Operation  

 

RCU101 1:1 Protection Switch

 

Page 3-2  

 

TM055 - Rev. 2.2 

 

 

Primary Backup Action 

 

    0 

 

     0 

 

No action.  Whoever was online, stays online. 

 

    1 

 

     0 

 

Backup converter is placed online. 

 

    0 

 

     1 

 

Primary converter is placed online. 

 

    1 

 

     1 

 

No action.  Whoever was online, stays online. 

 

In addition to providing the switching logic, the RCU101 provides each converter with 4 ID bits that tell 
the particular converter whether it is the primary or backup converter.  The ID bits are as follows: 

ID Bits  

Meaning 

 1010 

 Backup 

 1011 

 Primary 

 

3.2   

Manual/Auto Mode Selection Switch 

The Manual/Auto mode selection switch is located on the front of the RCU101 and is used in the 
following manner: 

When the switch is placed to the far left (PRI), the primary converter is placed online and will stay 
online even if it faults. 

When the switch is placed to the far right (BU), the backup converter is placed online and will stay 
online even if it faults. 

When the switch is placed in the middle position, it will automatically switch to the backup when a 
fault is detected in the online converter. 

If the front panel switch is accidentally left in the manual mode, the RCU101 can be placed in the auto 
mode remotely by sending a Manual Command followed by an Auto Command to the converter that 
was deselected by the front panel switch.  (See the applicable converter manual for more details). 

3.3 Switch 

LEDs 

The are two sets of identical switch LEDs, one set for the primary converter and one for the backup 
converter.  Their meanings are the same. 

Online LED -    

The Online LED indicates that the corresponding converter has been placed 

online by  

  the switch. 

Standby LED - The Standby LED indicates that the corresponding converter is in Standby. 

Fault LED -  

The Fault LED indicates that the corresponding converter is currently faulted. 

Manual LED -   The MANUAL LED indicates that the converter has been manually selected and will 
  

stay 

there. 

3.4 

Troubleshooting and/or Replacing a Faulted Converter 

Prior to testing or replacing a faulted converter it is strongly recommended that the mode selection 
switch be set to manually select the converter that is currently online.  Once the faults on the faulted 
converter have been cleared (or the converter has been replaced), the converter can be placed in the 
standby by moving the mode selection switch back to the center, thus placing the switch in auto 
mode. 

Note:  If the switch is left in the middle (auto) position while tests are being performed on a converter 
that is not faulted, and the online converter faults, the switch will automatically toggle control and data 

Summary of Contents for Radyne RCU101

Page 1: ...ontained in this document supersedes all previously published information regarding this product This manual is subject to change without prior notice RCU101 1 1 Converter Protection Switch Installati...

Page 2: ...Copyright 2002 Comtech EF Data All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161...

Page 3: ...nd for the stated period following the date of shipment Upon beginning of the applicable Radyne ComStream warranty period all customer s remedies shall be governed by the terms stated or referenced in...

Page 4: ...UNIT OR PRODUCT OR SERVICE FURNISHED OR TO BE FURNISHED AS THE CASE MAY BE WHICH IS THE SUBJECT OF CLAIM OR DISPUTE Statements made by any person including representatives of Radyne ComStream which a...

Page 5: ...lar purpose No responsibility for any errors or omissions that may pertain to the material herein is assumed Radyne ComStream Corporation makes no commitment to update nor to keep current the informat...

Page 6: ...h Fault Status Connector 2 5 2 4 3 RCU101 RF and IF Rear Panel Connectors 2 5 2 4 4 Interfaces Common to the Converters 2 6 2 4 5 Operator Serial I O 2 6 2 4 6 Up Downconverter Equipment RS485 Port 2...

Page 7: ...TM054 Rev 2 2 vi...

Page 8: ...tching of both the RF and IF signal paths Converter fault and circuit restoration is initiated from the summary fault contacts of the online converter Upon clearing of the fault in the online converte...

Page 9: ...Description SFC4200 C Band Downconverter Page 1 2 TM054 Rev 2 2...

