Qasair Rangehoods Installation Instructions
6
INSTALLATION INSTRUCTIONS
• H SERIES
• PYR
1. Remove canopy and flue from boxes and check you have correct model and flue.
2.
Locate centre point of cooktop.
3.
Use level or plumb line to mark centre up to ceiling.
4.
Mark level line for base of canopy 700-800mm above bench 750mm desirable.
5. Check roof space above for wires and obstructions as now is the time to decide on any changes to location due
to immovable obstructions.
6.
Mark flue size on ceiling and cut neat exact hole to pass flue through.
7. For rear ducted models cut hole in wall for vent to pass through.
8.
Fix mounting bracket to wall at desired height.
9.
Remove fan(s) from canopy by removing side fixing bolts and disconnecting electrical plug at flexible connector.
10. Locate solid fixing points on wall and drill holes in rear of canopy to suit. If no solid fixing is available then now is
the time to install fixing points. Four points are recommended with one on each side at top and one on each side
at bottom.
11. Drill hole in rear of unit to pass power connection through where available on wall.
12.
Check flue slides through hole in ceiling.
13. Place canopy flat on floor and fit stainless flue over spigot pushing all the way down for a neat fit. Drill hole in
rear of flue and fix to canopy with pop rivet or screw.
14.
Carefully lift canopy into position, guiding flue through ceiling and feeding power cable through hole in rear of
canopy. Make sure canopy is sitting correctly on mounting bracket then fix to wall through fixing holes with solid
screws. (You may need to place a packer behind canopy if wall is bowed to make the canopy sit correctly).
15. Complete electrical connection to 10 AMP junction box to local electrical authority regulations ensuring power is
turned off during work.
16. Fit ducting to outside or exterior wall vent for rear ducted models. (Seal rear vents onto rear of hood with
silicone). A plumber should seal roof penetration with appropriate flashing. All joins in ducting need to be sealed
with duct tape or silicone and only use approved ducting of the correct size for your canopy.
17.
Fit motor(s) back into canopy with fixing bolts and plug electrical connector in.
18.
Test run hood.
MOUNTING BRACKET
•
Use vertically punched slot for centre line
• Before cutting any holes check ceiling space for structural beams. It may be possible at this point to relocate the
hood position.
The fixing points are prepunched holes in the back of the hood and it may be necessary to drill through the back
of the hood into the wall stud.
Recommended fixing points
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical:
Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Summary of Contents for QASAIR 3F
Page 1: ...WALL MOUNT INSTALLATION USER INSTRUCTIONS...
Page 2: ...Qasair Rangehoods Installation Instructions 2...
Page 64: ...Qasair Rangehoods Installation Instructions 64 NOTES...
Page 65: ...Qasair Rangehoods Installation Instructions 65 NOTES...
Page 66: ...Qasair Rangehoods Installation Instructions 66 NOTES...
Page 67: ...Qasair Rangehoods Installation Instructions 67 NOTES...