MBT-4000B Multi-band Transceiver System
Revision 1
Serial-based Remote Product Management
MN/MBT4000B.IOM
6–4
6.2.4.1 Start of Packet
Because this is used to provide a reliable indication of the start of packet, these two characters may not appear anywhere else within the
body of the message:
Controller-to-Target:
This is ‘less-than’ the character '
<
' (ASCII code 60).
Target-to-Controller:
This is the ‘greater-than’ character '
>
' (ASCII code 62).
6.2.4.2 Target Address
Up to 9,999 devices can be uniquely addressed. In both EIA-232 and EIA-485 applications, the permissible range of values is 1 to 9999.
The BUC sub-device may also be addressed by appending the corresponding sub-device address. The sub-device address for the BUC is
‘A1’. For example, a mute command addressed to the BUC attached to an MBT-4000B at address 0412 will be:
<0412A1/MUT=1{CR}
The format of the response will be:
>0412A1/MUT={CR}{LF}
The Controller sends a packet with the address of a Target – the destination of the packet. When the Target responds, the
address used is the same address, to indicate to the Controller the source of the packet. The Controller does not have its own
address.
6.2.4.3 Address Delimiter
This is the ‘forward slash’ character '
/
' (ASCII code 47).
6.2.4.4 Instruction Code
This is a three-character alphabetic sequence that identifies the subject of the message. Wherever possible, the instruction codes have
been chosen to have some significance.
For Example:
MUT
for
MUT
e. This aids in the readability of the message, should it be displayed in its raw ASCII form.
Summary of Contents for MBT-4000B
Page 14: ...MBT 4000B Multi Band Transceiver System Revision 1 Preface MN MBT4000B IOM xiv Notes...
Page 20: ...MBT 4000 Multi Band Transceiver System Revision 1 Introduction MN MBT4000B IOM 1 6 Notes...
Page 84: ...MBT 4000B Multi Band Transceiver System Revision 1 Appendix B MN MBT4000B IOM B 8 Notes...
Page 85: ......
Page 86: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...