DT4572 X-Band Down Converter
Rev. 0
Redundant System Operation MM/DT4572.IOM
39
A.4 R
EDUNDANT
S
YSTEM
C
ONFIGURATION
A.4.1 I
NITIAL
C
ONFIGURATION
Redundant system configuration is controlled from the converter’s front panel
configuration menu. Each online unit is assigned a redundancy configuration address.
This address is dependent on the location of the online converter with reference to the
backup. The unit closest to the backup must be converter # 1. The next unit down must
be converter # 2. Figure 28 shows the appropriate entries for a 1:3 system
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-BU---1:03--
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-01----POL-1
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-02----POL-1
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-03----POL-1
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
Figure 28. 1:3 Front Panel Displays
Configure the online units first, and then configure the backup unit. Redundant polling
starts when the backup is configured. If this polling starts before the online units are
configured, a high-speed bus fault will result. This fault should clear when configuration
is completed. At this point, control of the redundant system is performed from the backup
Converter.
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...