background image

 

DMD1050TS Satellite Modem Board 

 

Revision 1

 

 

Web Browser 

7–51 

MN-DMD1050TS 

7.7.4.3 

Monitor | Event Page 

 

Figure 7-29. Monitor | Event Page Example 

Monitor | Event Page 
Delete All 

 

Use to delete all events in the buffer. 

Event Type 

 

I - Informational 

 

Y - Yellow alarm 

means a transmit or 

receive warning 

condition 

 

R - Red alarm means a 

transmit or receive 

failure, losing traffic 

Use to sort the Event Buffer by warning level, time, date, or 

event description. Use the log to help examine event 

occurrences. 

Summary of Contents for DMD1050TS

Page 1: ...nd Operation Manual Part No MN DMD1050TS Revision 1 IMPORTANT NOTE The information contained in this document supersedes all previously published information regarding this product Product specificati...

Page 2: ...Arizona 85281 USA 480 333 2200 FAX 480 333 2161 Revision History Rev Date Description 0 Jan 2017 Initial Release 1 May 2018 Chapter 6 Revised tables 6 1 through 6 17 Added Acronym List and Unit of Mea...

Page 3: ...tion Accessibility 1 2 CHAPTER 2 INSTALLATION 2 1 2 1 Unpacking and Inspection 2 1 2 2 Installation Requirements 2 2 2 3 Removal from Container and Assembly 2 2 2 4 Installation Considerations 2 2 2 4...

Page 4: ...23 3 12 2 R S Code Rate 3 23 3 12 3 Interleaving 3 23 3 13 DMD1050TS Automatic Uplink Power Control AUPC Operation 3 25 3 13 1 Radyne AUPC 3 25 3 13 2 EF AUPC 3 26 3 13 3 Near Side AUPC 3 26 3 14 Asy...

Page 5: ...Modulator 6 6 6 3 Demodulator 6 7 6 4 Plesiochronous Buffer 6 8 6 5 Monitor and Control 6 8 6 6 Terrestrial Interfaces 6 8 6 7 Environmental 6 8 6 8 Physical 6 8 6 9 BER Specifications 6 9 6 9 1 BER P...

Page 6: ...5 System Menu 7 64 7 7 6 Test Menu 7 69 7 8 TRANSEC Module HTTP Interface 7 73 CHAPTER 8 TRANSEC MODULE HTTPS INTERFACE 8 1 8 1 TRANSEC Module Overview 8 1 8 2 TRANSEC Module HTTPS Interface 8 1 8 3 O...

Page 7: ...1 Connect the Modem Ethernet Cable to a Network Link C 5 C 4 2 Connect the Modem Ethernet Cable Directly to a Computer without a Network C 5 C 5 Test the Ethernet Connection using the Ping Command Op...

Page 8: ...pe FEC or Application F 9 APPENDIX G STRAP CODES G 1 G 1 Introduction G 1 APPENDIX H SOFTWARE UPGRADE PROCEDURE H 1 H 1 Software Upgrade Procedure H 1 H 2 Terminal Software Upgrade H 1 H 3 Required Eq...

Page 9: ...Performance Viterbi w RS 6 11 Figure 6 4 8PSK BER Performance Trellis 6 12 Figure 6 5 16QAM BER Performance Viterbi 6 13 Figure 6 6 16QAM BER Performance Viterbi w RS 6 14 Figure 6 7 O QPSK BER Perfo...

Page 10: ...e Example 7 69 Figure 7 39 Test I Q Plot Page Example 7 71 Figure 7 40 Test Spectrum Plot Page Example 7 72 Figure 8 1 Tools Internet Options Advanced Security Settings 8 3 Figure 8 2 Configure Page 8...

Page 11: ...4 Initial Setup DMD1050TS Demodulator IF I 5 Figure I 5 Initial Setup DMD1050TS Demodulator Data I 6 Figure I 6 Initial Setup DMD1050TS Demodulator ITA I 6 Figure I 7 Initial Setup DMD1050TS Modulator...

Page 12: ...Turbo 6 26 Table 6 8 BPSK BER Performance Turbo 6 26 Table 6 9 8PSK BER Performance Turbo 6 26 Table 6 10 16QAM BER Performance Turbo 6 26 Table 6 11 B O QPSK BER Performance LDPC 6 27 Table 6 12 8PS...

Page 13: ...TA Setup I 7 Table I 4 Transmit ITA Functions I 8 Table I 5 Receive ITA Functions I 8 Table I 6 ITA Waveform Masks Modulator UUT I 9 Table I 7 ITA Waveform Masks Demodulator UUT I 10 Table I 8 ITA Wav...

Page 14: ...r CBC Code Block Chaining CDMA Code Division Multiple Access CLI Command Line Inerface COMMSPEC Communication Specification CRC Cyclic Redundancy Check DC Direct Current DHCP Dynamic Host Configuratio...

Page 15: ...formation Throughput Adaption IV Initialization Vectors KDF Key Derivation Function LAN Local Area Network LDPC Low Density Parity Check LED Light Emitting Diode M C Monitor and Control MIP Microproce...

Page 16: ...arrier Per Channel SCR Serial Clock Receive SCT Serial Clock Transmission SCTE Serial Clock Transmission External SKL Simple Key Loader SNMP Simple Network Management Protocol SSH Secure Shell ST Send...

Page 17: ...Hz Hertz kHz kiloHertz dB decibel dBc Decibels relative t the carrier dBm Decibel milliwatts F Fahrenheit degrees Kbps Kilobit per second kg kilogram ksps Kilosymbols per second lbs pounds mA Milli a...

Page 18: ...DMD1050TS Satellite Modem Board Revision 1 Table of Contents TOC 16 MN DMD1050TS BLANK PAGE...

Page 19: ...ormational document intended for the persons responsible for the operation and maintenance of the modem Conventions and References Patents and Trademarks See all of Comtech EF Data s CEFD Patents and...

Page 20: ...e unbalanced and balanced voltage digital interface circuits applicable to both long haul and tactical communications Specifically these references apply to the MIL STD 188 114A electrical characteris...

Page 21: ...unit rear panels All other references in the manual refer to EIA designations CAUTION YOU SHOULD CAREFULLY REVIEW THE FOLLOWING INFORMATION Safety and Compliance This product is designed for integrati...

Page 22: ...he repaired or replaced parts Limitations of Warranty The warranty does not apply to any part of a product that has been installed altered repaired or misused in any way that in the opinion of Comtech...

Page 23: ...rporation s products the aforementioned warranty and shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser lessee or user based upon allegations...

Page 24: ...DMD1050TS Satellite Modem Board Revision 1 Preface vi MN DMD1050TS BLANK PAGE...

Page 25: ...165A standards STANAG 4486 Edition 3 EBEM FIPs 140 2 Transmision Security IDR IBS and DVB Data rates up to 37 Mbps Figure 1 1 DMD1050TS Satellite Board Modem Top View The DMD1050TS remote accessibilit...

Page 26: ...ays Features and options installed when the unit is ordered Feature upgrades Hardware options you can install at your location Options installed in a unit at a Comtech EF Data Service Center 1 2 1 Fea...

Page 27: ...spect the modem as follows Step Procedure 1 Cut the tape at the top of the carton indicated by OPEN THIS END 2 Remove the cardboard foam space covering the modem 3 Remove the modem and user s manual f...

Page 28: ...ation limited vibration no exposure to condensation moisture and a stable power source Mating connectors are supplied with each unit A full description of the modems pin outs can be found in Section 4...

Page 29: ...ectromagnetic field EMF generator to prevent output signal corruption and incorrect receive operation Do not install the DMD1050TS in an unprotected outdoor location where there is direct contact with...

Page 30: ...y and Modulator Output Power are set independently of the strap code Modulator Data Rate 2 048 Mbps Mode Closed Network Satellite Framing None Scrambler V 35 IESS Inner FEC 1 2 Rate Viterbi Outer FEC...

Page 31: ...Browser or the Terminal Mode Both have the advantage of giving full screen access to all of the modem s parameters However a separate terminal or computer running a Terminal Program is necessary The m...

Page 32: ...6 3 1 Web Browser and Terminal Interfaces Reset If you cannot use the Web Browser or Terminal interface reset the interface defaults To reset the interface defaults use the shorting plug CNRSHUNT Do t...

Page 33: ...S uses three printed circuit cards in its design The standard configuration consists of L Band Assembly Digital Baseband Assembly FIPs 140 2 TRANSEC Security module This configuration includes built i...

Page 34: ...uit Card and modulated at the desired frequency The L Band modulated signal is then passed through a microprocessor controlled variable attenuator providing gain control of the output signal In the co...

Page 35: ...arious Forward Error Correction FEC options digital voice processing and several different modulation demodulation formats Also included on the Baseband Printed Circuit Card are a MIL 188 114A RS 422...

Page 36: ...a connections to the remote port terminal port Ethernet port and alarm port The M C runs on software programmed into its Flash memory The memory can be reprogrammed via the Ethernet port to allow chan...

Page 37: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 5 MN DMD1050TS Figure 3 4 DMD1050TS FIPS 140 Level 2 TRANSEC Processing Module Block Diagram...

Page 38: ...rocessor In Closed Net mode the data passes through the framer unaltered In IDR IBS framing enabled mode it adds the applicable framing as defined in IESS 308 and 309 The data is then sent to the R S...

Page 39: ...Processor Data received from the satellite passes through the BB Loopback Circuit to the R S decoder to the deframer The deframer acquires the IBS IDR DVB frame synchronizes the R S decoder and extrac...

Page 40: ...local copy of the Traffic Encryption Keys TEK and the Initialization Vectors IV It also provides Built In Self Test BIST functions per the FIPS 140 2 level requirements Finally it provides a simple f...

Page 41: ...RS 485 signal levels This port is intended for use in computer based remote M C All functions of the modem can be monitored and controlled from this port via a common terminal connected to the Termina...

Page 42: ...screen a break signal on the communications line pressing ESC on the terminal or Power On of the modem The Terminal Mode shows the status of all user parameters controlled and read by the processor I...

Page 43: ...cimal addresses on one control bus range from 032 through 255 for a total of up to 224 devices per bus Address 255 of each control bus is usually reserved for the M C computer See MN DMDREMOTEOP the R...

Page 44: ...050 DMD2050E and the OM20 with High level Data Link Control HDLC selection RADYNE SLM 5650A using a Gigabit Bridge card with HDLC Comtech CDM 570 CDM 625 with the HDLC selection Managed 570 It allows...

Page 45: ...of the Ethernet related menus can be used to control the interface 1 Setup the Tx Interface Menu to see Chapter 7 a Set the Terrestrial Interface to Ethernet b Set the Ethernet Flow Control as desired...

Page 46: ...on Port 2 is forwarded to one of the other LAN side ports Port 1 and is not transmitted over the satellite This is useful in a point to multipoint configuration as shown in Figure 3 6 3 7 1 6 Etherne...

Page 47: ...Ethernet interface operate in a FIFO like manner with no reordering of packets This can be established by using a single port on the Ethernet interface and setting the Ethernet QoS Type to Port Based...

Page 48: ...r Count by pressing Enter Link Status These statuses are available in the Monitor Menu Link Status Sub Menu when the Ethernet Data Interface is selected o Port 2 Status shows the current status of LAN...

Page 49: ...restrial Loopback Tx Data port is looped back to the Rx Data port after the interface driver receiver prior to the framing unit Tx Baseband Loopback Tx Data port is looped back to the Rx Data port aft...

Page 50: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 18 MN DMD1050TS Figure 3 7 Loopback Functional Block Diagram...

Page 51: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 19 MN DMD1050TS Figure 3 8 Loopback Functional Block Diagram Figure 3 9 Loopback Functional Block Diagram...

Page 52: ...face or generated internally You can select the SCTE Clock Terrestrial or the SCT internal clock The modem also allows you to recover the SCT Clock from the satellite Serial Clock Receive SCR or from...

Page 53: ...he incoming receive satellite clock SCT is sometimes referred to as Internal Timing or Send Timing ST If the satellite clock is lost the modem will switch over to the Internal Clock automatically and...

Page 54: ...erence J9 SMA Female This is not actually a clock but does have some clocking implications When the external reference is used the master oscillator in the DMD1050TS is locked to the external referenc...

Page 55: ...transmitted to the satellite When the signal is received and demodulated by the Receiving Modem it is fed to a Viterbi Decoder for the first layer of error correction After error correction is done b...

Page 56: ...2 7 126 112 7 126 112 7 126 112 7 126 112 7 126 112 7 0 125 0 125 0 125 0 125 0 125 0 125 0 125 0 125 4 4 4 4 4 4 4 4 115 58 29 19 15 10 8 5 IDR With 96 Kbps O H 1544 2048 6312 8448 225 205 10 219 201...

Page 57: ...PC on one side of the link will activate AUPC on the distant end of the link It is necessary that both the Modulator and Demodulator be set to the applicable framing for AUPC options to be editable an...

Page 58: ...to the remote modem constantly When the remote modem sees the drop in the Eb No it begins to raise its output power slowly and continues to do so until the Target Eb No is restored at the local site W...

Page 59: ...and commands to the local modem to increase or decrease the local transmit power EF AUPC When configured for EF AUPC this setting is compared against the local received Eb No and commands to the remot...

Page 60: ...ble EFDATA Enables Disables the AUPC to function remotely LOOPBACK Enabled Disabled Loop back test over satellite link Tx 2047 TEST BER Enabled Disabled Initiates 2047 Test pattern Bit Error Rate Test...

Page 61: ...ly An Overhead Channel Service Channel Async Channel or in IESS terminology an ES to ES Data Channel The basic frame structure used by the multiplexer is that specified in the IESS 309 Standard result...

Page 62: ...200 640 320 128 2400 768 384 192 4800 896 448 256 4800 1024 512 320 9600 1152 576 384 9600 1280 640 448 9600 1408 704 512 9600 1536 768 576 9600 1664 832 640 19200 1792 896 704 19200 1920 960 768 1920...

Page 63: ...of the ES to ES Data Channel in a Standard IBS Mode are raw channels operating at the specific bit rate as controlled by the data channel rate without buffering In addition no clocks are provided wit...

Page 64: ...e J3 is a 10 pin Dual Row header The data interface can be configured for RS232 or RS485 via the Web Browser or Terminal Screen 3 17 1 SCC Framing Structure Each SCC frame consists of A 10 bit synchro...

Page 65: ...approximate it The basic calculation of this rate is shown Aggregate Date Rate User Data Rate In Band Rate In Band Rate Control Ratio As an example given these parameters User Data Rate 1 024 000 bps...

Page 66: ...4 6 312 000 19 200 1 3 6 337 606 1 004 6 312 000 19 200 1 1 6 350 418 1 006 3 17 4 Actual Overhead Rate Calculation The modem calculates the minimum in band rate to limit the size of the user data slo...

Page 67: ...request the rate of in band data for the overhead channel This sets the overhead amount only The actual amount of data that can be passed through the overhead channel will be set under ES Baud Rate 4...

Page 68: ...e Setting Symbol Rate 9 6 1 1 300 6800 9 6 1 2 300 6700 9 6 1 3 300 6667 9 6 1 4 300 6650 9 6 1 5 300 6641 9 6 1 6 300 6634 9 6 1 7 300 6629 9 6 1 1 9600 19200 9 6 1 2 9600 17067 9 6 1 3 9600 15543 9...

Page 69: ...a DATA RATE which is where you set the serial interface data rate Run only Ethernet by setting an ETH RATE and then setting DATA RATE to 0 Run only serial by setting a serial rate for DATA RATE and t...

Page 70: ...r all Turbo encoded data is also provided Turbo codes come extremely close to achieving the absolute maximum channel capacity in bits per second for a given transmit power level For traffic that can t...

Page 71: ...engines AES keys and counters 3 20 1 Traffic Encryption and Decryption Keys and Key Generation The AES key and the initial counter value of the counter are negotiated using the key negotiation algori...

Page 72: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 40 MN DMD1050TS Figure 3 13 Traffic Encryption Key Negotiation...

Page 73: ...eral Unified Model Elliptic Curve Cryptography Cofactor Diffie Hellman C 2 0 ECC CDH as specified in the elliptic curve parameters section of NIST SP 800 56A 3 3 20 1 2 1 Key Derivation Once the share...

Page 74: ...The Crypto Officer Administrator can Load software Load key material Configure operating parameters Monitor performance The Crypto Officer Administrator must log in from the front panel or the handhe...

Page 75: ...vates the new features 3 22 Strap Codes The Strap Code is a quick set key that sets many of the modem parameters For quick setup of the DMD1050TS Strap Codes are very helpful When a Strap Code is ente...

Page 76: ...DMD1050TS Satellite Modem Board Revision 1 Theory of Operation 3 44 MN DMD1050TS BLANK PAGE...

Page 77: ...wise 4 1 DMD1050TS Connections All DMD1050TS connections are made to labeled connectors located on the Modem Board See Figure 4 1 Figure 4 2 Figure 4 3 and Figure 4 4 You must use the correct connecto...

Page 78: ...dem Board Revision 1 Rear Panel Interface 4 2 MN DMD1050TS Figure 4 1 DMD1050TS Front View Figure 4 2 DMD1050TS Rear View J3 Pin 1 J3 BUC LNB INPUT POWER J2 SMA OPT F RX L BAND J6 COMPACT FLASH CARD J...

Page 79: ...1 Rear Panel Interface 4 3 MN DMD1050TS Figure 4 3 RF Board PL 0021834 J10 TWIN RJ45 ETHERNET DATA J11 RJ45 M C HIGH STABILITY OSCILLATOR J9 SMA FEMALE J16 INPUT POWER 24V J2 SMA OPT F RX L BAND J6 C...

Page 80: ...DMD1050TS Satellite Modem Board Revision 1 Rear Panel Interface 4 4 MN DMD1050TS Figure 4 4 Baseband Modem Board PL 0022534...

