• The kitchen furniture must be made of a suffi
ciently heat-resistant material. The materials and used glues must be
resistant to the warming of the unit according to the ČSN EN 60335-2-6 standard. Materials and glues which do not
meet the stated standard may deform or unstick.
Connection in the mains
• Make sure the mains voltage and current protection correspond to the values on the rating plate. We recommend
using a separate outlet circuit with a 16A circuit breaker.
• Use grounded wall outlets only.
• Do not use adapter plugs, connectors or extension cables. They could imply a risk of fi re from overheating.
• The supply cable plug has to be freely accessible even after the installation of the unit.
• Only a qualifi ed expert can perform connection changes.
• Electrical safety of the unit can only be guaranteed if the protective terminal of the unit is connected with the protec-
tive conductor of the mains.
• The manufacturer bears no responsibility for damages caused to people or things as a result of missing or bad
protective connection.
• The power cord must be located so that it does not come into contact with hot parts of the unit and so that it is not
deformed and excessively bent.
When installing the unit, follow these instructions:
1. Remove all the packaging and marketing materials from the unit before the fi rst use.
2. For the required built-in box dimensions see Fig. 4. For the sake of effi
cient air circulation the unit has to be located
according to the dimensions on the pictures and the design of the cabinet must enable air fl ow into its bottom part.
The gap behind the rear wall of the built-in oven must be at least 50 mm.
3. Put the unit on the edge of the cabinet and run the power cord through the rear wall of the cabinet so that its plug
is accessible after installation.
4. Push the unit carefully to the selected place in the cabinet. Be careful not to squeeze the power cord.
5. Attach the unit to the cabinet by screwing four screws in the holes in the front wall. The holes can be seen after
opening of the door (see Fig. 5).
6. Plug the supply cable in the wall outlet.
27
ETV 5060 n
EN
57 5
59 5
56 0
600
850
50
80
250
100
57
0
60 0
56 0
Fig. 4
Fig. 5