MBT-4000B Multi-Band Transceiver System
Revision 1
External Connectors
MN/MBT4000B.IOM
3–5
3.2.1.4 J3 | UNIT 1 COMM
Use the
J3 | UNIT 1 COMM
connector to connect the MBT-4000B Base Module
Unit 1 section to the BUC-4000 Block Up Converter Module
J6 | COMM
connector via the 15-15 Power & Signal Harness (CEFD P/N CA/WR10963-1),
shown in
Figure 3-3
.
Table 3-4. J3 | UNIT 1 COMM Connector Pinouts
Figure 3-3. J6 | COMM (BUC Module) to J3 | Unit 1 COMM (Base Module) Connection
Pin
Signal
A
SUM FLT
M
RxD BXC
C
Tx+ BXC
D
GND
E
+7.5V
F
+7.5V
G
+15V
H
GND
J
Rx+ BXC
K
Rx- BXC
L
Tx- BXC
B
TxD BXC
N
SPARE
P
10 MHz REF
R
SPARE
NOTE – Mating Connector:
CEFD P/N CN/8LT5-15B15PN
( Souriau 8LT5-15B15PN / Amphenol MS27467T15B15P)