Page 81: ...gnal Name Signal 1 Ground GND 2 Ground GND 3 24 Volts DC 4 24 Volts DC 4 4 BUC LNB Power Input J3 The Block Up Converter BUC and LNB input connector allows you to inject DC voltage externally for the...

Page 82: ...1 05 7 G D Table 4 3 ASYNC Remote Ports J3 Pin No Signal Name Signal Direction 1 RX_ASYNC_B 485 RXD_B Output 2 RX_ASYNC_A 485 RXD_A Output 3 TX_ASYNC_B 485 TXD_B Input 4 TX_ASYNC_A 485 TXD_A Input 5 R...

Page 83: ...e Modem Board Revision 1 Rear Panel Interface 4 7 MN DMD1050TS Table 4 4 Default Reset connections 3 Pin male Connector JP1 JP2 Install Shunt Jumper Between Pins No Pin 1 2 Figure 4 5 Default Shorting...

Page 84: ...2 Request To Send B RS B Input 13 Ground GND 14 Data Terminal Ready A TR A Input 15 Receiver Ready A RR A Output 16 Demodulator Fault DF Output 17 Receive Timing B RT B Output 18 Data Mode B DM B Outp...

Page 85: ...ut or output analog interface KEYLOAD_A Input Output Input Per EIA 485 Specification Sensitivity VThH 1 6V VThL 1 6V Min Input Resistance 1 73K Output Per EIA 485 Specification VOUT 1 5V to 5 0V with...

Page 86: ...DMD1050TS Satellite Modem Board Revision 1 Rear Panel Interface 4 10 MN DMD1050TS BLANK PAGE...

Page 87: ...5 2 Troubleshooting First examine all interface signals for correct operation If a unit is suspected of a defect in field operations after that replace the unit with another known working DMD1050TS If...

Page 88: ...for data 5 2 1 2 Major Rx Alarms Alarm Possible Cause FPGA CFG Shows a receive FPGA hardware failure DSP CFG Shows a receive DSP failure SIGNAL LOCK Shows that the demod is unable to lock to a signal...

Page 89: ...am Framing is not DVB Encryption TRANSEC Module is enabled but not synchronized 5 2 1 5 Common Major Alarms Alarm Possible Cause TERR FPGA CFG Shows an Interface Card FPGA configuration failure likely...

Page 90: ...are grouped into Transmit and Receive Alarms Transmit and Receive alarms are completely independent 5 2 2 1 2 Minor Alarms Minor Alarms mean that a problem can persist outside the modem such as loss o...

Page 91: ...SK 5 16 2 4 3 125 BPSK 21 44 2 4 4 773 BPSK 1 2 2 4 5 0 BPSK 3 4 3 6 7 5 BPSK 7 8 4 2 8 75 QPSK Uncoded 9 6 20 0 QPSK 21 44 4 8 9 545 QPSK 1 2 4 8 10 0 QPSK 2 3 6 4 13 333 QPSK 3 4 7 2 15 0 QPSK 7 8 8...

Page 92: ...01 16APSK 3 4 256 29 3561 16APSK 7 8 256 34 1451 16APSK 19 20 256 37 0081 6 1 3 Non DVB Modes Non DVB Modes Modulation Code Rate Min Data Rate Max Data Rate BPSK NONE 4800 10000000 BPSK VIT 1 2 2400 5...

Page 93: ...5362 QPSK EBEM TURBO 2 3 64000 13180497 QPSK EBEM TURBO 3 4 64000 14811320 QPSK EBEM TURBO 7 8 64000 17252747 QPSK EBEM TURBO 19 20 64000 18716185 OQPSK NONE 9600 20000000 OQPSK VIT 1 2 4800 10000000...

Page 94: ...91268 16APSK EBEM TURBO 2 3 256000 26149903 16APSK EBEM TURBO 3 4 256000 29356346 16APSK EBEM TURBO 7 8 256000 34144709 16APSK EBEM TURBO 19 20 256000 37008159 6 1 4 DVB Modes 187 Mode Modulation Code...

Page 95: ...8PSK TRE 2 3 8848 18431372 8PSK TRE 5 6 11059 20000000 8PSK TRE 8 9 11797 20000000 16QAM TRE 3 4 13271 20000000 16QAM TRE 7 8 15483 20000000 204 Mode Modulation Code Rate Min Data Rate Max Data Rate...

Page 96: ...rious 55 dBc In Band 45 dBc Out of Band On Off Power Ratio 60 dB Scrambler OM 73 CCITT V 35 or IBS FEC Viterbi K 7 at 1 2 3 4 and 7 8 2 3 Rate Trellis Turbo Product Code Optional BPSK 5 16 21 44 QPSK...

Page 97: ...20 dBm or 40 dBc the Lesser FEC Viterbi K 7 at 1 2 3 4 and 7 8 Rate Rate Sequential 1 2 3 4 and 7 8 Optional Trellis 2 3 Turbo Product Code Optional BPSK 5 16 21 44 QPSK OQPSK 21 44 3 4 7 8 8PSK 8QAM...

Page 98: ...r SNMP Remote RS 485 Terminal RS 232 6 6 Terrestrial Interfaces MIL 188 114A All Rates Differential Clock Data DCE Ethernet 2 Port 10 100 Base T Two RJ 45 Auto Crossover Auto Sensing 10 100 Ethernet D...

Page 99: ...8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Viterbi Decoder Specification 1 2 Rate Specification 3 4 Rate Specification 7 8 Rate Typical Performance B O QPSK Unc...

Page 100: ...1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Sequential Decoder Specification 1 2 Rate Specification 3 4 Rate Specification 7 8 Rate Typical Performance B O QPSK Uncoded Theor...

Page 101: ...1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Viterbi Decoder Reed Solomon Specification 1 2 Rate Specification 3 4 Rate Typical Performance B O QPSK Uncoded Theory...

Page 102: ...9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Trellis Decoder Specification 2 3 Rate Specification 2 3 Rate w RS Typical Performance 8PSK Uncoded Theory Figure...

Page 103: ...1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 BER Eb No in dB Viterbi Decoder Specification 3 4 Rate Specification 7 8 Rate Typical Performance 16QAM Uncoded Theory Fig...

Page 104: ...E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 BER Eb No in dB Viterbi Decoder Reed Solomon Specification 3 4 Rate w RS Specification 7 8 Rate w RS Typical Performan...

Page 105: ...7 BER Performance O QPSK Turbo 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Turbo Decoder Specification 1 2 Rate Specification 3 4 Rate Typical Performanc...

Page 106: ...MD1050TS 6 9 8 BER Performance BPSK Turbo 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Turbo Decoder Specification 5 16 Rate Typical Performance B O QPSK U...

Page 107: ...MN DMD1050TS 6 9 9 BER Performance 8PSK Turbo 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB Turbo Decoder Specification 3 4 Rate Typical Performance 8PSK Un...

Page 108: ...050TS 6 9 10 BER Performance 16QAM Turbo 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 BER Eb No in dB Turbo Decoder Specification 3 4 Rate Typical Performance 16Q...

Page 109: ...11 B O QPSK BER Performance LDPC 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB LDPC Decoder Typical Performance B O QPSK Uncoded Theory Specification 1 2 Ra...

Page 110: ...QAM BER Performance LDPC 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB LDPC Decoder Typical Performance 8PSK Uncoded Theory 8QAM Rate 2 3 Specification 8PSK...

Page 111: ...ions 6 21 MN DMD1050TS 6 9 13 16QAM BER Performance LDPC 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB LDPC Decoder Typical Performance 16QAM Uncoded Theory...

Page 112: ...SK MILSTD 188 165B or STANAG Turbo Note Eb No to Bit Error Ratio 77 values based on 16k block size 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB MILSTD 188...

Page 113: ...K MILSTD 188 165B or STANAG Turbo Note Eb No to Bit Error Ratio 77 values based on 16k block size 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB MILSTD 188 1...

Page 114: ...6APSK MILSTD 188 165B or STANAG Note Eb No to Bit Error Ratio 77 values based on 16k block size 1E 9 1E 8 1E 7 1E 6 1E 5 1E 4 1E 3 1E 2 1E 1 0 1 2 3 4 5 6 7 8 9 10 11 12 BER Eb No in dB MILSTD 188 165...

Page 115: ...9 1E 7 6 3 7 0 7 9 5 8 6 5 7 4 1E 8 6 7 7 4 8 4 6 2 6 9 7 9 Table 6 3 B O QPSK BER Performance Viterbi w RS BER Specification dB Typical dB 1 2 Rate 3 4 Rate 7 8 Rate 1 2 Rate 3 4 Rate 7 8 Rate 1E 5...

Page 116: ...9 3 8 4 3 2 6 3 4 4 0 1E 7 3 1 4 1 4 4 2 8 3 7 4 1 1E 8 3 3 4 4 4 5 3 0 4 0 4 2 Table 6 8 BPSK BER Performance Turbo BER Specification dB Typical dB 5 16 Rate 21 44 Rate 5 16 Rate 21 44 Rate 1E 5 2 7...

