1.5 TYPICAL INSTALLATIONS
Recommended installation configuration:
Smoke Screen is wall or ceiling mounted in the appropriate location.
Optional Smoke Screen Interface (SSI) usually fitted adjacent to alarm panel.
A Set command supplied by an alarm control panel, or equivalent, in the form of a Normally Closed (N/C)
clean contact relay changing ‘Energised Open’ when the alarm system is set for operation.
An Alarm command supplied by the alarm control panel, or equivalent, in the form of a Normally Closed (N/C)
clean contact relay changing ‘Energised Open’ when the alarm system detects an intruder. This can be a First
Intruder or Confirmed as required.
Optional - A Hold-off PIR (or similar device) located within the same area as the Smoke Screen providing a
confirmation signal to the Smoke Screen to start, or restart, ‘smoke’ production.
Optional - A Panic command in the form of a Normally Closed (N/C) relay or equivalent clean contact such as a
dedicated panic button, that is opened when an instant activation is required.
Optional – Ethernet connection for S monitoring if fitted and required. Specifically for remote monitoring
an Outbound TCP connection on port 8883 is required.