background image

Qasair Rangehoods Installation Instructions

7

Heritage

Technical Specification Sheet

H

Wall Mounted

3

310mm

Power Entry Vertical

Light Centres

Light Qty

600mm

600HL-1

LED Light

Conversion

Top/Back  Back/Top

Nightlight

2

Condari Pty Ltd.

Filter Qty

2

Motor Qty

Motor Box /

Flue Width

150mm

Version: C  20/01/2015F

Body Width

Model

600HL-1

Page 1 of 2

Filter Size

272mm

 

x

 

3 5 5 m m

NO

700HL-1

Square

Square

130mm

900HL-1

N/A

YES

125mm

Power Entry Horizontal

PowderKote 

Available

Corner Type

Electrical Connection

YES

Outlet Spacing

900mm

240mm

Cool

1

1

700HL-1

Cool

510mm

2

2

310mm

YES

Junction Box

NO

Junction Box

135mm

210mm

NO

YES

Square

N/A

N/A

272mm

 

x

 

3 5 5 m m

290mm

 

x

 

3 5 5 m m

150mm

Junction Box

Model

900HL-1

YES

YES

1

240mm

Cool

240mm

700mm

2

5 0 0

3 0 0

1 5 0

1 1 0

A v a i l a b l e

 

L e n g t h s :

         

D L E

 

6 0 0 m m

         

D L E

 

9 0 0 m m

         

D L E

 

1 2 0 0 m m

         

D L E

 

1 5 0 0 m m

1 0 6

3 0

M i n i m u m

 

H e i g h t :

   

3 0 0 m m

 

M a x i m u m

 

H e i g h t :

 

1 8 0 0 m m

HERITAGE - H

Summary of Contents for QASAIR 3F

Page 1: ...WALL MOUNT INSTALLATION USER INSTRUCTIONS...

Page 2: ...Qasair Rangehoods Installation Instructions 2...

Page 3: ...ns for Models H Series PYR Instructions for Models 3F SEA SMF CM STA STF IN Instructions for Models BRH LAM BAR MAR MAJ FAS Installation Ideas Operation Details Rangehood Cleaning Filter Cleaning Duct...

Page 4: ...Qasair Wallmount Rangehoods is that they be installed between 700 to 800mm above the highest part of the burner When the Rangehood is installed in a galley or partially enclosed kitchen the Rangehood...

Page 5: ...oved if service is required Additional costs incurred in the removal of wall tiles damage to walls or bench tops are not covered by warranty 4 To reduce the risk of fixing screws coming in contact wit...

Page 6: ...p rivet or screw 14 Carefully lift canopy into position guiding flue through ceiling and feeding power cable through hole in rear of canopy Make sure canopy is sitting correctly on mounting bracket th...

Page 7: ...1 Square Square 130mm 900HL 1 N A YES 125mm Power Entry Horizontal PowderKote Available Corner Type Electrical Connection YES Outlet Spacing 900mm 240mm Cool 1 1 700HL 1 Cool 510mm 2 2 310mm YES Junc...

Page 8: ...375mm YES 272mm x 3 5 5 m m 272mm x 3 5 5 m m 1500HL 2 NO 1200HL 2 YES 150mm Square Version C 20 01 2015F Square 75mm 290mm x 3 5 5 m m 1000HL 2 Junction Box 130mm 100mm NO Square Page 2 of 2 Junctio...

Page 9: ...1 Corner Type N A Filter Qty 3 Motor Qty Light Qty Light Centres Motor Box Flue Width Body Width Model Cool YES 2 PYR 900L 1 1 900mm 270mm 510mm LED Light Nightlight Condari Pty Ltd Junction Box PYR...

Page 10: ...all at the desired height 8 Locate solid fixing point in wall to support hood If there is no solid fixing point it will have to be placed in the wall before proceeding QASAIR recommend at least four 4...

Page 11: ...ote Available Filter Size Conversion Top Back Back Top Page 1 of 2 Motor Box Flue Width Minimum Height H Model Electrical Connection 480mm NO 3F 900L 2 272mm x 3 5 5 m m Version C 20 01 2015F YES 1680...

Page 12: ...Connection PowderKote Available YES Round N A Version C 20 01 2015F Page 2 of 2 N A YES 450mm 3 1200mm 3F 1200L 3 3F 1200L 3 NO Junction Box 272mm x 3 5 5 m m 480mm 1680mm 1680mm 3F 1500L 3 Round Jun...

Page 13: ...A 600L 1 SEA 900L 2 SEA 900L 1 SEA 600L 1 SEA 900L 2 SEA 900L 1 600mm Centre 2 N A 1 Cool YES 1 272mm x 2 7 2 m m NO Junction Box 400mm 1450mm YES 400mm Square 900mm N A 1 Cool YES 2 510mm 3 900mm N A...

Page 14: ...m x 2 7 2 m m 272mm x 2 7 2 m m 1450mm Model Conversion Top Back Back Top 400mm YES 1450mm SEA 1500L 3 Corner Type Electrical Connection Minimum Height H SEA 1500L 2 Condari Pty Ltd Filter Size 648mm...

Page 15: ...tres Corner Type SMF 600L 1 SMF 900L 2 SMF 900L 1 SMF 600L 1 SMF 900L 2 SMF 900L 1 600mm 3 1 0 m m 2 450mm 1 Cool YES 2 272mm x 3 5 5 m m YES Junction Box N A N A YES N A Round 900mm 750mm 1 Cool YES...

Page 16: ...xing Centres Corner Type Version C 20 01 2015F 648mm 4 Condari Pty Ltd Round N A N A Round YES Motor Qty Page 2 of 4 N A YES Nightlight Light Qty 850mm 1000mm SMF 1000L 2 510mm 3 LED Light Light Centr...

Page 17: ...LED Light 816mm YES N A YES Junction Box 272mm x 3 5 5 m m SMF 1500L 2 N A SMF 1800L 3 YES YES YES 2 N A 272mm x 3 5 5 m m 290mm x 3 5 5 m m All thread Fixing Centres PowderKote Available SMF 1800L 3...

Page 18: ...1450mm YES Minimum Height H Maximum Height H YES Powderkote A v a i l a b l e 300mm 1450mm SMF 900L 1 SHROUD YES SMF 1000L 2 SHROUD YES 1450mm 300mm YES 1450mm 300mm YES 300mm 1450mm 1450mm 300mm SMF...

Page 19: ...Height H Corner Type 510mm Condari Pty Ltd 3 All thread Fixing Centres PowderKote Available Filter Size Conversion Top Back Back Top Page 1 of 3 Motor Box Flue Width Minimum Height H Model Electrical...

Page 20: ...ht H All thread Fixing Centres Minimum Height H Corner Type CM 1200L 2 Model 510mm Electrical Connection PowderKote Available YES Round N A Version C 20 01 2015F Page 2 of 3 N A YES 850mm 2 1000mm CM...

Page 21: ...e 3 of 3 YES Powderkote A v a i l a b l e YES Maximum Height H Minimum Height H 1450mm 335mm 335mm 1450mm Model CM 1000L 2 SHROUD 1450mm YES 3 3 5 m m CM 900L 2 SHROUD 3 3 5 m m CM 1200L 2 SHROUD 1450...

Page 22: ...erKote Available Conversion Top Back Back Top Filter Size Condari Pty Ltd Model Electrical Connection LED Light Model Nightlight Filter Qty Light Centres Motor Qty Round Body Width Motor Box Flue Widt...

Page 23: ...ximum Height H Condari Pty Ltd All thread Fixing Centres Corner Type Version E 29 06 2016F 740mm 272mm x 3 5 5 m m STA 900L 2 Page 2 of 3 3 510mm Nightlight Cool 2 403mm 900mm STA 900L 2 2 YES Statesm...

Page 24: ...Corner Type All thread Fixing Centres Electrical Connection Model Filter Size Body Width Motor Box Flue Width LED Light Motor Qty Model Light Qty Light Centres Junction Box 740mm Round YES N A Wall M...

Page 25: ...lter Qty Electrical Connection Conversion Top Back Back Top Model Minimum Height H 740mm YES Junction Box 272mm x 3 5 5 m m STF 900L 2 3 510mm YES N A 1280mm Square N A Square 1280mm N A Junction Box...

Page 26: ...ri Pty Ltd Light Centres Light Qty Nightlight Page 1 of 2 Filter Qty Electrical Connection Conversion Top Back Back Top Model Minimum Height H N A YES R e m o t e S w i t c h i n g 272mm x 3 5 5 m m I...

Page 27: ...g Body Width Motor Box Flue Width Nightlight Motor Qty LED Light Light Qty N A 2 Cool NO 2 N A 3 Cool NO 4 560mm 2 IN 1200L 3 1200mm Model 1200mm IN 1200L 2 Filter Qty 4 Light Centres 560mm Condari Pt...

Page 28: ...jury and damage the hood or stove CAUTION Do not under any circumstances lift from the front of the hood or put any pressure on the front face as you will damage the hood permanently 11 Carefully lift...

Page 29: ...pe BRH 600L 1 BRH 900L 2 BRH 900L 1 BRH 600L 1 BRH 900L 2 BRH 900L 1 600mm 310mm 2 N A 1 Cool YES 2 272mm x 3 5 5 m m NO Junction Box 400mm 1450mm YES 500mm Square 900mm N A 1 Cool YES 2 510mm 3 900mm...

Page 30: ...4 All thread Fixing Centres PowderKote Available Filter Size Conversion Top Back Back Top Page 2 of 2 Motor Box Flue Width Minimum Height H Model Electrical Connection 400mm NO BRH 1000L 2 290mm x 3...

Page 31: ...op Electrical Connection Filter Size Model N A Version B 20 01 2015 F Minimum Height H PowderKote Available All thread Fixing Centres 900mm LAM 900L 2 N A 510mm 2 Cool 3 2 YES Body Width Motor Qty Mot...

Page 32: ...4 All thread Fixing Centres PowderKote Available Filter Size Conversion Top Back Back Top Page 2 of 2 Motor Box Flue Width Minimum Height H Model Electrical Connection 400mm NO LAM 1000L 2 290mm x 3...

Page 33: ...ood 1800mm 2400mm Model BAR 2400 3000L 2 900mm 1000mm 1200mm Model Body Width LED Light 2 Junction Box 550mm Motor Qty 1550 m m YES Cool Cool 2 Filter Size 2400mm 3000mm BAR 1800 2400L 2 900mm 1000mm...

Page 34: ...Fixing Centres Corner Type MAR 900L 1 MAR 1200L 2 MAR 900L 2 MAR 900L 1 MAR 1200L 2 MAR 900L 2 900mm 4 2 2 m m 2 N A 1 Cool YES 2 422mm x 2 7 2 m m NO Junction Box N A N A N A N A Square 900mm N A 2 C...

Page 35: ...thread Fixing Centres Corner Type Version A 01 07 2014F 422mm 4 Condari Pty Ltd Square N A N A Square N A Motor Qty Page 2 of 2 N A N A Nightlight Light Qty N A 1500mm MAR 1500L 3 816mm 5 LED Light Li...

Page 36: ...7 2 m m NO MAJ 900L 2 Square Square 600mm MAJ 1000L 2 600mm N A 1150mm Maximum Height H PowderKote Available Corner Type Electrical Connection N A All thread Fixing Centres 1000mm N A Cool 2 2 MAJ 90...

Page 37: ...mm 4 Motor Box Flue Width Model LED Light Light Centres Filter Qty 500mm Maximum Height H Electrical Connection 800mm 1150mm N A Junction Box Version B 29 11 2014F 1150mm Junction Box 600mm All thread...

Page 38: ...2 Junction Box 700mm Motor Qty 1400 m m YES Cool Cool 2 Filter Size 1200mm FAS 900L 2 N A Conversion Top Back Back Top Motor Box Flue Width 300mm x 5 0 0 m m Square Version C 20 01 2015F Junction Box...

