DMD1050TS Satellite Modem Board
Revision 1
Maintenance and Troubleshooting
5–3
MN-DMD1050TS
5.2.1.4
Minor Rx Alarms
Alarm
Possible Cause
BUFF UNDERFLOW
Shows that a Doppler Buffer underflow has occurred
BUFF NEAR EMPTY
Shows that the Doppler Buffer is about to underflow
BUFF NEAR FULL
Shows that the Doppler Buffer is about to overflow
BUFF OVERFLOW
Shows that a Doppler Buffer overflow has occurred
RX DATA ACTIVITY
Shows that there is no Rx Data activity; for the Ethernet Interface, shows that no Ethernet
port is active (no cable is connected)
SAT AIS
Shows that AIS has been detected in the receive satellite data stream
IFEC LOCK
Shows that the Inner Codec is not locked
TPC Conflict Chk
Shows there is a TPC mismatch
OFEC LOCK
Shows that the Reed-Solomon Decoder is not locked
INTERLEAVER
Shows that the Reed-Solomon Interleaver is not synchronized
EBNO (dB)
Shows that the Eb/No is outside of limits
IBS BER
Shows that there are more than one in 1000 bits in error in IBS mode
RX DVB FRAME
LOCK
Shows that the Rx Satellite Data Stream Framing is not DVB
Encryption
TRANSEC Module is enabled but not synchronized
5.2.1.5
Common Major Alarms
Alarm
Possible Cause
TERR FPGA CFG
Shows an Interface Card FPGA configuration failure, likely caused by a missing or incorrect
file
CODEC FPGA CFG
Shows Turbo Codec Card FPGA configuration failure, likely caused by a missing or incorrect
file
CODEC Dev CFG
Shows Turbo Codec ASIC failed to program
+1.5V RX SUPPLY
Shows the measured voltage of the 1.5 Volt Rx power bus inside the modem
+1.5V TX SUPPLY
Shows the measured voltage of the 1.5 Volt Tx power bus inside the modem
+3.3V SUPPLY
Shows the measured voltage of the +3.3 Volt power bus inside the modem
+5V SUPPLY
Shows the measured voltage of the +5 Volt power bus inside the modem
+12V SUPPLY
Shows the measured voltage of the +12 Volt power bus inside the modem
-12V SUPPLY
Shows the measured voltage of the -12 Volt power bus inside the modem
+20V SUPPLY
Shows the measured voltage of the +20 Volt power bus inside the modem
EXT CLOCK ACT
Shows that the External Clock is not active
EXT REF ACT
Shows no activity on the External Reference
EXT REF LOCK
Shows that the External Reference PLL is not locked
Transec Pwr Test
Shows the TRANSEC module has failed POST (Power-On Self Test)
Summary of Contents for DMD1050TS
Page 18: ...DMD1050TS Satellite Modem Board Revision 1 Table of Contents TOC 16 MN DMD1050TS BLANK PAGE...
Page 24: ...DMD1050TS Satellite Modem Board Revision 1 Preface vi MN DMD1050TS BLANK PAGE...
Page 76: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 44 MN DMD1050TS BLANK PAGE...
Page 86: ...DMD1050TS Satellite Modem Board Revision 1 Rear Panel Interface 4 10 MN DMD1050TS BLANK PAGE...
Page 196: ...DMD1050TS Satellite Modem Board Revision 1 Web Browser 7 74 MN DMD1050TS BLANK PAGE...
Page 234: ...DMD1050TS Satellite Modem Board Revision 1 Appendix A A 2 BLANK PAGE...
Page 246: ...DMD1050TS Satellite Modem Board Revision 1 Appendix C C 10 MN DMD1050TS BLANK PAGE...
Page 256: ...DMD1050TS Satellite Modem Board Revision 1 Appendix D D 10 MN DMD1050TS BLANK PAGE...
Page 268: ...DMD1050TS Satellite Modem Board Revision 1 Appendix F F 10 MN DMD1050TS BLANK PAGE...
Page 272: ...DMD1050TS Satellite Modem Board Revision 1 Appendix G G 4 MN DMD1050TS BLANK PAGE...
Page 278: ...DMD1050TS Satellite Modem Board Revision 1 Appendix H H 6 MN DMD1050TS BLANK PAGE...
Page 298: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 20 MN DMD1050TS BLANK PAGE...
Page 300: ...DMD1050TS Satellite Modem Board Revision 1 Appendix J J 2 MN DMD1050TS BLANK PAGE...
Page 315: ......
Page 316: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...