Page 117: ...Typical dB Specification dB Typical dB 2 3 Rate 3 4 Rate 2 3 Rate 3 4 Rate 2 3 Rate 3 4 Rate 2 3 Rate 3 4 Rate 1E 5 5 4 5 6 5 0 5 2 4 6 5 6 4 2 5 2 1E 6 5 5 5 7 5 1 5 3 4 7 5 7 4 3 5 3 1E 7 5 6 5 8 5...

Page 118: ...1 6 8 1E 6 3 2 3 95 4 45 5 6 7 3 2 8 3 55 4 05 5 2 6 9 1E 7 3 3 4 0 4 5 5 7 7 4 2 9 3 6 4 1 5 3 7 0 1E 8 3 4 4 1 4 6 5 8 7 5 3 0 3 7 4 2 5 4 7 1 Table 6 16 8PSK BER Performance MIL STD 188 165B or ST...

Page 119: ...E 6 4 8 6 6 7 5 8 7 10 7 4 4 6 2 7 1 8 4 10 4 1E 7 4 9 6 7 7 6 8 8 10 8 4 5 6 3 7 2 8 5 10 5 1E 8 5 0 6 8 7 7 8 9 10 9 4 6 6 4 7 3 8 6 10 6 4 K Block 1E 5 5 0 6 8 7 7 8 9 10 8 4 6 6 4 7 3 8 5 10 5 1E...

Page 120: ...n 1 Technical Specifications 6 30 MN DMD1050TS 6 10 ACG Output Voltage The AGC Output Voltage is a function of the Input Power Level in dBm The AGC Output Voltage is found on the Alarm connector Pin 2...

Page 121: ...d Equation 2 Minimum Input Signal Level Below 2500k Symbols per Second 10 log 120 10 2500 Figure 6 18 DMD1050TS Input Level Specification 100 90 80 70 60 50 40 30 20 10 0 10 20 1 10 100 1 000 10 000 I...

Page 122: ...DMD1050TS Satellite Modem Board Revision 1 Technical Specifications 6 32 MN DMD1050TS BLANK PAGE...

Page 123: ...k on the DMD1050TS You must use Microsoft Internet Explorer 6 or greater to use the Web Browser menus 7 3 Graphical User Interface The Graphical User Interface GUI is designed to look like the front p...

Page 124: ...avigation The navigation scheme consists of tabs and submenus that correspond to the front panel top level menu selections When you move the mouse cursor over a tab the tab opens a submenu These subme...

Page 125: ...ware with File Transfer Protocol FTP Modulator LED Lights Transmit On Green The transmitter is on Major Alarm Red The transmit direction has failed and the transmitter is disabled Minor Alarm Yellow A...

Page 126: ...e has links for Technical Specifications Product Options Troubleshooting About Us and Contact us The Introduction page gives an overview of the product It has no configurable items The main menus and...

Page 127: ...Login Screen Example The Login screen shows when you click any of these tabs Password Setup IP Administration or Monitor Control Log in using the correct User Name and Password The DMD1050TS is config...

Page 128: ...7 7 Password Setup Access Page Example Password Setup Access Page Edit User USER 1 USER 2 USER 3 Use to select the user number User Access Group GUEST OPERATOR ADMIN Use to assign the selected user t...

Page 129: ...Page Figure 7 8 Password Setup Preferences Page Example Password Setup Preferences Page User Confirmation DISABLED ENABLED Enable or disable change confirmation to appear for all changes made in the W...

Page 130: ...tion The IP Administration tab offers the following pages to select Modem Addressing Configure Apps Configure PC 7 6 1 IP Administration Modem Addressing Page The Modem Addressing page provides instru...

Page 131: ...g 206 IP Address Mask 255 255 255 000 FF FF FF 00 hex Modem IP Address 192 168 0 238 C0 A8 00 EE Server IP Address 192 168 000 101 C0 A8 00 65 Router IP Address 192 168 000 102 C0 A8 00 66 IP Address...

Page 132: ...em Board Revision 1 Web Browser 7 10 MN DMD1050TS 7 6 2 IP Administration Configure Apps Page The Configure Apps page provides instructions to configure applications Figure 7 10 IP Administration Conf...

Page 133: ...ication to access the device control portion of the MIB These OIDs are used to control the devices satellite link and operation Trap Version V1 default V2 This controls the type of message format used...

Page 134: ...response if a change is made to the modem output User 1 User 2 User 3 Access Group NO GROUP GUEST OPER ADMIN NO GROUP Denies all access GUEST Guests can access most of the site to see modem parameter...

Page 135: ...DMD1050TS Satellite Modem Board Revision 1 Web Browser 7 13 MN DMD1050TS Table 7 4 Terminal and Remote Port Parameters Type VT100 Baud rate 19200 Interface RS232 Remote control Terminal...

Page 136: ...te Modem Board Revision 1 Web Browser 7 14 MN DMD1050TS 7 6 3 IP Administration Configure PC Page The Configure PC page provides instructions to configure the PC Figure 7 11 IP Administration Configur...

Page 137: ...ions that are monitored and or controlled The Monitor and Control menu has the following submenus Transmit Receive Interface Monitor Alarms System Test 7 7 1 Transmit Menu The Transmit menu has the fo...

Page 138: ...uick set key that sets many modem parameters See Appendix G Frequency MHz 950 2050 MHz Use to enter the Modulator IF Output Frequency of the modem in 1 Hz increments Power dBm 0 to 25 dBm 0 to 45 dBm...

Page 139: ...uence number Table 7 5 Network Specifications Network Specs Data Rates Framing Scrambler Spectrum MIL 188 165A 9 6 K 20 0 Mbps None OM73 MIL 188 165A IDR IESS 308 optional 1 544 2 048 6 312 8 448 Mbps...

Page 140: ...e bps Set the Data Rate in bps steps See the technical specifications for data rates Symbol Rate sps Use to view the Symbol Rate Inner FEC Viterbi None 1 2 3 4 7 8 Sequential 1 2 3 4 7 8 CSEQ 3 4 CSC...

Page 141: ...Turbo Contact Comtech EF Data for availability Differential Coding DISABLE ENABLE Enable or disable the Differential Encoder An enabled encoder ensures correct phase lock This may not be adjustable in...

Page 142: ...d VOICE X2 DATA 64KBPS IDR ESC Channel used for Voice or 64 K data channel Async Inband Rate 75 150 300 600 1200 2400 4800 9600 19200 38400 57600 115200 Use to select the Async Inband Rate SCC Inband...

Page 143: ...he embedded overhead channel EBEM Overhead Rate OFF 8K 16K 24K 32K 40K 48K 56K 64K Future option Use to select the overhead channel bandwidth EBEM Encryption Option DISABLE ENABLE Future option Enable...

Page 144: ...Figure 7 14 Transmit Reed Solomon Page Example Transmit Reed Solomon Page Reed Solomon Control DISABLED ENABLED Enable or disable the R S Encoder Interleaver Depth 4 8 12 Use to select the R S interle...

Page 145: ...to 255 Use to select the time delay to occur after power up before the Tx Carrier can be enabled This allows time for the BUC to stabilize 10 MHz BUC Reference DISABLED ENABLED Enable or disable the 1...

Page 146: ...m Board Revision 1 Web Browser 7 24 MN DMD1050TS Transmit ODU BUC Page Test Status Not Available on the DMD1050TS Pass Thru Command Not Available on the DMD1050TS BUC Output DISABLED ENABLED Enable or...

Page 147: ...el high enough to re establish communications regardless of rain fade EFDATA Enables EFDATA Local AUPC Function In the event that the remote or local demodulator losses lock the output power level wil...

Page 148: ...red for EBEM AUPC the maximum Transmit Power is the highest power setting that will be used when the remote modem commands an increase of the Transmit Power from the Local modem EF AUPC When configure...

Page 149: ...the maximum transmit power setting is used Target EsNo dB 1 0 to 25 dB Read only Set the desired Eb No for the local receiver EBEM AUPC When configured for EBEM AUPC this setting is compared against...

Page 150: ...tern Test Mode of the remote modem BER is reported from the 1x10 5 to 1x10 7 in tenth decade steps If the pattern does not synchronize or is out of range NO DATA is displayed When modems are configure...

Page 151: ...able the ITA function Waveform Mask Properties BPSK o 1 2 o 2 3 o 3 4 o 7 8 o 19 20 QPSK o 1 2 o 2 3 o 3 4 o 7 8 o 19 20 8 PSK o 1 2 o 2 3 o 3 4 o 7 8 o 19 20 16 APSK o 1 2 o 2 3 o 3 4 o 7 8 o 19 20 U...

Page 152: ...ion the Network Spec command sets several parameters in the modem The purpose is to eliminate keystrokes and compatibility problems Additionally data rates not covered by the selected specification ar...

Page 153: ...necessary Fast Acquisition DISABLED ENABLED Disable or enable the Rx Fast Acquisition capability for low symbol rates Carrier Input Level Limit 30 to 90 dBm should this be 90 or 90 Use to set the min...

Page 154: ...08 optional 1 544 2 048 6 312 8 448 Mbps 96 Kbps IDR V 35 Intelsat IBS IESS 309 optional 1 544 2048 1 15 IBS IESS 309 Intelsat Drop Insert optional n x 64 n 1 2 3 4 5 6 8 10 12 15 16 20 24 30 1 15 IBS...

Page 155: ...ecifications Use the keypad to set the Data Rate in bps steps See the technical specifications for data rates Symbol Rate sps Use to view the Symbol Rate Inner FEC Viterbi None 1 2 3 4 7 8 Sequential...

Page 156: ...Disable or enable the IFEC Interleave This is valid only for Radyne turbo codes TPC 495 and TPC 793 This is available only for Radyne legacy Turbo Contact the factory for availability Differential Cod...

Page 157: ...NONE 188 204 DVB Only Data Polarity INVERT NONE INV TERR DATA INV BASEBAND INV TERR BASE Use to invert the Rx Data polarity Symbol Pair NONE SWAPPED NORMAL optional Use to swap the I Q Channels BPSK M...

Page 158: ...TL RATIO is the ratio of overhead in band data to synchronizing words EBEM Ethernet Rate XXXXXXXXX Future option EBEM Embedded Channel DISABLE ENABLE Future option Enable or disable the embedded overh...

Page 159: ...Enable or Disable the Reed Solomon Encoder Reed Solomon N Value Refer to AN177 for custom Reed Solomon N K combinations Shows the N value in use of the Reed Solomon codes Reed Solomon K Value Refer to...

Page 160: ...DMD1050TS 7 7 2 4 Receive CNC Page The DMD1050TS does not support CNC Figure 7 21 Receive CNC Page Example Receive CNC Page CnC Mode DISABLED This will always show DISABLED Min Search Delay msec N A N...

Page 161: ...QUENCY to show correctly The LNB LO can be higher or lower in frequency than the LNB output frequency If the LNB LO is higher in frequency then you must enter HIGH SIDEBAND LNB Voltage DISABLED ENABLE...

Page 162: ...sable the ITA Control Margin dBm 0 to 2 00 dB Sets link margin when operating in ITA mode Hysteresis dBm 0 to 2 00 dB Sets the variation in Es No needed to trigger a waveform transition Waveform Mask...

Page 163: ...ard Revision 1 Web Browser 7 41 MN DMD1050TS Receive ITA Page Highlighted Waveform Mask Indicate the Following Unattainable Attainable Current Displays the status of each waveform when ITA is engaged...

Page 164: ...to select the Clock Polarity for the Tx Terrestrial Clock relative to the Tx Data Select Auto to cause the unit to detect wrong polarity and correct it automatically SCT Clock Source INTERNAL SCT SCR...

Page 165: ...Strict Priority makes sure that the higher priority traffic transmits before the lower priority traffic CAUTION Strict Priority can severely limit lower priority traffic ETH HDLC RADYNE COMTECH MANAG...

Page 166: ...0 dB Use to select ESC Voice Channel Gain Only displayed when IDR NETWORK and VOICE Channel are selected Esc Ch 2 Gain 20 to 10 dB Use to select ESC Voice Channel Gain Only displayed when IDR NETWORK...

Page 167: ...T Internal RX SAT EXT BNC EXT IDI Use to assign priorities to the clock sources The highest priority is 1 and 5 is the last resort Source 5 SCTE External SCT Internal RX SAT EXT BNC EXT IDI Use to ass...

Page 168: ...ce Source in MHz BB Minor Alarm Relay Usage IBS ALMs IBS MNR ALMs IBS MNR MJR ALM RTS PROMPT AHO 1 1 SWITCH IBS ALMs Only supports IBS prompt and service alarms Note The following menus are only suppo...

Page 169: ...the demodulator Raw BER Read only this shows the estimated channel error rate before decoding measured by the modem Corrected BER Read only this shows an estimated corrected bit error rate of the mod...

Page 170: ...e measured voltage of the 1 5 Volt Tx power bus inside the modem 1 5V Rx Supply Read only this shows the measured voltage of the 1 5 Volt Rx power bus inside the modem 3 3V Supply Read only this shows...

Page 171: ...thernet Packet Error Rate Read only this shows the satellite Packet Error Rate It is visible only when the interface type is Ethernet Reset Ethernet Packet Stats Use to reset the Ethernet packet stati...

Page 172: ...his shows the status of the LAN Port 2 Down the link is down Unresolved cannot agree on connection speed 10 Mbps Half connected at 10 Base T Half Duplex 10 Mbps Full connected at 10 Base T Full Duplex...

Page 173: ...nitor Event Page Delete All Use to delete all events in the buffer Event Type I Informational Y Yellow alarm means a transmit or receive warning condition R Red alarm means a transmit or receive failu...

Page 174: ...ard Revision 1 Web Browser 7 52 MN DMD1050TS 7 7 4 4 Monitor CNC Page Figure 7 30 Monitor CNC Page Example Monitor CNC Page Not available on the DMD1050TS CnC Delay usec N A N A CnC Freq Offset KHz N...

Page 175: ...fig Current Latched Masked checkmark Unmasked no check This shows if a transmit DSP configuration failure exists Sct Clock PLL Current Latched Masked checkmark Unmasked no check This shows if the Tx S...

Page 176: ...Current Latched Masked checkmark Unmasked no check This glows when no Terrestrial Clock activity exists Terr Data Act Current Latched Masked checkmark Unmasked no check This glows when no Tx Data act...

Page 177: ...MN DMD1050TS Alarms Transmit Page TPC Conflict Chk Current Latched Masked checkmark Unmasked no check Indicates that the TPC parameters are not configured correctly FORCE ALARM TEST Use to force alarm...

Page 178: ...Unmasked no check This shows if a receive FPGA hardware failure exists DSP Config Current Latched Masked checkmark Unmasked no check This shows if a receive DSP failure exists Signal Lock Current Lat...

Page 179: ...asked no check This shows if the interface card is faulted and is not passing data It glows only when the Ethernet Card is installed and the Ethernet Interface is selected MINOR ALARMS Buffer Underflo...

Page 180: ...no check Indicates that the TPC parameters are not configured correctly OFEC Lock Current Latched Masked checkmark Unmasked no check This shows if the Reed Solomon Decoder is not locked Interleaver C...

Page 181: ...Unmasked no check Indicated that the embedded channel is enabled but not in synchronization Ebem Encrypt Current Latched Masked checkmark Unmasked no check Indicated that the encryption is enabled but...

Page 182: ...ck This shows if there is a Turbo Codec Card FPGA configuration failure Codec Dev Cfg Current Latched Masked checkmark Unmasked no check This shows if there is a Turbo Codec Card ASIC configuration fa...

Page 183: ...ent Latched Masked checkmark Unmasked no check This shows if the measured voltage of the 3 3 Volt power bus that is inside the modem is xxx 5V Supply Current Latched Masked checkmark Unmasked no check...

Page 184: ...inal Screens and RLLP Physical contacts are not available for the backward alarms Alarms Common Page IDR ALARMS IDR Backwards 1 SAT Alarm Xmitted Received SAT Control Standard Force On Force Off IDR B...

Page 185: ...ard Force On Force Off T1E1 Backward SATTERR Alarm Xmitted Received Terr Control Standard Force On IBS Prompt Xmitted Terr Control Standard Force On IBS Service Xmitted Terr Control Standard Force On...

Page 186: ...nal Remote Page Example System Terminal Remote Page Remote Port Control COMPUTER TERMINAL Use to select either terminal RS 232 control or remote port M C RS 232 485 control Terminal Emulation VIEWPOIN...

Page 187: ...eb Browser 7 65 MN DMD1050TS System Terminal Remote Page Remote Baud Rate 150 300 600 1200 2400 4800 9600 19200 38400 57600 115200 Use to enter the Remote Port Baud Rate Remote Interface RS 232 RS 485...

Page 188: ...age Firmware This shows the installed firmware revision M C Revision This shows the installed Monitor and Control revision M C Time Stamp This shows the Date and Time the Modem firmware was built IF B...

Page 189: ...DMD1050TS Satellite Modem Board Revision 1 Web Browser 7 67 MN DMD1050TS 7 7 5 3 System Features Page Figure 7 37 System Features Page Example...

Page 190: ...t to each feature is a series of symbols that show feature status Installed No hardware available requires hardware for upgrade Feature is in Demo Mode and will expire Key Code Required Call customer...

Page 191: ...sing the modem s loopback capabilities with the Ethernet data interface To run any type of data test with an Ethernet interface you must use two modems connected back to back Do not use one modem and...

Page 192: ...X IF TERR TX RX BASEBAND TX RX Pattern Ber NO SYNC nnnn x 10 n This shows the measured Bit Error Rate for the received test pattern Pattern Error Count NO SYNC nnnn x 10n This shows the number of erro...

Page 193: ...DMD1050TS 7 7 6 2 Test I Q Plot Page The I Q Plot page shows the RX I Q sampled data as seen by the receiver Figure 7 39 Test I Q Plot Page Example Test I Q Plot Page PICK A COLOR RED GREEN START Clic...

Page 194: ...of the selections and then it will appear in green on the AVERAGING button RESOLUTION Low Medium High Hover over the RESOLUTION button to display the selections Click on one of the selections and then...

Page 195: ...DMD1050TS Satellite Modem Board Revision 1 Web Browser 7 73 MN DMD1050TS 7 8 TRANSEC Module HTTP Interface Refer to Chapter 8 for detailed information on the TRANSEC Module HTTP Interface...

Page 196: ...DMD1050TS Satellite Modem Board Revision 1 Web Browser 7 74 MN DMD1050TS BLANK PAGE...

Page 197: ...Base Modem Thus a secure HTTPS connection to the TRANSEC Module allows secure user access to all Base Modem parameters through this indirect proxy connection The secure management interfaces supporte...

Page 198: ...or Connects to the Base Modem HTTP Interface See Chapter 7 Web Browser for more information Network Operator Not Available Once the login page opens Crypto Officer appears as the default On the Login...

Page 199: ...SSL 2 0 and SSL 3 0 b Enable the Transport Layer Security TLS 1 0 3 Make sure to enable SSL again once troubleshooting is finished Figure 8 1 Tools Internet Options Advanced Security Settings 8 3 2 H...

Page 200: ...Board Revision 1 TRANSEC Module HTTPS Interface 8 4 MN DMD1050TS 8 4 TRANSEC Module HTTPS Interface Page Descriptions 8 4 1 Configure The Configure page provides configuration and management functions...

Page 201: ...n the set of 26 TEKs Note the following The Next TEK button is disabled when the module is in secondary mode and the current TEK mirrors the TEK the connected primary modem uses The TEK only increment...

Page 202: ...ctivate Future Key button is active only when the following conditions are met 1 The modem is in Primary mode see Encryption Mode explained below 2 The Current TEK is greater than 1 Future Seed Key wr...

Page 203: ...y the TRANSEC Module using the current TEK This encrypted data is then delivered to the base modem for transmission regardless of the state of the receiving modem Three user defined parameters must ma...

Page 204: ...ch the subnet of the Secure Management IP If it does not then the Gateway IP text box will default to 0 0 0 0 Click Update Settings to apply changes made to any of these parameters 8 4 1 5 Crypto Offi...

Page 205: ...k Generate New Host Key to generate a new host key that uniquely identifies the TRANSEC Module After doing this SSH clients that have connected to the TRANSEC Module before will usually note or warn t...

Page 206: ...ge 8 4 2 1 Encryption Parameters Item Description AES256 Firmware Version Identifies the version of the AES 256 core Encryption Frame Length Displays the currently configured AES 256 frame length Boar...

Page 207: ...2 3 Receive Status Item Description RX CRC Errors Displays the count of received CRC errors RX Frame Count Displays the number of received AES 256 frames RX Status Displays the value of the Rx Status...

Page 208: ...ages Logging Level This drop down menu controls the maximum filtering level of displayed messages Choices are Errors Only Errors and Warnings and All Information Click Save to save the settings 8 4 3...

Page 209: ...rror condition that the system should be able to recover from without affecting the operation of the system e g encountering software bug etc Such events are not recorded into the Events Log Moderate...

Page 210: ...Module Bootrom Info Boot Loader version information Image 1 Info Slot 1 firmware image version information Image 2 Info Slot 2 firmware image version information Running Image Indicates the active fi...

Page 211: ...associated with the TRANSEC Module firmware update process 8 4 5 2 HTTPS Certificate Use this area to upload an X509 private key and certificate in PEM format to replace the current HTTPS certificate...

Page 212: ...from New Folder to temp or another convenient unused name Assuming temp works a c temp folder should now be created For Windows Command line Click Start on the Windows taskbar and then click the Run...

Page 213: ...sults should confirm whether or not the module is connected and communicating 8 Initiate a secure Web session with the DMD1050TS TRANSEC Module via its HTTPS Interface The example uses Internet Explor...

Page 214: ...the update file and then click Open The filename should appear in the Replace stand by firmware text box d Click Upload to begin the Firmware Application Process 10 Wait while the file transfers After...

Page 215: ...than the TRANSEC Module bulk firmware i e FW 0020567x bin Upon successful completion of transfer the progress bar shows 100 11 On the Firmware page verify that the newly uploaded firmware is reported...

Page 216: ...DMD1050TS Satellite Modem Board Revision 1 TRANSEC Module HTTPS Interface 8 20 MN DMD1050TS BLANK PAGE...

Page 217: ...out the command functionality 9 1 1 SSH User Access When connecting via SSH you must have network connectivity to the TRANSEC Module This connectivity can be via a local LAN a remote LAN or via a sate...

Page 218: ...DMD1050TS Satellite Modem Board Revision 1 TRANSEC Module SSH CLI Operation 9 2 MN DMD1050TS Figure 9 1 Login screen and Main Menu Examples...

Page 219: ...This means the field is a read only status informational message No user action is required for this item Logout of Administration Session L Found at the bottom of the screen Allows you to log out of...

Page 220: ...active as long as the modem remains in operation however unsaved changes are lost if for example the unit loses power Use the S command on any menu to save changed parameters A prompt asks you to conf...

Page 221: ...M The Module Status screen has no other menus This read only screen shows the TRANSEC Module s existing operating parameters Event Log E Opens the Event Log screen Use it to monitor and control operat...

Page 222: ...Identifies the modem s active Encryption Mode as Primary or Secondary Active Encryption Key A Opens the Active Encryption Key Menu Future Encryption Key F Opens the Future Encryption Key Menu Encrypt...

Page 223: ...eed Key to generate a TEK when the TRANSEC Module is given a Passphrase Confirm Seed Key C Confirm the active Seed Key Seed Key fields RO Shows the status of the active Seed Key in real time Passphras...

Page 224: ...ture is shown here Seed Key K Enter a 32 character future Seed Key to generate a TEK when the TRANSEC Module is given a Passphrase Confirm Seed Key C Confirm the future Seed Key Seed Key fields RO Sho...

Page 225: ...ating Mode O Prompts you to set the Operating Mode operation 0 Primary 1 Secondary Frame Length F Specify the length of the AES 256 encryption frame from 1 to 255 Zeroize All Keys Z Resets all encrypt...

Page 226: ...ddress as necessary Note If this address is changed you must repeat the login process for the SSH interface using the new IP address to regain access to the TRANSEC Module SSH CLI Subnet Bits B Change...

Page 227: ...cription Crypto Officer User Name U Enter the desired User Name Crypto Officer Password P Enter the desired Password Confirm Password C Confirm the Password just entered Password Fields RO Shows the s...

Page 228: ...Example Table 9 8 SSH Console Menu Options Menu Options Fields Entry Description Host Key Signature RO Shows the key signature or fingerprint which helps to identify the TRANSEC Module when connecting...

Page 229: ...screen M Figure 9 10 Module Status Screen Example The read only Module Status screen shows the operating parameters for the TRANSEC Module Interface AES 256 Version Encryption Frame Length Operating M...

Page 230: ...information collected for the Events Log 0 Errors Only 1 Errors and Warning 2 All Information View Event Log V Shows the tally of events logged since the last time the Log was cleared Clear Event Log...

Page 231: ...t From B Select the firmware boot source for modem operations 0 Newest This selects the most current firmware residing in either Slot 1 or Slot 2 automatically 1 Slot 1 This selects the firmware in th...

Page 232: ...MN DMD1050TS 9 2 8 Comtech EF Data Information screen Z Figure 9 13 Comtech EF Data Information Screen Example The read only Comtech EF Data Information screen shows basic contact information for Com...

Page 233: ...e DMD1050TS can be customized for specific requirements Most modifications or customizations occur through firmware and or software changes These are examples of the customization types available Cust...

Page 234: ...DMD1050TS Satellite Modem Board Revision 1 Appendix A A 2 BLANK PAGE...

Page 235: ...while reprogramming modulator functions that can change the output spectrum After the reprogramming you must turn the output on manually B 4 Carrier Auto In the user interface turn modulator output of...

Page 236: ...r Yes to re enable output When using the terminal turn the modulator off while reprogramming modulator functions that can change the output spectrum After reprogramming you must turn the output on man...

Page 237: ...d router IP addresses 1 Use the dumb terminal System menu 2 Select the TCP IP sub menu 3 Enter the TCP IP menu These sub menus will show but their order can vary C 2 1 Boot Mode Submenu Use the BootMo...

Page 238: ...the information to the non volatile memory The modem restores the saved settings into the correct fields when the power cycles C 2 1 4 IP Test Selection The IP TEST selection is similar to the Defaul...

Page 239: ...72 018 004 250 C 2 7 Router IP Address Submenu This allows you to set up the Network Router IP Address If a router exists on the local network and it is to be used this address must be consistent with...

Page 240: ...he submenus then here is the TCP IP configuration summary for a no router specified setup 1 Boot Mode NON VOL 2 Bootp Server Tag 206 3 Modem Host DMD1050TS 4 IP Address Mask 255 255 0 0 5 Modem IP Add...

