XTD-1250KL,12.75-14.5 GHZ,L01,EN1
Document No. 305-0521-997
REV 4
Page 4 of 13
3.1.14
Prime Power
180-260
VAC
2800
VA max
0.95
Power factor min
47 to 63
Hertz
Single Phase
3.1.17
Serial Interface
3.1.17.1
RS-232
Monitor and Control
3.1.17.2
RS-422/485 (4-Wire Mode or
Monitor and Control
2-Wire Mode)
3.1.16
Controls
This specification describes the control functions of the HPA. A limited number of control functions can be
applied locally from the front panel of the HPA as well as remotely via the serial interface. Some of the control
functions can only be applied via the local controls on the HPA. The following paragraphs specify these control
functions and the REMOTE capability. Details of the communication protocol for serial control and the menu
system for the local control are detail in the operation and installation manual for this product. Please refer to
that document for detailed information.
3.1.16.1
Controls, Local
3.1.16.1.1
AC Prime Power (ON/OFF)
3.1.16.1.2
Local/Remote
3.1.16.1.3
HV (ON/OFF)
3.1.16.1.4
RF Inhibit (Standard Configuration)*
* The RF output will inhibit (turn OFF) by turning OFF the Preamplifier when M&C connector
Pin (g) is connected to Pin (f) and Pin (Y) is grounded to Pin (Z).
3.1.16.2 Controls, Remote
3.1.16.2.1
HV (ON/OFF)
3.1.16.2.2
Heater Standby (ON/OFF)
3.1.16.2.3
Gain
3.1.16.2.4
Minimum Power Alarm/Fault
3.1.16.2.5
Maximum Power Alarm/Fault
3.1.16.2.6
Power Measurement Units (Watts, dBm, dBw)
3.1.16.2.7
Fault Reset
3.1.16.2.8
COM 1 configuration (baud rate, parity, start/stop bits)
3.1.16.2.9
COM 2 configuration (baud rate, parity, start/stop bits)
3.1.16.2.10
HPA Address
Note: Heater Standby reduces the TWT’s heater voltage for situations where the high voltage is
off. Using this mode significantly increases the life of the TWT where high voltage is off
for extended periods of time.