improper installation can result in injury. 

Be sure to complete all rigging and installation procedures before connecting the main 

power cord to the appropriate wall outlet. 

 

Clamp Mounting: The Pixel Bar Light provides a unique mounting bracket assembly 

that  integrates  the  bottom  of  the  base  and  the  safety  cable  rigging  point  in  one  unit. 

For  additional  safety  be  sure  to  attach  at  least  one  properly  rated  safety  cable  to  the 

fixture using one of the safety cable rigging point integrated in the base assembly. 

 

Regardless of the rigging option you choose for your Pixel Bar Light, always be sure 

to only use the designated rigging point for the safety cable and never secure a safety 

cable to a carrying handle. 

 

DMX-512 control connections 

Connect  the provided XLR cable to  the female  3-pin  XLR output of  your controller 

and  the  other  side  to  the  male  3-pin  XLR  input  the  Pixel  Bar  Light.  You  can  chain 

multiple  bar  lights  together  through  serial  linking.  The  cable  needed  should  be  two 

core  screened  cable  with  XLR  input  and  output  connectors.  Please  refer  to  the 

diagram below. 

 

 

DMX-512 connection with DMX terminator. 

For installation where the DMX cable has to run a long distance or is in an electrically 

noisy  environment,  such  as  in  a  discotheque,  it  is  recommended  to  use  a  DMX 

terminator.  This  helps  in  preventing  corruption  of  the  digital  control  signal  by 

electrical  noise.  The  DMX  terminator  is  simply  an  XLR  plug  with  a  120Ω  resistor 

connected between pins 2 and 3, which is then plugged into the output XLR socket of 

Summary of Contents for V-PIX Vision Bar

Page 1: ...V PIX Vision Bar LED Pixel Bar Light User Manual KEEP THIS MANUAL FOR FURTURE NEEDS...

Page 2: ...ndard DMX512 protocol It is available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theatre studio nightclubs and discos Th...

Page 3: ...tely necessary for the user to follow the safety instructions and warning notes written in this user manual If the device has been exposed to temperature changes due to environmental changes do not sw...

Page 4: ...ling If the external flexible cable or cord of bar is damaged it should be replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard 4 Operation Instru...

Page 5: ...personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the devices weight Fixture installation must always be secured with...

Page 6: ...d never secure a safety cable to a carrying handle DMX 512 control connections Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR...

Page 7: ...se the desire function and Press ENTER to confirm Press MENU to return back last menu No MENU Value Function 1 Addr 1 512 DMX Address Set 2 Chnd 6ch 8ch 12ch 60ch DMX Channel select 3 SLnd Mast SL 1 S...

Page 8: ...0 100 4 0 255 Warm White Dimmer 0 100 5 Color Chase 000 007 No function 008 12 Color chase 1 13 16 Color chase 2 17 20 Color chase 3 Sp 1 9 Auto Running Speed select 1 9 6 Colo Co 1 15 Color choose 7...

Page 9: ...255 Dimmer 0 100 2 0 255 Strobe 3 0 255 Red Dimmer 0 100 4 0 255 Green Dimmer 0 100 5 0 255 Blue Dimmer 0 100 6 0 255 Warm White Dimmer 0 100 7 Color Chase 000 007 No function 008 12 Color chase 1 13...

Page 10: ...mer 0 100 6 0 255 Part 1 Warm White Dimmer 0 100 7 0 255 Part 2 Red Dimmer 0 100 8 0 255 Part 2 Green Dimmer 0 100 9 0 255 Part 2 Blue Dimmer 0 100 10 0 255 Part 2 Warm White Dimmer 0 100 11 Color Cha...

Page 11: ...5 Group 1 Blue Dimmer 0 100 6 0 255 Warm White 1 Dimmer 0 100 55 0 255 Group 14 Red Dimmer 0 100 56 0 255 Group 14 Green Dimmer 0 100 57 0 255 Group 14 Blue Dimmer 0 100 58 0 255 Warm White 14 Dimmer...

Page 12: ...rs cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on con...

Page 13: ...any traces of wear and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot...

Page 14: ...e Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation Instructions Should you need any...

Reviews: