 Warranty 6 User manual 2 13 Additional accessories 1 Supply adapter 2 AO AGSM FME V antenna 3 Modul...

Page 30: ...CGU 04i DESCRIPTION 30 2 14 Assembly procedure CGU 04i module is designed as a standard for 1 Assembly to a panel using the through holes Through hole for assembly...

Page 31: ...CGU 04i DESCRIPTION 31 2 DIN 35 mm rail assembly using plastic grips 3 To be put on a worktop...

Page 32: ...s to switch board the following it is not need have no examination immunity or issues in connection with EMC according to EN 60439 1 A1 For compliance of EN 60439 1 A1 specification it is necessary ob...

Page 33: ...es can be maximum 1 5 m if length of data cables exceeds 1 5 m or in the event of the cable leads towards the switch board we recommend to use fit over voltage protectors surge suppressors with data c...

Page 34: ...r correct function of the modem we recommend to use in switch board earth bonding distribution frame for grounding of power supply of modem data cables and antenna z the circuit diagram of the modem i...

Page 35: ...g Trade name Type name Supply Other Expansion port RS232 XC 232 Internal from module CGU 04i Expansion port RS485 RS422 XC 485 422 External or internal Round variation RS 485 422 it is possible choose...

Page 36: ...CGU 04i DESCRIPTION 36 2 19 Expansion ports labels...

Page 37: ...et own IP address of the SIM card By this is faster registration to the network some operators not support this function Direct IP address x x x x Parameter sets direct IP address on which will be sen...

Page 38: ...with Global DNS server Modem which isn t right activated isn t accessible from any other modem in network and isn t able send any data to other modem itself In this case the modem isn t able communica...

Page 39: ...r disconnection 0 up to 255 s The modem checks CTS control signal from module If the CTS signal is inactive after this timeout the GPRS connection is inactive and will be new log in to the GPRS Acknow...

Page 40: ...n the GSM registration drop is longer than set this parameter the modem try establish new connection Minimal successful GPRS connect time 0 up to 65535 s When three successful GPRS connect time are sm...

Page 41: ...tored to the journal Log COM ports YES NO When this parameter is set to YES than COM information are stored to the journal Log PPP protocol YES NO When this parameter is set to YES than PPP informatio...

Page 42: ...transfer statistic If number of lost packet is low signal quality is good 3 2 Good quality GPRS requirements z serving cell signal better than 90dBm z adjacent cell signal below 12dB to serving cell...

Page 43: ...BCCH carrier in dBm PLMN PLMN ID code LAC location area code cell cell ID NCC PLMN colour code BCC base station colour code PWR maximal power level used on RACH channel in dBm RXLev minimal receiving...

Page 44: ...CN Absolute Frequency Channel Number of the BCCH carrier rs RSSI value 0 63 RSSI Received signal strength indication dBm Receiving level in dBm PLMN PLMN ID code BCC Base Station colour code C1 coeffi...

Page 45: ...bottom part position 3 and carried out box top part position 2 the expansion port PORT2 position 6 connect to connector J3 see below of the router B CGU 04i motherboard position 1 from TOP side Expan...

Page 46: ...scription Number 1 Modem CGU 04i motherboard 1 2 CGU 04i box top part 1 3 CGU 04i box bottom part 1 4 CGU 04i rear head 1 5 CGU 04i front head 1 6 Expansion port 1 7 Distant columns for expansion port...

Page 47: ...checked every 100 ms from the analogue input transferred to digital ten bit value and adjusted by calibration constant The value is further average computed according to user interface and saved in th...

Page 48: ...30 V The signal is protected against overvoltage by a protection element that blocks voltage in excess of 16 V INAC is designed for measuring of network supply voltage presence The change of the valu...

Page 49: ...ly connector see the supply connector description It is connected as universal I O signal outputs This is an open collector that switches PWRSV signal to the ground GND The output is controlled by a r...

Page 50: ...Binary input One galvanically separated digital input for AC DC signals up to 30 V on high voltage brackets up to 350 V It includes bipolar optoelement that enables processing both input signal polar...

Page 51: ...e are another links on Cinterion company website www cinterion com 7 1 Systems AGNES Advanced GPRS Network System represents a solution for private data network structures for industrial applications...

Page 52: ...ctronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled A...

Page 53: ...the moment of purchase Caution The vendor is not responsible for keeping default settings or data saved in the subject of the complaint The customer is obliged to clarify the defect or how it is disp...

Page 54: ...quire remedy through an extra warranty repair under the conditions the device shall be returned to him her after he she pays the demonstrable cost of expert assessment The guarantee does not cover def...

Page 55: ...WARRANTY 55 10 Warranty Device type Serial number Guarantee period months Vendor Date of purchase Seal of the vendor...

Page 56: ...tration Complaint protocol number Date of reception of the device in repair shop Date of finished repair Number of repair sheet Warranty repair YES NO YES NO YES NO YES NO YES NO New serial number of...

Reviews: