How to adjust distance and dispensing volume

 

Mount the KS15-2020 onto the wall (please see page 6). Then power on 

the unit; the Led indicator will flash 5 times. If there is no object in the 

sensor range for 30 seconds, the settings mode will be exited, and the 

dispenser will go into the default factory setting. 

1. Adjustment of sensor distance:

You can change the sensor distance if you require shorter or longer 

distances: 

a.

 

Press and hold the reset/settings button for 15 seconds; the Led 

indicator will start flashing first at a high frequency; once it drops to a

lower frequency, you can release the reset/settings button, now the 

dispenser is in settings mode, which lasts for 10 seconds.

b.

 

When in settings mode press and hold the reset/settings button 

again for 5 seconds, the Led indicator will light up continuously then 

flash fast for 5 seconds.

c.

 

Within these 5 seconds, put your hand under the dispenser at the

desired distance to set. The Led indicator will confirm with 4 slow

flashes.

d.

 

The sensor distance is now set to the required level.

Note: (The sensor distance should be 5-15cm)

2. Adjustment of dispensing volume

You can change the dispensing volume if you require more or 

less liquid. 

a.

 

Put the dispenser in settings mode, please note 1a above.

b.

 

When in settings mode, press the reset/settings button twice, the

Led indicator will start flashing.

c.

 

While the Led indicator is flashing, put your hand within sensor

range; the dispenser will start dispensing liquid in bursts while you 

keep your hand within sensor range, with a maximum of 7 bursts

(there are 7 different liquid levels for this dispenser).

d.

 

The moment it has dispensed the perfect amount of liquid, just move 

your hand away

e.

 

The dispensing volume is now set to the desired level.

Note: Please make sure that all adjustments of sensor distance or 

dispensing volume are completed within 30 seconds, otherwise the 

unit will exit settings mode and you will need to enter settings mode 

again to complete adjustments. 

Caution before installation

 

To make sure that the KS15-2020 functions well 

during its lifetime, please assure the below: 

1.

 

Please read this user manual and installation instruction before

assembling.

2.

 

Use 6 good quality AA batteries (alkaline). Do not use new and old 

batteries together, nor use other batteries.

3.

 

Please check the wall for evenness. Clean the wall before mounting the 

unit.

4.

 

Make sure the distance from the bottom of the dispenser to the closest

object or table beneath is greater than 25cm.

5.

 

Please provide this manual to the user after installation is complete.

6.

 

Don't put any barriers in the sensor range.

7.

 

To avoid sensor ghosting, don't put glossy (stainless steel) objects or

photoelectric sensors underneath the sensor window of the dispenser

(see installation instructions on page 5)

8.

 

Please position the dispenser out of the sun's reach as much as possible.

       WARNING: 

1. The dispenser could arrive in dormant mode and will initially not

respond. In this case, please hold the reset/settings button for

more than 2 seconds, the Led indicator will show for 3 seconds, 

putting the unit into normal operation mode.

2. Before first use, please run the commissioning cycle for 10 seconds:

press the reset/settings button 8 times. By pressing the

reset/settings button 1 time, the commissioning cycle can be

stopped. The commissioning cycle will stop automatically after 5

minutes.

3. If a longer period of non-usage (>72hrs) is expected, it is advised to

put the dispenser into dormant mode: press the reset/settings

button 5 times. In dormant  mode,  the  dispenser runs one time

per 72 hours if not used to avoid clogging.

4. To avoid accidental operation during cleaning or maintenance, set

the machine into dormant mode.

Summary of Contents for KS15-2020

Page 1: ... gel dispenser Please read this user manual carefully before installation and retain for future reference 2020 Component Hardware Group Component Hardware reserves the right to make any and all changes and to discontinue any of its products without notice Not responsible for typographical errors ...

Page 2: ...justable distance Sensor distance can be adjusted according to requirement Dispensed liquid volume is adjustable Designed with SCM Software Configuration Management Specification Model KS15 2020 Power supply 9V DC 6x 1 5V DC AA battery Liquid viscosity range cp 1 3500 1800 recommended Liquid capacity ml 650 Liquid alcohol content Tested to 75 Supply volume per drop ml 0 8 6 5 adjustable Flowing ti...

Page 3: ...tion instructions on page 5 8 Pleaseposition the dispenser out of the sun s reach as much as possible WARNING 1 The dispenser could arrive in dormant mode and will initially not respond In this case please hold the reset settings button for more than 2 seconds the Led indicator will show for 3 seconds putting the unit into normal operation mode 2 Before first use please run the commissioning cycle...

Page 4: ...t name KS15 2020 Key Top cover Battery Box Seal Battery Box Cover Gel Container Cap Protector Led Indicator Bottom View Gel Dispensing nozzle Sensor lens Reset Settings button Gel Container Wall Bracket 3 ...

Page 5: ...Wall bracket dimensions 84 5mm 3 33 205mm 8 07in 80mm 3 14in 58mm 2 28in 28 5mm 1 12in 4 ...

Page 6: ...Installation drawing Suggested positioning If to be installed above glossy stainless steel surfaces the distance from sensor window to surface must be over 35cm 5 ...

Page 7: ...e plastic plugs into these holes 2 Position the wall bracket and fix it to the wall with the screws supplied 3 Position the dispenser onto the wallbracket 4 Pushthe dispenser downwards make sureitfits intothe hook tightly 5 Secure the dispenser on the wall bracket with the set screw 6 Close the dispenser with the top cover and lock it with the key 6 ...

Page 8: ...Please make sure you install the batteries in the right direction the and side are indicated in the battery holder 6 Re position the battery box take especial care not to pinch the cable put the battery box cover back in place and tighten thescrews 7 Follow the instructions for setting the sensor range and volume of liquid if required f Unplug the cable and remove the battery box cover Remove the ...

Page 9: ...ith the key provided 5 Put your hand under the sensor window when the sensor detects the Led indicator will flash and liquid dispensesautomatically 6 Hold the reset settings button for more than 2 seconds at first use and activate the sensor until the liquid isdispensed Note Please remove the masking from the sensor lens before first use Please add liquid tothe dispenser as above Please put your h...

Page 10: ...nder the dispenser at the desired distance to set The Led indicator will confirm with 4 slow flashes d The sensor distance is now set to the required level Note The sensor distance should be 5 15cm 2 Adjustment of dispensingvolume You can change the dispensing volume if you require more or less liquid a Put the dispenser in settings mode please note 1a above b When in settings mode press the reset...

Page 11: ... Led indicator does not work Dispenser is in dormant state Switch off dormant state p 2 Sensor distance is too short Adjust to longer sensor distance The batteries do not function Check batteries and change if required Sensor window is not clean Clean sensor window Sensor failure Replace sensor Led indicator works but liquid is not dispensed Sensor is switching continuously Remove any barriers in ...

Page 12: ......

Reviews: