How to adjust distance and dispensing volume
Mount the KS15-2020 onto the wall (please see page 6). Then power on
the unit; the Led indicator will flash 5 times. If there is no object in the
sensor range for 30 seconds, the settings mode will be exited, and the
dispenser will go into the default factory setting.
1. Adjustment of sensor distance:
You can change the sensor distance if you require shorter or longer
distances:
a.
Press and hold the reset/settings button for 15 seconds; the Led
indicator will start flashing first at a high frequency; once it drops to a
lower frequency, you can release the reset/settings button, now the
dispenser is in settings mode, which lasts for 10 seconds.
b.
When in settings mode press and hold the reset/settings button
again for 5 seconds, the Led indicator will light up continuously then
flash fast for 5 seconds.
c.
Within these 5 seconds, put your hand under the dispenser at the
desired distance to set. The Led indicator will confirm with 4 slow
flashes.
d.
The sensor distance is now set to the required level.
Note: (The sensor distance should be 5-15cm)
2. Adjustment of dispensing volume
You can change the dispensing volume if you require more or
less liquid.
a.
Put the dispenser in settings mode, please note 1a above.
b.
When in settings mode, press the reset/settings button twice, the
Led indicator will start flashing.
c.
While the Led indicator is flashing, put your hand within sensor
range; the dispenser will start dispensing liquid in bursts while you
keep your hand within sensor range, with a maximum of 7 bursts
(there are 7 different liquid levels for this dispenser).
d.
The moment it has dispensed the perfect amount of liquid, just move
your hand away
e.
The dispensing volume is now set to the desired level.
Note: Please make sure that all adjustments of sensor distance or
dispensing volume are completed within 30 seconds, otherwise the
unit will exit settings mode and you will need to enter settings mode
again to complete adjustments.
Caution before installation
To make sure that the KS15-2020 functions well
during its lifetime, please assure the below:
1.
Please read this user manual and installation instruction before
assembling.
2.
Use 6 good quality AA batteries (alkaline). Do not use new and old
batteries together, nor use other batteries.
3.
Please check the wall for evenness. Clean the wall before mounting the
unit.
4.
Make sure the distance from the bottom of the dispenser to the closest
object or table beneath is greater than 25cm.
5.
Please provide this manual to the user after installation is complete.
6.
Don't put any barriers in the sensor range.
7.
To avoid sensor ghosting, don't put glossy (stainless steel) objects or
photoelectric sensors underneath the sensor window of the dispenser
(see installation instructions on page 5)
8.
Please position the dispenser out of the sun's reach as much as possible.
WARNING:
1. The dispenser could arrive in dormant mode and will initially not
respond. In this case, please hold the reset/settings button for
more than 2 seconds, the Led indicator will show for 3 seconds,
putting the unit into normal operation mode.
2. Before first use, please run the commissioning cycle for 10 seconds:
press the reset/settings button 8 times. By pressing the
reset/settings button 1 time, the commissioning cycle can be
stopped. The commissioning cycle will stop automatically after 5
minutes.
3. If a longer period of non-usage (>72hrs) is expected, it is advised to
put the dispenser into dormant mode: press the reset/settings
button 5 times. In dormant mode, the dispenser runs one time
per 72 hours if not used to avoid clogging.
4. To avoid accidental operation during cleaning or maintenance, set
the machine into dormant mode.
9
2