DT4572 X-Band Down Converter
Rev. 0
System Operation
MM/DT4572.IOM
27
3.3.3.2 C
ONFIGURE
C
ONVERTER
T
O
P
RE
-S
ELECT
This command allows the local operator to pre-select from 1 to 32 frequencies to pre-set
a programmed frequency channel and attenuation setting.
3.3.3.3 C
LEAR
D
ATA
F
ROM
P
RE
-S
ELECT
This command allows the local operator to clear a pre-set frequency and attenuation
setting from a pre-selected converter.
3.3.3.4 P
ROGRAM
P
RE
-S
ELECT
This command allows the local operator to input a pre-set frequency channel and
attenuation settings into a converter.
3.3.4 M
ONITOR
S
TATUS
F
UNCTION
M
ENU
Monitors and displays the status of:
15 and 14 VDC power supplies.
Converter internal temperature.
IFLO tuning voltage level.
Synthesizer Sum., Coarse and Fine Loop tuning.
3.3.5 C
URRENT
F
AULTS
F
UNCTION
M
ENU
Displays the status of the current fault conditions. The LCD display will indicate "FT"
when a fault condition exists. The display will indicate "OK" when a fault has not
occurred.
3.3.5.1 P
OWER
F
AULTS
Displays the DC voltage power supply faults.
15 VDC Power Supply.
14 VDC Power Supply.
VCC voltage.
3.3.5.2 C
ONVERTER
O
SCILLATOR
F
AULTS
Displays the converter oscillator faults:
IFLO Lock Detect.
Reference Oscillator Lock Detect (only present if external reference is detected.).
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...