etc). Its optimal location is 1.5 m above floor level. It can be placed on its own
stand or can be mounted on a wall.
IMPORTANT WARNING!
If the radiator valves in your flat are equipped
with a thermostatic head, adjust it to maximum temperature or replace the
thermostatic head of the radiator valve with a manual control knob in the
room where the room thermostat is to be located, otherwise the thermo-
static head may disturb the temperature control of the flat.
2. PUTTING THE THERMOSTAT INTO OPERATION
The device must be installed and connected by a qualified pro
-
fessional.
Warning!
Modifying the thermostat can cause electric shock or product
failure.
To put the thermostat into operation, detach the rear panel of the thermostat
from the front panel by pressing the lock on the upper side of the housing of
the thermostat, as shown in the figure.
Warning!
Alkaline batteries may only be used
for this appliance. Car-
bon-zinc batteries known as durable or long life batteries and chargeable
accumulators are not suitable for the operation of this appliance. Icon
appearing on the display to indicate low battery voltage warns reliably that
the batteries should be replaced only when
alkaline batteries
are used.
After the batteries have been inserted, the display flashes the measured
room temperature. (If this information fails to appear on the display, press
the „
RESET
” button located on the main panel of the thermostat.
3. BASIC SETTINGS
After removing the rear panel of the device, the following factory default
settings can be modified by relocating the jumpers (black plugs) and/or
changing the position of the orange-colored potentiometer located on the
main panel.
3.1 Selecting the Displayed Temperature
The temperature(s) to be shown on the display can be selected and set
by the left jumper.
With factory default settings the jumper is located on the central and
uppermost pins, in which case the display shows the currently measured
- 5 -