Page 241: ...Connect the Modem Ethernet Cable Directly to a Computer without a Network Make sure the Computer TCP IP is configured correctly You can use this setup procedure as a guide For Windows 2000 or XP Class...

Page 242: ...the Properties button Figure C 3 Local Area Connection Properties Box 11 Select Use the following IP Address 12 Enter an IP Address that is offset by five or so numbers from the equipment address The...

Page 243: ...ppendix C C 7 MN DMD1050TS Some computers require the computer to be restarted for the changes to take effect Figure C 4 Internet Protocol TCP IP Properties Box 15 To reconnect the computer to a netwo...

Page 244: ...xxx xxx where xxx xx xxx xxx is the IP Address of the equipment to be tested Microsoft Windows XP Version 5 1 2600 C Copyright 1985 2001 Microsoft Corp C ping 172 18 100 215 3 If the ping succeeds the...

Page 245: ...timed out Request timed out Request timed out Request timed out Ping statistics for 172 18 100 215 Packets Sent 4 Received 0 Lost 4 100 loss 5 For an unsuccessful response check these items a The corr...

Page 246: ...DMD1050TS Satellite Modem Board Revision 1 Appendix C C 10 MN DMD1050TS BLANK PAGE...

Page 247: ...have difficulty getting access to the Web Browser interface install the Default Jumper Plug that will change the IP addresses to an accessible address To reset IP addresses install the Default Plug be...

Page 248: ...e D 1 Ethernet Connection 3 Do a PING test to make sure there is communication between the modem and the computer Example ping 192 168 0 238 If everything is functioning correctly replies from the mod...

Page 249: ...MN DMD1050TS See Figure D 3 The Introduction page shows general information about the modem features capabilities and available options Technical specifications and product options are available in a...

Page 250: ...ab and the modem requests authentication via a User Name and Password The DMD1050TS is configured initially with these defaults User Name admin Password admin The modem allows for specific administrat...

Page 251: ...ave the same subnet mask Set this field before changing the Modem or Router Address See Figure D 5 1 Configure the modem with the new subnet addresses a From the modem introduction page click the IP A...

Page 252: ...e Figure D 6 1 Configure the computer with the new subnet addresses a Do a ping test to make sure there is communication between the modem and the computer Example ping 192 168 0 238 b If communicatio...

Page 253: ...The user name can have up to 14 alpha and numeric characters Enter Alpha characters using the up and down arrow keys Enter Numeric characters using the number keys Web User Authentication Password Acc...

Page 254: ...he logon popup 3 Press Enter 4 Select USER1 USER2 or USER3 from the drop down Edit User menu The applicable User Name and access rights are updated on the screen 5 Select a new User Name if desired an...

Page 255: ...Address Mask 255 000 000 000 FF 00 00 00 hex Modem IP Address 010 000 000 001 C0 A8 00 EE hex Server IP Address 010 001 001 001 0A 01 01 01 hex Router IP Address 010 000 001 001 0A 00 01 01 hex BOOTp...

Page 256: ...DMD1050TS Satellite Modem Board Revision 1 Appendix D D 10 MN DMD1050TS BLANK PAGE...

Page 257: ...al Housing J3 J16 7 TM CPF08 Terminal crimp 18 24AWG for 2139 J3 J16 E 2 1 J3 J4 Interface Connectors located on PCB J3 Async Interface Connector 10Pin Dual Row Mfg Samtec P N TSW 1 05 7 G D J4 Mil 18...

Page 258: ...s Active Product Name KK Molex Series 2478 Gender Female Wire Size AWG 18 20 22 24 Wire Insulation Diameter 2 79mm 110 max Packaging Bag Physical Contact Brass CuZn Contact Material Thickness 0 27mm 0...

Page 259: ...rrect ports without unnecessary startup delay For more control over traffic the EEI provides additional QoS controls and new features such as port based priorities strict priority queuing and operatio...

Page 260: ...signed dynamically by a Dynamic Host Configuration Protocol DHCP server Because the EEI can be configured to work like a bridge and not like a router the DHCP Requests and Responses required to bring...

Page 261: ...ng a new remote online without disrupting the existing traffic Figure F 3 shows how the DMD50 DMD20 and MD2401 multi demodulator can be used in the same network They provide a large outbound carrier a...

Page 262: ...isruption of the existing traffic Figure F 4 High Speed Mesh DMD 50 52 Mbps 52 Mbps 52 Mbps 52 Mbps Router LAN 1 52 Mbps 52 Mbps 52 Mbps 52 Mbps Figure 4 High Speed Mesh DMD 50 DMD 50 52 Mbps 104 Mbps...

Page 263: ...res no IP configuration or network setup See Figure F 5 When configured with the Ethernet option the MD2401 automatically multiplexes the packets received from the multiple data streams onto a single...

Page 264: ...sy chain capability you can control every modem easily from one central location This is true for modems in complex point to multi point systems as well This all occurs without extensive network setup...

Page 265: ...net Bridge It is what most users require typically Normal QoS uses this packet information When a packet contains an optional IEEE802 3ac tag the EEI uses the IEEE802 1p priority information embedded...

Page 266: ...d because the packet can be retransmitted However there are some cases where the end device must receive the erred packet rather than no packet at all Examples of two such situations include cryptogra...

Page 267: ...0 or DMD2050 to provide a transparent satellite connection at data rates ranging from 4 8 kbps to 20 Mbps EEI can be used with any available FEC and Modulation Type including DVB S EEI offers plug and...

Page 268: ...DMD1050TS Satellite Modem Board Revision 1 Appendix F F 10 MN DMD1050TS BLANK PAGE...

Page 269: ...rambler Type Reed Solomon Modulation Mode 12 2048 16 15 1 2 VIT IBS IBS Dis QPSK CNT 24 56 1 1 2 VIT NONE V 35 IESS Dis QPSK CNT 33 56 1 3 4 VIT NONE V 35 IESS Dis QPSK CNT 34 64 1 1 2 VIT NONE V 35 I...

Page 270: ...Dis QPSK CNT 74 3152 1 3 4 VIT NONE V 35 IESS Dis QPSK CNT 76 3264 1 1 2 VIT NONE V 35 IESS Dis QPSK CNT 81 3264 1 3 4 VIT NONE V 35 IESS Dis QPSK CNT 97 1024 1 1 2 VIT CNT V 35 IESS Dis QPSK CNT 98...

Page 271: ...15 1 2 VIT IBS IBS Dis QPSK CNT 77 1472 16 15 3 4 VIT IBS IBS Dis QPSK CNT 78 1600 16 15 1 2 VIT IBS IBS Dis QPSK CNT 83 1600 16 15 3 4 VIT IBS IBS Dis QPSK CNT 85 1664 16 15 1 2 VIT IBS IBS Dis QPSK...

Page 272: ...DMD1050TS Satellite Modem Board Revision 1 Appendix G G 4 MN DMD1050TS BLANK PAGE...

Page 273: ...ment necessary for this procedure H 4 Upgrade Procedure H 4 1 Find the available features 1 Use the GUI interface 2 Go to System Features 3 Click Features The screen shows all available features Check...

Page 274: ...d demonstration capability To continue after the lock out you must cycle power on the modem 1 Enter the upgrade code from the terminal port a On the Enter Selection Number line type 45 b Press Enter c...

Page 275: ...the Unit ID 1 Use the Terminal interface 2 Go to Main Features 3 Find Feature Id The Feature Id value on the top line is the 12 digit Unit ID Example 1 2 3 4 1 2 3 4 1 2 3 4 The Customer Service repre...

Page 276: ...er Selection Number line type 45 5 Press Enter 6 Use the numeric keypad to enter 0000 0000 0000 7 Press Enter The modem ends the demonstration immediately The feature set reverts to the permanent conf...

Page 277: ...enu Example Each feature has symbols that show its status The symbols include Installed No hardware available Requires hardware for upgrade Feature is in Demo Mode and will expire Key Code Required Ca...

Page 278: ...DMD1050TS Satellite Modem Board Revision 1 Appendix H H 6 MN DMD1050TS BLANK PAGE...

Page 279: ...n With a static traditional FDMA system severe rain fading can cause the total loss of the link and zero throughput ITA keeps the link up with lower information throughput and can yield much higher sy...

Page 280: ...n Code Rate Bits Symbol Typical Eb No Required Es No Selected Test Cases 16APSK 0 95 3 800 10 25 16 05 8PSK 0 95 2 850 9 31 13 86 16APSK 0 875 3 500 8 40 13 84 8PSK 0 875 2 650 7 50 11 69 16APSK 0 75...

Page 281: ...menu Setup N A see ITA submenu Setup N A MODULATOR REED SOLOMON ENABLE DISABLE DISABLE ENABLE DISABLE DISABLE DEMODULATOR NETWORK SPEC NETWORK SPEC EBEM NETWORK SPEC EBEM DEMODULATOR IF FREQUENCY MHz...

Page 282: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 4 MN DMD1050TS Figure I 1 Initial Setup DMD1050TS Modulator IF Figure I 2 Initial Setup DMD1050TS Modulator Data...

