Quick Start
For a quick look at the abilities of the HT-20KVPac, we are providing this quick start
page, designed to get you up and running quickly. We recommend that you read the entire
manual before using the HT-20KVPac to conduct actual testing.
Initial Setup
1.
Remove the HT-20KPac from its shipping carton and set it up on a bench.
2.
Plug it in to a correctly rated source of supply, using the supplied cordset.
3.
Turn on the tester using the AC Power Switch.
4.
Change the Test Timer Switch to DEFEAT position.
5.
Turn the Voltage Adjust knob fully counterclockwise to set output voltage to minimum.
6.
Push the RESET Button.
7.
Push and hold the TEST Button. (The output voltage is present only while the TEST Button
is pressed when the Test Timer Switch is set to the DEFEAT position)
.
8.
Set the desired voltage level using the Voltage Adjust knob.
9.
Release the TEST button; output voltage will drop to zero.
10.
Plug the red High Voltage lead into the output.
11.
Plug the black lead into the Return jack.
12.
Connect the Test Leads across the part to be tested.
13.
Push and hold the TEST Button and observe the front panel meters and lights for test results.
14.
Release the TEST button to finish the Test.