![Condari QASAIR 3F Installation & User'S Instructions Download Page 40](http://html1.mh-extra.com/html/condari/qasair-3f/qasair-3f_installation-and-users-instructions_2651814040.webp)
Qasair Rangehoods Installation Instructions
40
REMOTE SWITCHING SPECIFICATIONS
3 FAN, LED and NIGHTLIGHT
1. Wiring to the appliance must comply with State and local regulations.
2. Switching is not provided with this unit. - The order was for the controls to be separate from the unit.
3. You may use any switching to connect the rangehood (e.g. Clipsal switches).
4. All fans must be controlled by at least one ON/OFF and one HI/LO switch.
(i.e. single or twin motor models).
5. Please refer to Wiring Diagram below for detailed wiring information.
www.condari.com.au
WIRING DIAGRAM
For further information, please contact Condari Pty Ltd
phone
: 03 9482 7088
fax
: 03 9482 7011
NOTE: This diagram is for reference only. A qualified elecrician must connect remote
switching to rangehood.
Reflected in this drawing is the most common method of connecting the rangehood.
Be aware that Active voltage must NOT be applied to both the ‘White- High’ or
‘Brown-Low’ wires at the same time. This will cause the fan to fail.
ALL FANS MUST BE CONTROLLED
BY AT LEAST ONE ON/OFF AND
ONE HI/LO SWITCH.
Summary of Contents for QASAIR 3F
Page 1: ...WALL MOUNT INSTALLATION USER INSTRUCTIONS...
Page 2: ...Qasair Rangehoods Installation Instructions 2...
Page 64: ...Qasair Rangehoods Installation Instructions 64 NOTES...
Page 65: ...Qasair Rangehoods Installation Instructions 65 NOTES...
Page 66: ...Qasair Rangehoods Installation Instructions 66 NOTES...
Page 67: ...Qasair Rangehoods Installation Instructions 67 NOTES...