CGU 04i DESCRIPTION
37
2.20. Basic parameters description
For monitoring of status, configuration and administration of the modem is RADWIN
program
[3]
. In right under main menu is function list where is possible choice Configuration
(Ctrl + F1). Next table describes parameters of the tap Basic. Ports description is depend on
used protocol. Protocols description is possible to get from Conel Company.
Parameter name
Set value range
Parameter description
Module serial number
---
Modem serial number information.
GPRS – access point
name
text
Defines network domain, which is accessible
from individuals modems. Every SIM card
in modem is set on the APN of the mobile
operator. In the case of private APN (network
domain) is by this parameter ensure privacy
and secured communication against jam
and system break. APN (domain) assign
mobile operator or Conel company.
GPRS – own IP
address
x.x.x.x
This parameter set own IP address of the
SIM card. By this is faster registration to the
network, some operators not support this
function.
Direct IP address
x.x.x.x
Parameter sets direct IP address on which
will be send all data when the parameter
GPRS – all direct
is set .
Direct IP port
0 up to 65535
Parameter sets direct IP port on which will be
send all data when the parameter
GPRS –
all direct
is set.
GPRS – all direct
YES/NO
If this parameter is set to
YES
than all data
will be send to the direct station. The direct
station is defined by parameters
Direct IP
address
and
Direct IP port
. In this case
in network isn't any routing.
GPRS – global DNS
IP address
x.x.x.x
It is need to configure in case when
in the network is Global DNS server.
It monitors network failure and stations
operation. The IP address of global DNS
server would has been accessible and static.
GDNS stores informations about route tables
from all networks under one domain. GDNS
got informations from LDNS, eventually from
modems. GDNS has to be only one in all
APN (domain).
Network address x
---
Network address information on particular
port.