PROGRAMMING

 

 
 
 
 
 

The S70 LCD Display  
and operating buttons 

 
 
 
 
 
 
 

LCD illumination.

  The LCD backlight automatically extinguishes after 1 minute of inactivity; 

pressing any button illuminates the backlight. 
 

Setting the time and date.  

In the Smoke Screen Status or Current Time display press and hold 

 for 3 seconds until the date and time are shown with the Day flashing. Use the 

 and 

 buttons 

to change the value.  

   saves a change and moves to the next parameter and 

 returns to the 

previous parameter without saving any change.  Repeated presses of 

 will return the display to 

the higher level menu. 
 

Accessing information and setting variable parameters.

  In the Smoke Screen Status or 

Current Time display press 

 to access the variable parameters.  Use the 

 and 

 buttons to 

scroll through the available functions and 

   to select items to change/view each one as follows: 

 

 

Event Log.

  In the 

“Event Log” display press 

   to show the latest event and the time of 

that event.  Use the 

 and 

 buttons to scroll through the event log.  Pressing 

 will 

return the display to the higher level menu.  Events recorded are as per the Sectio

n “LCD, 

LED and Sound indications”. 
 

 

Setting Smoke Time.

 In the 

“Setting Smoke Time” display press 

   to show the current 

smoke time set.  Use the 

 and 

 buttons to move up and down to select a time between 

5 and 360 seconds in 5 second intervals.  Press 

   to save the new setting and return to 

the higher level menu.  Press 

 to return to the higher level menu without saving changes.  

The delivery Smoke Time Setting is 

“5 seconds”. 

 

 

Setting Fluid Capacity. 

 In the 

“Setting Fluid Capacity” display press 

   to show the 

current fluid capacity set.  Use the 

 and 

 buttons to move up and down to select 500ml, 

1000ml or 5000ml.  Press 

   to save the new setting and return to the higher level menu.  

Press 

 to return to the higher level menu without saving changes.  The delivery Fluid 

Capacity Setting is 

“1000ml”. 

 

 

Setting Temperature.  

This is preset at manufacture and should only be altered by 

Concept Smoke Screen. 
 

 

Setting Smoke Mode.  

In the 

“Setting Smoke Mode” display press 

   to show the current 

smoke mode set.  Use the 

 and 

 buttons to move up and do

wn to select “Turbo Mode” 

or “Normal Mode”.  Press 

   to save the new setting and return to the higher level menu.  

Press 

 to return to the higher level menu without saving changes.  The delivery Smoke 

Mode Setting is “Normal Mode”. 

 

 

18-Mar-2013 

13

30

00 

 

 

 

 

Function / Escape    Up     Down     Enter / Back 

Summary of Contents for Sentinel S70

Page 1: ...Page 1 of 16 SENTINEL S70 INSTALLATION AND OPERATION MANUAL Version 16 December 2013 CAN T SEE IT CAN T STEAL IT ...

Page 2: ...l help Once again thank you for your decision we hope that it s one that never needs to be tested Carl Gibbard Managing Director HOW DOES YOUR SMOKE SCREEN WORK Your Smoke Screen heats a non toxic fluid under pressure to create smoke or more accurately a thermally generated fog that obscures visibility to discourage intruders from entering your premises This fog is very persistent and will stay su...

Page 3: ...ting 6 Nozzle changing 7 Controlling the smoke 7 Circuit board layout 8 Generic connection diagram 8 Energy saving mode 9 Service mode 9 Turbo smoke mode 9 Tamper 9 Fluid management 9 Battery management 10 Programming 11 Operation 12 Testing 12 LCD LED and sound indications 13 Action after every activation 14 Servicing and fluid replenishment 14 FAQ 14 Installer notes 15 ...

Page 4: ...ng schematic STANDARD INSTALLATION A standard installation is configured in the following way The Smoke Screen wall or ceiling mounted in the appropriate location A Hold off PIR or similar device located within the same area as the Smoke Screen providing a confirmation signal to the Smoke Screen to start smoke production A Set command supplied by an Alarm Control Panel or equivalent in the form of...

Page 5: ... Screen is 2 5 metres above the floor over the area to be protected and using a straight nozzle The maximum mounting height above floor level is 3 metres and there should be no obstacle within 1 metre of the smoke output nozzle INSTALLATION PROCEDURE 1 Site the Smoke Screen and fix the bracket to the wall or ceiling as appropriate 2 For wall mounting leave minimum 150mm clearance to ceiling 3 Fast...

Page 6: ...er must fit the Smoke Screen using appropriate fasteners Suspension Kit All M8 Uni strut 1 x 1 metre Threaded bar 2 x 1 metre Fixings 2 x 38mm washer 4 x 25mm washer 6 x full nut 2 x drop in anchor 2 x channel nuts Wall mounting Wall mounting is achieved using a simple wall bracket 1 The bracket should be attached to a suitable wall Use appropriate fixings to secure the bracket to the wall We reco...

Page 7: ... Smoke Screen Alarm Set Trigger and Hold Off that should be connected to clean contacts For the Smoke Screen to produce smoke all 3 sets of connections must be open circuit this can be changed to closed see Invert Trigger Mode in the Programming section If one set of connections is closed circuit then the Smoke Screen is prevented from producing smoke Hence the production of smoke is controlled us...

Page 8: ...tus Output Liqud Status Battery Output Tamper Status Hold Off 100mA Output Tamper Verificatio n Output 100 mA Output Loop tamper pins or select Dip 3 to On if not connected to a device Verification changes state w hen the S70 fires n c and n o show n are w hen the S70 is not firing DC output for additional device Total S70 output must not be greater than 100mA DC output for additional device Total...

Page 9: ... Block C A tamper open state provides only an indication of the event it does not automatically activate the Smoke Screen or prevent it from activation FLUID MANAGEMENT Fluid capacity There are 2 sizes 500ml or 1000ml of transparent bag containing Smoke Fluid for the Smoke Screen It can also be operated with an external 5000ml bottle please contact Concept Smoke Screen if you wish to use this faci...

Page 10: ... second activation The Smoke Screen is capable of activating in the event of a battery fault or if the batteries are not fitted in the latter case to avoid battery fault indications the facility should be disabled see section under Programming The Smoke Screen is supplied with a set of batteries but they are not fitted on delivery Replacement batteries may be obtained from your Smoke Screen instal...

Page 11: ...er the Section LCD LED and Sound indications Setting Smoke Time In the Setting Smoke Time display press to show the current smoke time set Use the and buttons to move up and down to select a time between 5 and 360 seconds in 5 second intervals Press to save the new setting and return to the higher level menu Press to return to the higher level menu without saving changes The delivery Smoke Time Se...

Page 12: ... the LCD and the LED indicator will flash yellow once every 5 seconds a tamper indication will not on its own prevent the Smoke Screen from producing smoke When the Smoke Screen reaches the correct working temperature and a full Smoke Fluid Bag has been correctly installed the LED Indicator will go Green and the LCD Display will show the date and time Stopping smoke If the Hold Off is closed durin...

Page 13: ... n c to open Smoke Screen not heating at the correct rate within 30 min of power on Empty Fluid flash once every 5 sec 1 long beep every 3 min Liquid output n c to open Status output n c to open Fluid less than 10ml or no Bladder installed Low Fluid flash once every 5 sec 1 short beep every 5 min Liquid output n c to open Fluid less than 50 Battery Fault flash once every 5 sec 3 short beep every 5...

Page 14: ...nished by an engineer certified by the manufacturer If you are unsure ask the engineer for his certification ID card It is recommended that the Smoke Screen is checked and the fluid changed annually by the installer or Concept Smoke Screen Always ensure that the Smoke Screen has sufficient fluid or it will not produce smoke when needed It is recommended that the installer or Concept Smoke Screen a...