DT4572 X-Band Down Converter
Rev. 0
Remote Control
MM/DT4572.IOM
62
B.6.4.2 M
AINTENANCE
S
TATUS
Command
Details
Maintenance Status:
<DEV/RMS_'cr'
Confirmation: >DEV/RMS_'cr'
P15_xx.x'cr'
15 VDC Supply
P14_xx.x'cr'
14 VDC Supply
VCC_x.x'cr'
VCC
Supply
5VD_x.x'cr'
Display 5 VDC
TEM_xx'cr'
Temperature
IFL_xx.x'cr'
IFLO
Tuning
SUM_xx.x'cr'
Sum Loop Tuning
COR_xx.x'cr'
Coarse Loop Tune
FIN_xx.x'cr''lf'] Fine Loop Tuning.
B.6.4.3 U
TILITY
S
TATUS
Command
Details
Utility Status:
<DEV/RUS
_
'cr'
Confirmation: >DEV/RUS_'cr'
COMM_aaaaaa'cr'
EIA-232C
or
EIA-485
ADD_xxx'cr'
Address (001 to 255)
BR_nnnn'cr'
Baud Rate (1200, 2400, 4800, 9600,
19K2,
or
38K4)
FMT_x-y-z’cr’
Data Format x=data, y=parity, z=stop
bit
(8-N-1,
7-E-2,
7-O-2)
REF_xxx'cr'
Osc. Adjust (000 to 255)
SLP_x.x'cr'
Slope Adjust (0.0 to 1.0)
CON_xx'cr'
LCD Contrast (0 to 30)
LCD_xx'cr''lf']
LCD Brightness (0 to 30).
B.6.4.4 A
LARM
S
TATUS
Command
Details
Alarm Status:
<DEV/RAS_'cr'
Confirmation: >DEV/RAS_'cr'
P15_xx'cr'
15 VDC Fault
P14
_
xx'cr'
14 VDC Fault
VCC_xx'cr'
VCC
Fault
5VD
_
xx'cr' 5VD
Fault
TEM_xx'cr'
Temperature
Fault
IFL_xx'cr'
IFLO Lock Fault
SUM_xx'cr'
Sum Lock Fault
COR
_
xx'cr' Coarse
Lock
Fault
FIN
_
xx'cr'
Fine lock Fault
HSB_xx’cr’
High Speed Bus Fault
*REF
_
xx'cr''lf'] Ref. Lock Fault
xx = OK or FT
Note:
REF_xx is only returned if an external reference is present.
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...