FOB-21 Installation guide
Page 4
COMTECH ltd.
Clear about 30 cm in length cable
isolation and carefully wipe off excess gel.
When incoming cable is fixed, using
openings between units pull sectors till
necessary unit, fasten it and pull sectors
to panel's surface.
6
7
8
Cleared fiber must be placed inside the
cassette in three circles.
9
Insert adapters in front panel.
10
Insert connector pigtails into adapter.
Pigtails should be previously cut 35-37
cm in length.
11
Pigtail ends should be lead onto panel's
surface through designed openings.