Page 39: ...3 FAN A 22 08 2013 BROWN BLUE BLUE BLACK BROWN M Brewin BLACK BLUE BLUE BROWN BROWN WHITE GREEN WHITE GREEN JUNCTION BOXES CABLES TO REMOTE SWITCHES NOTES 1 IT IS NECESSARY TO PROVIDE AN ON OFF AND A...

Page 40: ...i e single or twin motor models 5 Please refer to Wiring Diagram below for detailed wiring information www condari com au WIRING DIAGRAM For further information please contact Condari Pty Ltd phone 03...

Page 41: ...13 BROWN BLUE BLUE BLACK BROWN M Brewin BLACK BLUE BLUE BROWN BROWN WHITE GREEN WHITE GREEN JUNCTION BOXES CABLES TO REMOTE SWITCHES NOTES 1 IT IS NECESSARY TO PROVIDE AN ON OFF AND A HIGH LOW SWITCH...

Page 42: ...m DL 1 CB Single Motor Duct Length 1200mm Colourbond 105 BD WV H 1 SS Back Draft Wall Vent Single Motor Horizontal 445M2 Stainless Steel 106 VB 1 Vertical Bend Single Motor 90 104 BD WV H 1 Back Draft...

Page 43: ...Single Motor 121 BD 6 7 9 WV R R Back Draft Wall Vent Rear Register Kit to Suit 6 7 900H 112 TT 1 Twisted Transition Single Motor 113 DLE DLE Flue Joiner Single Motor 119 DR 200 45 200 Bend 45 116 TR...

Page 44: ...s Steel 134 WVC V 1 SS Wall Vent Cover Single Motor Vertical 445M2 Stainless Steel 135 6 7 900H SC Spiggot Cap to Suit 6 7 900H 130 CF 6 7 900H Ceiling Flange to Suit 6 7 900H 131 WVC H 1 Wall Vent Co...

Page 45: ...5 150 250 240 I I 110 I I 75 150 250 317 248 318 I I All the above ducting pieces are all made in stainless steel type 445M2 which has a chromium content of 22 which is far greater than marine grade s...

Page 46: ...Wall Vent Twin Motor Vertical 445M2 Stainlerss Steel 209 BD WV V 2 Back Draft Wall Vent Twin Motor Vertical 203 HB 2 Horizontal Bend Twin Motor 90 208 VB 2 45 Vertical Bend Twin Motor 45 207 VB 2 Ver...

Page 47: ...250 300 Twin Motor Transition 250SQ to 300 219 DR 300 90 300 Bend 90 225 HB 250 45 Horizontal Bend 250SQ 45 226 TMT 250 90 L Duct Deflector 250SQ Left 227 TMT 250 90 R Duct Deflector 250SQ Right 218 D...

Page 48: ...BD RC 250 SQ Back Draft Roof Cowl 250SQ 239 CF 3F 1200 2 Ceiling Flange tp suit 3F 1200 2 240 CF 4F 900 2 Ceiling Flange to Suit 4F 900 2 238 CF 3F 900 2 Ceiling Flange to Suit 3F 900 2 230 BD RC 2 B...

Page 49: ...10 12 1500H 247 WVC 250 SQ SS Wall Vent Cover 250SQ 445M2 Stainless Steel 249 10 12 15H SC Spiggot Cap to Suit 10 12 1500H 253 DD 2V R Duct Director Twin Motor Vertical Right 254 EV DL 2 Eave Vent to...

Page 50: ...l 300 445M2 Stainless Steel 263 FRC 300 SS Fire Rated Roof Cowl 300 445M2 Stainless Steel WALL VENT 265 FRWV V 2 SS Fire Rated Wall Vent Twin Motor Vertical 445M2 Stainless Steel 266 FRWV 250 SQ SS Fi...

Page 51: ...rtical Bend Triple Motor 45 305 VB 3 Vertical Bend Triple Motor 90 304 HB 3 45 Horizontal Bend Triple Motor 45 302 DL 3 Triple Motor Duct Length 303 HB 3 Horizontal Bend Triple Motor 90 301 3MT DL 3 T...

Page 52: ...rizontal 445M2 Stainless Steel 319 CH 350 CB Chairmans Hat 350 Colurbond 325 WVC H 3 SS Wall Vent Cover Triple Motor Horizontal 445M2 Stainless Steel 326 WVC V 3 Wall Vent Cover Triple Motor Vertical...

Page 53: ...pic length cover BDWVK H 3 95 95 240 I I 110 I I 250 75 150 210 400 EXTENDED COMPRESSED 248 987 150 250 75 988 I I 334 BD WV K H 3 Kit assembled as one piece Three Single Motor Back Draft Wall Vent Ho...

Page 54: ...ement and minimum noise levels Ducting incorrectly with flexible or smaller diameter ducting will dramatically reduce the air movement and increase the noise level of the rangehood and will void the m...

Page 55: ...ion Instructions 55 7 FA 90L 2 T 8 FA 90L 2 T 9 FA 90L 2 T 10 FA 90L 2 B 11 FA 90L 2 T 12 FA 90L 2 T FA 90L 2 T Rangehood FA 90L 2 T Rangehood FA 90L 2 T Rangehood FA 90L 2 T Rangehood FA 90L 2 T Rang...

Page 56: ...600HL 1 T 700HL 1 T 900HL 1 T 14 600HL 1 T 15 CON 60L 1 T 16 CON 80L 1 T 17 CON 60L 1 T 18 CON 80L 2 T CON 80L 2 T Rangehood CON 60L 1 T Rangehood CON 60L 1 T Rangehood CON 80L 1 T Rangehood 600HL 1 T...

Page 57: ...9 1200HL 2 T 20 LIS 800L 2 T 21 LIS 1000L 2 T 22 3F 900L 2 T 1200L 2 T 23 LIS 500L 1 T 24 LIS 800L 1 T LIS 800L 2 T Rangehood 1200HL 2 T Rangehood LIS 1000L 2 T Rangehood 3F 900L 2 T 1200L 2 T Rangeho...

Page 58: ...ds Installation Instructions 58 25 CON 80L 1 T LIS 1000 2 T 26 LIS 1200L 2 B 1 FA 60L 1 B 2 FA 90L 1 T FA 60L 1 B Rangehood FA 90L 1 T Rangehood LIS 1200L 2 B Rangehood LIS 1000L 2 T Rangehood CON 80L...

Page 59: ...t to about 5 to 6 years life Qasair Rangehoods are made from stainless steel either type 304 or type 316 Type 304 is classified as 18 8 stainless steel Type 316 is classified as 18 10 stainless steel...

Page 60: ...s specifically requested To clean filter regularly by handwashing or placing in a dishwasher at least once a month To turn rangehood off after each use Note Warranty under filter cleaning on page 59 W...

Page 61: ...mega joule rating per burner or a total mega joule rating In practice any barbecue or outdoor cooking appliance over 50 mega joule will need a specially made rangehood with an air movement exceeding...

Page 62: ...this warranty QASAIR Rangehoods are made in Ringwood Australia Tel 61 3 9482 7088 Fax 61 3 9482 7011 Email sales condari com au STANDARD WARRANTY Pleae Note that the Warranty is from the date of inst...

Page 63: ...ANTY Pleae note The installation warranty does not cover the ageing process in a building or any problems due to storm damage Condari Pty Ltd provides an extended warranty from 36 months to 72 months...

Page 64: ...Qasair Rangehoods Installation Instructions 64 NOTES...

Page 65: ...Qasair Rangehoods Installation Instructions 65 NOTES...

Page 66: ...Qasair Rangehoods Installation Instructions 66 NOTES...

Page 67: ...Qasair Rangehoods Installation Instructions 67 NOTES...

Page 68: ...423 3503 Fax 07 3282 9122 Email salesqld qasair com au WA Tel 08 9242 5387 Fax 08 9201 0887 Email saleswa qasair com au SA NT Tel 1300 360 563 Fax 03 9482 7011 Email salessa qasair com au TAS Tel 03 9...