Page 10: ...with the following items for proper installation 1 RCU101 1 1 Protection Switch 2 One cable set per paragraph 2 3 3 Installation and Operation Manual 2 1 1 Removal and Assembly If using a knife or cut...

Page 11: ...Installation RCU101 1 1 Protection Switch Page 2 2 TM055 Rev 2 2...

Page 12: ...RCU101 1 1 Protection Switch Installation TM055 Rev 2 2 Page 2 3...

Page 13: ...2 The protection switch interface connector is a DB 15 pin connector that connects each converter with the backup switch unit This cable is not daisy chained between converters but serves as a direct...

Page 14: ...ult Relay N O 10 Switch Online Status Com B active A inactive 11 Switch Online Status N C Primary Online continuity 12 Switch Online Status N O Backup Online continuity 13 Remote Primary Active Low 14...

Page 15: ...ode 2 4 3 6 J8 IF Prime This BNC F connector goes to the IF connector of the primary converter This connection is made via the supplied IF cable assembly with the RCU101 2 4 3 7 J9 IF In Out This BNC...

Page 16: ...of jumper selections is as follows Configuration JP4 1 JP4 2 JP4 3 JP4 4 JP4 5 JP4 6 JP3 JP5 JP6 JP7 JP8 RS232 OUT OUT OUT OUT IN IN OUT OUT IN OUT OUT RS422 IN IN IN IN OUT OUT OUT OUT OUT OUT IN RS...

Page 17: ...Data and Receive Data is accomplished in the inter converter cable as the hardware interface is identical for all converters J6 DB 9 Pin Description 10 Pin AS 3048 1 GND 1 2 SRCLK 3 3 No Connect 5 4...

Page 18: ...ed Refer to the converter manual for more details MENU for next menu ENTER for Learn Mode ENTER Automatic Learning in Process Automatic Learning Failed Automatic Learning MENU Successfully Completed R...

Page 19: ...a Manual Command followed by an Auto Command to the converter that was deselected by the front panel switch See the applicable converter manual for more details 3 3 Switch LEDs The are two sets of id...

Page 20: ...otection Switch Operation TM055 Rev 2 2 Page 3 3 to the converter under test This can result in unwanted operation when the converter under test is not at the same frequency or gain levels as the onli...

Page 21: ...Operation RCU101 1 1 Protection Switch Page 3 4 TM055 Rev 2 2...

Page 22: ...RCU101 1 1 Protection Switch Operation TM055 Rev 2 2 Page 3 5...

Page 23: ...ll four LEDs of the graphical transfer switch display on the front panel illuminate In this case the RCU101 logic has commanded the transfer switch to a certain position This will illuminate the new p...

Page 24: ...Maintenance RCU101 1 1 Protection Switch 4 2 TM055 Rev 2 2...

Page 25: ...TM055 Rev 2 2 Page 5 1...

Page 26: ...5 F QTY 1 Summary Status DB15 F QTY 1 Switch RF Specifications Switched RF Ports Bandwidth DC 18 GHz Insertion Loss 0 4 dB C band 0 5 dB Ku band Impedance 50 Ohms VSWR 1 5 1 Max Isolation 70 dB min C...

Page 27: ...RCU101 1 1 Protection Switch Serial Protocol TM055 Rev 2 2 A 2...

Page 28: ...TM055 Rev 2 2 B 1 Appendix B RCU101 Block Diagram Configuration Drawings and Schematics...

Page 29: ...TM055 Rev 2 2 B 2 Figure B 1 Functional Block Diagram...

Page 30: ...TM055 Rev 2 2 B 3 Figure B 2 Top Level Assembly...

Page 31: ...TM055 Rev 2 2 B 4 Figure B 3 AS 3265 Front Panel Assembly...

Page 32: ...TM055 Rev 2 2 B 5 Figure B 4 AS 3527 Switch Assembly...

Page 33: ...TM055 Rev 2 2 B 6 Figure B 5 AS 3527 Switch Assembly...

Page 34: ...TM055 Rev 2 2 B 7 Figure B 6 CA 4014 Cable Assembly...

Reviews: