CRS-150 1:1 Redundancy Switch
Revision 2
Connector Pinouts
MN/CRS150.IOM
3–4
3.2.2 Front Panel Terrestrial Data Connectors
3.2.2.1 Overhead Data Connector, DB-25M
The 25-pin ‘D’ Type male (DB-25M) Overhead data connector is used for
passing components of Intelsat specified overhead frame structures. These
include 64 kbps EIA-422 and 1/16 IBS overhead ESC at EIA-232. The
IDR backward alarm inputs are found on this connector.
Overhead Data Connector (DB-25M)
Pin #
Signal Function
Signal Name
Direction
14
IDR 64 kbps ESC TX Data +
TX-422DAT-B
In
2
IDR 64 kbps ESC TX Data -
TX-422DAT-A
In
12
IDR 64 kHz ESC TX Clock +
TX-422CLK-B
Out
15
IDR 64 kHz ESC TX Clock -
TX-422CLK-A
Out
11
IDR 1 kHz TX Octet Clock +
TX-OCT-B
Out
24
IDR 1 kHz TX Octet Clock -
TX-OCT-A
Out
16
IDR 64 kbps ESC RX Data +
RX-422DAT-B
Out
3
IDR 64 kbps ESC RX Data -
RX-422DAT-A
Out
9
IDR 64 kHz ESC RX Clock +
RX-422CLK-B
Out
17
IDR 64 kHz ESC RX Clock -
RX-422CLK-A
Out
19
IDR 1 kHz RX Octet Clock +
RX-OCT-B
Out
4
IDR 1 kHz RX Octet Clock -
RX-OCT-A
Out
20
Balanced Ext. Ref. Clock +
EXT-CLK-B
In
23
Balanced Ext. Ref. Clock -
EXT-CLK-A
In
13
IBS ESC RS232 TX Data
TX-232-DATA
In
22
IBS ESC RS232 TX Clock
TX-232-CLK
Out
8
IBS ESC RS232 RX Data
RX-232-DATA
Out
10
IBS ESC RS232 RX Clock
RX-232-CLK
Out
5
IBS TX High-Rate ESC Data
TX-ASYNC
In
6
IBS RX High-Rate ESC Data
RX-ASYNC
Out
1
IDR Back Alarm 1 H/W input
BW-IN1
In
18
IDR Back Alarm 2 H/W input
BW-IN2
In
21
IDR Back Alarm 3 H/W input
BW-IN3
In
25
IDR Back Alarm 4 H/W input
BW-IN4
In
7 Signal
Ground Ground
--
Summary of Contents for CRS-150
Page 14: ...CRS 150 1 1 Redundancy Switch Revision 2 Preface MN CRS150 IOM xiv Notes...
Page 22: ...CRS 150 1 1 Redundancy Switch Revision 2 Introduction MN CRS150 IOM 1 8 Notes...
Page 42: ...CRS 150 1 1 Redundancy Switch Revision 2 Connector Pinouts MN CRS150 IOM 3 18 Notes...
Page 74: ...CRS 150 1 1 Redundancy Switch Revision 2 Cable Drawings MN CRS150 IOM A 12 Notes...
Page 76: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...