MNC-0500-026
32 of 32
Revision M
Amplifier Communication and Protocol, Rabbit CPU
Waveguide Switch Control
Command Byte:
‘U’
Format:
‘U3’ Activate override mode and switch in Amplifier Switch 2.
‘U2’ Activate override mode and switch in other Amplifier Switch 2.
‘U1’ Activate override mode and switch in Amplifier Switch 1.
‘U0’ Activate override mode and switch in other Amplifier Switch 1.
‘UM’ Activate override mode.
‘UA’ Terminate override mode, activating automatic mode.
Notes:
When sending a ‘U3’, ‘U2’, ‘U1’ or ‘U0’ command, also send
a ‘UM’ command to the other amplifier to prevent unwanted automatic-mode
switches.
Compatibility:
For Redundant ODUs only
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.