Page 283: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 5 MN DMD1050TS Figure I 3 Initial Setup DMD1050TS Modulator ITA Figure I 4 Initial Setup DMD1050TS Demodulator IF...

Page 284: ...emodulator Data Figure I 6 Initial Setup DMD1050TS Demodulator ITA At this point verify that both serial traffic and Ethernet traffic is properly passing through the system Enable and setup the ITA fu...

Page 285: ...ubmenu Setup N A MODULATOR REED SOLOMON ENABLE DISABLE DISABLE ENABLE DISABLE DISABLE DEMODULATOR NETWORK SPEC NETWORK SPEC EBEM NETWORK SPEC EBEM DEMODULATOR IF FREQUENCY MHz 142 5 MHz FREQUENCY MHz...

Page 286: ...d to select the mod code rate 16APSK 7 8 NOT SELECTED SELECTED Used to select the mod code rate 16APSK 19 20 NOT SELECTED SELECTED Used to select the mod code rate Table I 5 Receive ITA Functions Func...

Page 287: ...LECTSED MODULATOR ITA QPSK 1 2 NOT SELECTSED MODULATOR ITA QPSK 2 3 SELECTED MODULATOR ITA QPSK 3 4 NOT SELECTSED MODULATOR ITA QPSK 7 8 NOT SELECTSED MODULATOR ITA QPSK 19 20 NOT SELECTSED MODULATOR...

Page 288: ...DEMODULATOR ITA QPSK 1 2 NOT SELECTSED DEMODULATOR ITA QPSK 2 3 SELECTED DEMODULATOR ITA QPSK 3 4 NOT SELECTSED DEMODULATOR ITA QPSK 7 8 NOT SELECTSED DEMODULATOR ITA QPSK 19 20 NOT SELECTSED DEMODULA...

Page 289: ...NOT SELECTSED MODULATOR ITA QPSK 1 2 NOT SELECTSED MODULATOR ITA QPSK 2 3 SELECTED MODULATOR ITA QPSK 3 4 NOT SELECTSED MODULATOR ITA QPSK 7 8 NOT SELECTSED MODULATOR ITA QPSK 19 20 NOT SELECTSED MOD...

Page 290: ...0 NOT SELECTSED MODULATOR ITA QPSK 1 2 NOT SELECTSED MODULATOR ITA QPSK 2 3 SELECTED MODULATOR ITA QPSK 3 4 NOT SELECTSED MODULATOR ITA QPSK 7 8 NOT SELECTSED MODULATOR ITA QPSK 19 20 NOT SELECTSED MO...

Page 291: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 13 MN DMD1050TS Figure I 7 Initial Setup DMD1050TS Modulator ITA Figure I 8 Initial Setup DMD1050TS Demodulator ITA...

Page 292: ...just uplink power to a moderate value of approximately 16 dB C N at 8 3 MSPS On the receiver set the margin to 1 dB and leave the hysteresis at 0 Next enable the ITA control The Web page status will i...

Page 293: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 15 MN DMD1050TS Figure I 11 DMD1050TS I Q for BPSK 2 3 Figure I 12 DMD1050TS ITA Status for QPSK 2 3...

Page 294: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 16 MN DMD1050TS Figure I 13 DMD1050TS I Q for QPSK 2 3 Figure I 14 DMD1050TS ITA Status for 16APSK 1 2...

Page 295: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 17 MN DMD1050TS Figure I 15 DMD1050TS I Q for 16APSK 1 2 Figure I 16 DMD1050TS ITA Status for 8PSK 3 4...

Page 296: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 18 MN DMD1050TS Figure I 17 DMD1050TS I Q for 8PSK 3 4 Figure I 18 DMD1050TS ITA Status for 16APSK 7 8...

Page 297: ...on 1 Appendix I I 19 MN DMD1050TS Figure I 19 DMD1050TS I Q for 16APSK 7 8 At this point changing the noise source level will dynamically change the selected waveforms You can simulate fades by attenu...

Page 298: ...DMD1050TS Satellite Modem Board Revision 1 Appendix I I 20 MN DMD1050TS BLANK PAGE...

Page 299: ...DMD1050TS Satellite Modem Board Revision 1 Appendix J J 1 MN DMD1050TS Appendix J Compatibility with Other DMD Modems J 1 Compatibility with Other DMD Modems...

Page 300: ...DMD1050TS Satellite Modem Board Revision 1 Appendix J J 2 MN DMD1050TS BLANK PAGE...

Page 301: ...Feature Sequential Feature Sequential Feature 8 4 2 048 Sequential Feature Sequential Feature OQPSK Viterbi 1 2 4 8 10 000 Standard Standard Standard 4 8 30 000 Standard Standard 3 4 7 2 15 000 Standa...

Page 302: ...B Feature 3 4 7 2 13 824 DVB Feature DVB Feature DVB Feature 7 2 13 824 DVB Feature DVB Feature 5 6 8 0 15 359 DVB Feature DVB Feature DVB Feature 8 0 15 359 DVB Feature DVB Feature 7 8 8 4 16 127 DVB...

Page 303: ...7 2 20 000 TPC Feature HW14 Standard 7 8 8 4 17 500 TPC Feature HW 2 TPC Feature TPC Feature 8 4 20 000 TPC Feature HW14 Standard 0 495 64 0 6 132 TPC Feature HW15 64 0 6 132 TPC Feature HW15 0 793 6...

Page 304: ...20 000 8QAM TPC Feature HW16 Standard 16QAM TPC 3 4 14 4 20 000 16QAM TPC Feature HW14 16QAM TPC Feature 16QAM TPC Feature 14 4 20 000 16QAM TPC Feature HW14 Standard 7 8 16 8 20 000 16QAM TPC Featur...

Page 305: ...e HW17 64 52 000 EBEM Feature HW17 Standard 8PSK Turbo 1 2 256 14 8112 EBEM Feature HW17 256 44 454 EBEM Feature HW17 Standard 2 3 256 19 6912 EBEM Feature HW17 256 52 000 EBEM Feature HW17 Standard 3...

Page 306: ...HP LDPC 1 2 4 8 10 000 LDPC Feature HW16 LDPC Feature HW18 LDPC Feature HW20 4 8 20 000 LDPC Feature HW16 LDPC Feature 2 3 6 4 13 333 LDPC Feature HW16 LDPC Feature HW18 LDPC Feature HW20 6 4 20 000...

Page 307: ...eature HW19 LDPC Feature HW20 2 4 1 875 LDPC Feature HW19 DSSS Feature LDPC Feature FACTOR x16 2 4 313 LDPC Feature HW19 LDPC Feature HW20 2 4 937 LDPC Feature HW19 DSSS Feature LDPC Feature HP LDPC O...

Page 308: ...ure HP LDPC OFF 1 2 4 7 9 866 LDPC Feature HW19 LDPC Feature HW20 4 7 9 866 LDPC Feature HW19 DSSS Feature LDPC Feature FACTOR x2 4 7 4 933 LDPC Feature HW19 LDPC Feature HW20 4 7 4 933 LDPC Feature H...

Page 309: ...DPC Feature FACTOR x4 7 0 3 671 LDPC Feature HW19 LDPC Feature HW20 7 0 3 671 LDPC Feature HW19 DSSS Feature LDPC Feature FACTOR x8 7 0 1 836 LDPC Feature HW19 LDPC Feature HW20 7 0 1 835 LDPC Feature...

Page 310: ...Feature FACTOR x16 4 7 617 LDPC Feature HW19 LDPC Feature HW20 4 7 616 LDPC Feature HW19 DSSS Feature LDPC Feature HP LDPC OFF 2 3 6 3 13 078 LDPC Feature HW19 LDPC Feature HW20 6 3 13 078 LDPC Featu...

Page 311: ...15 N x 64 64 1536 2048 IBS Feature HW9 for IESS IBS Feature Framing Only IBS Feature Framing Only N x 64 64 1536 2048 IBS Feature IBS Feature EF AUPC Less than 20 000 AUPC Feature AUPC Feature AUPC Fe...

Page 312: ...8PSK Turbo 1 2 256 14 8114 EBEM Feature HW28 256 44 433 EBEM Feature HW28 Standard 2 3 256 19 6914 EBEM Feature HW28 256 52 000 EBEM Feature HW28 Standard 3 4 256 22 1194 EBEM Feature HW28 256 52 000...

Page 313: ...TPC Feature HW27 Standard 7 8 8 4 14 737 TPC Feature HW27 TPC Feature HW27 TPC Feature HW27 8 4 20 000 TPC Feature HW27 Standard 8PSK TPC 3 4 10 8 18 947 8PSK TPC Feature HW27 8PSK TPC Feature HW27 8...

Page 314: ...ture HW27 6 4 20 000 LDPC Feature HW27 LDPC Feature 3 4 7 2 12 632 LDPC Feature HW27 LDPC Feature HW27 LDPC Feature HW27 7 2 20 000 LDPC Feature HW27 LDPC Feature ULL LDPC 1 2 4 7 8 308 LDPC Feature H...

Page 315: ......

Page 316: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...

Reviews: