7.10 Alarms
GENERAL
To reset an alarm/warning press the “STOP” or “MENU” buttons.
When an error occurs using the TrueFeed, the display will indicate an error code and description.
Together with the displayed error an output contact will be switched.
The controller itself gives a beeping signal and the alarm LED will illuminate.
To distinguish a Warning or Alarm:
Warning
:
Warning output is ON, but the feeding unit continues running
(24VDC contact, pin 22-23 of the main board will be active,
for example to activate the alarm strobe)
Alarm
:
Alarm output is ON and the
feeding unit stops running
(Potential free contact, pins 26-27 of the main board will be active, for example to
stop the injection molding machine)
Free programmable errors can be configured to an
Alarm
or
Warning
.
For setting the free programmable outputs to an alarm or warning, enter the ALARMS menu.
First the alarm history will be shown. The alarms and warnings will be stored here.
When you press the “MENU” button again you will enter the alarm configuration menu.
Here you can set the alarm or warning output with and press “ENTER”.
ALARM HISTORY
All alarms and warnings will be stored in the alarm history.
Go to the ALARMS <menu>
Press to scroll to the stored alarms (max. 50).
The alarm history can be reset by the supervisor in CONFIGURATION <menu> by
Master reset: Alarm
Listed below are the following Errors:
Error
Code
Warnings
00
Low hopper level
Material is below the hopper empty weight
01
Maximum deviation exceeded
The deviation of the material output is too high
02
Filling system unable to load material
Fill system is not working correctly
03
Maximum RPM exceeded, change
dispensing cylinder for higher capacity
Calculated motor speed is too high
05
Calibration, no weight change
No weight change while calibrating
07
Minimum motor speed < 0.1 RPM
Calculated motor speed is too low
Alarms
08
Motor connection failure
Motor not connected/Motor or connection damaged
09
Parameters damaged
Check configuration parameters
10
Parameters set to factory defaults
Check all parameter settings
11
Loadcell calibration set to factory defaults
Recalibrate the loadcell
13
Loadcell connection failure
Loadcell connection is not correct
14
UDP link error
No Ethernet connection between the Regrind and Color units
15
Software version mismatch
Software versions of the Regrind and Color units are different
31 Dual Feed TrueFeed Manual
Summary of Contents for TrueFeed
Page 4: ......
Page 41: ...APPENDIX A TrueFeed Print view INSIDE VIEW OF THE CABINET 37 Dual Feed TrueFeed Manual...
Page 42: ...APPENDIX B TrueFeed Wiring diagram 38 Dual Feed TrueFeed Manual Only with Dual TrueFeed...
Page 44: ...APPENDIX D TrueFeed General Dimensions 40 Dual Feed TrueFeed Manual...