SENTINEL S70 / S100 / S150 

 v7 v1.2 

 

INSTALLATION AND OPERATION 

 

MANUAL 

 

Revised Version:  July 2022

 

Summary of Contents for Sentinel S100

Page 1: ...SENTINEL S70 S100 S150 v7 v1 2 INSTALLATION AND OPERATION MANUAL Revised Version July 2022 ...

Page 2: ...s worth of property defeating criminals and securing premises on an almost daily basis We produce them because we believe you have a right to feel safe and secure Please take the time to read and understand this guide to ensure you achieve the maximum performance from your Smoke Screen If you have any questions that remain unanswered please call our experts at Concept Smoke Screen and we will help...

Page 3: ...0 11 4 Sentinel 4 1 Sentinel module installation testing and registration 12 5 Connections 5 1 5 2 5 3 Circuit board layout Connection Diagram Using Smoke Screen Interface Connection Diagram Generic Alarm 13 14 15 6 Settings 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 6 10 6 11 Screen sensor Energy saving mode Verification timer Service mode Inverting triggers Tamper Reboot Fluid management Battery manage...

Page 4: ... 8 Servicing 8 1 8 2 8 3 8 4 8 5 Live Status LCD LED and sound indications Thermal cut out TCO reset Action after every activation Servicing and fluid replenishment 26 27 28 29 29 9 Miscellaneous 9 1 9 2 9 3 9 4 Glossary FAQ End of product life policy Warranty terms and conditions 30 31 31 32 ...

Page 5: ...n may be used for safety notices in this manual or on the Smoke Screen This type of warning note is used to indicate possible electrical shock hazards that may cause serious injuries or death This type of warning note is used to indicate the possibility of injury caused by hazards other than electrical shock 1 2 HOW DOES YOUR SMOKE SCREEN WORK Your Smoke Screen passes a non toxic fluid through an ...

Page 6: ... installation 1 x Warning sign and documentation You will also need Mains power supply an unswitched 13 amp fused spur connected to a dedicated breaker Connections into the alarm panel or other triggering system PIR or equivalent to provide the hold off where required Ethernet connection if a Sentinel is being used 1 4 OVERVIEW The Smoke Screen is designed to form part of an existing intruder alar...

Page 7: ...ormally Closed N C clean contact relay changing Energised Open when the alarm system detects an intruder This can be a First Intruder or Confirmed as required Optional A Hold off PIR or similar device located within the same area as the Smoke Screen providing a confirmation signal to the Smoke Screen to start or restart smoke production Optional A Panic command in the form of a Normally Closed N C...

Page 8: ...s above the floor facing the area to be protected and using the 30 degree angle nozzle The maximum recommended mounting height above floor level is 3 metres for an S70 4 metres for S100 and S150 the minimum is 1 metre and there should be no obstacle within 1 metre of the smoke output nozzle Also leave a minimum of 150mm clearance to the ceiling Ceiling mounting The optimum ceiling mounting positio...

Page 9: ...s and monitored signals SSI in Ready position if fitted 2 3 ACCESS To access the PCB connections programming panel mounting holes batteries and fluid remove the front cover by unscrewing the set screws on either side and unhooking it from the back plate refitting is the reverse process Installation cable entry is through the serrated grommet on the left side of the back plate 2 4 MOUNTING The Smok...

Page 10: ...he threaded bar will take the weight of the Smoke Screen Any hole made in the ceiling below can be made good with a cosmetic hole surround Note Final machine position should allow an air gap 50mm above ceiling tile or when ducting 2 5 NOZZLE CHANGING To change the nozzle first remove the front cover then remove and replace the nozzle using a 10mm ring spanner sealing it with PTFE tape and ensuring...

Page 11: ...IR both devices must be open to produce smoke NB If no hold off is fitted the terminals should be left without anything connected and will show HO on the display as in an active condition If a Panic output from the alarm system is required to trigger the Smoke Screen we recommend using a DPDT relay connected to break the Set and Alarm Inputs to the SSI This allows isolation of the Smoke Screen whe...

Page 12: ... of 30 seconds are set The Smoke Screen will not respond to the Hold Off input for 30 seconds after it receives a Set and Alarm input it will then delay a further 5 seconds from receiving a Hold Off input before making smoke Re triggering option If a Smoke Delay time has been set the menu gives the option to select the following options for subsequent re triggers initiated by a hold off if the Set...

Page 13: ...s set to 0 0 0 0 This will use DHCP to attempt register onto the network if successful the assigned IP address for the unit will be visible under the Telemetry setting of LCD display menu If a static IP is required you must manually enter IP address and subnet mask You may also need to configure a default gateway address and a DNS server address If you are unsure what settings to use then contact ...

Page 14: ...13 Connections 5 5 1 CIRCUIT BOARD LAYOUT ...

Page 15: ...14 5 2 CONNECTION DIAGRAM USING SMOKE SCREEN INTERFACE Recommended ...

Page 16: ...15 5 3 CONNECTION DIAGRAM GENERIC ...

Page 17: ...the Smoke Screen is in ESM mode and is activated as soon as the alarm is set i e before it has heated to normal operating temperature it will still produce smoke but the length of time of the initial burst of fog will be shortened Extreme When Extreme is selected and the alarm panel input to the Smoke Screen is Unset the Smoke Screen heater is not operated and its temperature reduces to ambient Wh...

Page 18: ...the Set Alarm and Hold off triggers set to n c i e open activate The Panic trigger is set to n o to avoid an inadvertent activation if the facility is not used and the Panic input is left open 6 6 TAMPER There are internal tamper circuits on all the Smoke Screen covers and an external tamper input on PCB terminal block B A Tamper Status output is provided on PCB terminal block F To prevent unwante...

Page 19: ...ce the heater block and connected parts will be extremely hot and will cause injury if touched Switch off and allow the heater block to cool Changing a fluid consumable Obtain a replacement fluid reservoir from your Smoke Screen supplier Open the right hand access panel Lift the reservoir out of the compartment by removing the upper end first Disconnect the fluid monitoring cable Disconnect the fl...

Page 20: ... NOT PRODUCE FOG IF THE CONSUMABLE IS NOT CORRECTLY FITTED INSERT FLUID CONSUMABLE WITH CARE THE QUICKFIT CONNECTOR CAN BE ACCIDENTALY DETATCHED OR FLUID LINE KINKED RESULTING IN REDUCED PERFORMANCE A SHORT TEST FIRE SHOULD BE PERFORMED AFTER A NEW FLUID CONSUMABLE IS FITTED External reservoir A 5000ml external reservoir can be used with Smoke Screen please contact Concept Smoke Screen if you wish...

Page 21: ...ours after a mains power failure at which time the unit is too cold to activate the Smoke Screen will start up normally as soon as mains power is re applied Battery switch The Smoke Screen has a switch on the PCB to permit the batteries to be disconnected from the system whilst remaining in place see the picture above The delivery setting is Off select to On if intending to use the battery facilit...

Page 22: ...f Function Escape will return the LCD to the Live Status display Viewing and setting the functions and variable parameters In the Smoke Screen Status or Current Time display Press Function Escape to access the programmable functions Press Up or Down buttons to scroll through the available functions Press Enter Back to view the current function setting Press Up or Down buttons to scroll through the...

Page 23: ...tch is Off on delivery See Section 6 9 6 Enable Disable ESM Disable Disable ESM Extreme Energy Saving Mode See Section 6 2 7 Smoke Delay 0 seconds 0 to 60 seconds in 1 second intervals See Section 3 1 Re triggering Delay Delay Instant Available if Smoke Delay set to 0 seconds Select Delay to apply set Smoke Delay time to every re trigger by the Hold off Instant no delay See Section 3 1 8 Settle Ti...

Page 24: ... 6 11 SENTINEL REGISTRATION AND REMOTE CONFIGURATION Registration Follow the registration link found on the Sentinel Self Test Page i e http 192 168 16 84 Once registration is complete you will be sent a 4 digit passcode Local Device Status Monitoring Only Navigate to admin page e g http 192 168 16 84 admin Log in using username guest password Leave blank Local Device Status Monitoring and Configu...

Page 25: ...ble a full alarm test should be conducted to check all inputs outputs and wiring connections to the Smoke Screen are correct The Smoke Screen will fire for the designated Smoke Time once the Alarm Set Trigger and Hold off if fitted contacts are open It will re trigger if the Alarm Set remains open and either the Trigger and or the Hold off inputs are cycled after the set Smoke Time It will stop pr...

Page 26: ... on to Smoke Screen Sentience to claim registered Sentinel device https sentience smoke screen com Follow online instructions for monitoring Area under construction at time of writing Further information examples will follow when available ...

Page 27: ...smoke L Low Fluid The Swift Fit fluid level is less than 50 TI Tamper Internal The Tamper Output is giving a tamper alarm Bottom Line Inputs Indication Meaning Explanation S Set The Set input is in an active state A Alarm The Alarm input is in an active state Ho Hold off The Hold off input is in an active state PA Panic The Panic input is in an active state Sm Service Mode The Service Mode Dip swi...

Page 28: ...27 8 2 LCD LED AND SOUND INDICATIONS The Smoke Screen provides on board status monitoring via an LCD a multicolour LED and a sounder Indications displayed are ...

Page 29: ...lowing procedure Make sure mains and battery power to the machine is turned off before resetting the TCO Reset the TCO by pressing on the little button on the top area that is accessed through the hole in protective cover see photo below If the thermal device has tripped it should be possible to hear a click when it resets Switch on the mains power after resetting then turn on batteries Check the ...

Page 30: ...competent by the manufacturer If you are unsure ask the engineer for their certification ID card Smoke Screen servicing To ensure the Smoke Screen remains fully operational it must be regularly serviced by a Concept Smoke Screen certified engineer Failure to service the Smoke Screen may invalidate the warranty Service intervals The Smoke Screen should be serviced annually by a Concept Smoke Screen...

Page 31: ...ervice Mode Smoke Screen is isolated for repair installation Sentinel Sentinel Smoke Screen with IP capability Settle Timer Time after the Smoke Screen is Set during which it will not react to a Hold off input Use for PIR settling time on exit Smoke Fog The Smoke Screen makes a fog rather than produces smoke Smoke Delay Time after an activation demand before the Smoke Screen activates Smoke Mode S...

Page 32: ...ronmental impact of the products we sell To comply with the WEEE Regulations 2013 we label all relevant products with the crossed out wheelie bin symbol and are members of the Comply Direct WEEE compliance scheme Comply Direct have registered us with the Environment Agency as a Producer and will arrange to have any of our equipment collected and recycled as necessary Comply Direct can be contacted...

Page 33: ...k ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any software Defects caused by modifications carried out without CSS s approval Costs incurred by CSS in making any adaptations or modifications of a product necessary for country specific technical or safety standards or specifications or any other costs to adjust the product as a result of any specificat...

Page 34: ...urned to CSS within 21 days of receipt of said replacement part Other information When returning the product for warranty service please pack it very carefully and enclose the instructions for repair CSS shall not be liable for any incidental or consequential damages for breach of any express or implied warranty of this product These warranty terms and conditions are offered to you by CSS without ...

Page 35: ...34 Installer Notes ...

Page 36: ...SENTINEL S70 S100 S150 v7 v1 2 July 2022 1C North End Business Park Station Rd Swineshead Lincolnshire PE20 3PW United Kingdom Tel 44 0 1205 821111 info smoke screen co uk www smoke screen com ...