background image

 

Front Panel Features 

 

Before using your Tester, take a few minutes to become familiar with the use of  its controls, indicators 
and connectors.  The front panel features of the GFM-200A are shown in Figure 2-1 and described in 
Table 2-1.  
 
 

 

 

Figure 2-1.  Controls, Indicators, Connectors - Model GFM-200A Front Panel 

 
 
 

Front Panel Description 

 

ITEM NO.

 

                    NAME

 

                                      

FUNCTION

 

Variac Knob 

The  Variac  knob  increase  or  decrease  the  current 
outpu  of  the  GFM-200.  Before  operating  the  tester 
turn down the knob to the minimum.. 

 

ON/OFF Switch 

The  ON/OFF  Switch  allows  to  operate  the  unit, 
always turn OFF the unit when not operated. 

Current Meter 

The Current Meter show the current that is flowing 
thru the output of the GFM-200A.  

Voltage Meter 

The  Voltage  Meter  show  the  voltage  that  is  on  the 
output of the GFM-200A. 

 

Table 2-1.  Controls, Indicators, Connectors - Model GFM-200A Front Panel 

 

 
 
 

 
 
 

 

 

Summary of Contents for GFM-200A

Page 1: ...GFM 200A Instruction Manual...

Page 2: ...nel and represents the latest in high current production line testing To fully appreciate all the features of your new meter we suggest that you take a few moments to review this manual Compliance Wes...

Page 3: ...Fuse Replacement 3 Front Panel Features 4 Front Panel Description 4 Rear Panel Features 5 Rear Panel Description 5 Initial Checkout Procedure 6 Operating Techniques 6 Technical Assistance 7 Maintenan...

Page 4: ...1...

Page 5: ...s warranted for a period of one year upon shipment of the instrument to the original purchaser Specifications Specifications for the GFM 200A are listed in Table 1 1 GFM 200A Specifications ELECTRICAL...

Page 6: ...ailable be sure that adequate protection is provided to prevent damage during shipment We recommend that the instrument be surrounded by at least one inch of shock absorbing material on all sides of t...

Page 7: ...TEM NO NAME FUNCTION 1 Variac Knob The Variac knob increase or decrease the current outpu of the GFM 200 Before operating the tester turn down the knob to the minimum 2 ON OFF Switch The ON OFF Switch...

Page 8: ...ied cordset to connect the GFM 200A tester to an appropriate source of supply 2 Fuse Fuse holder provides access for Fuse replacement 3 Output Tester Output is located in the back use the cable attach...

Page 9: ...h 9 Short circuit the output leads and connect a current clamp meter at one of the leads 10 Turn the power switch to the I or ON position 11 Increase the current by turning the variac knob clockwise a...

Page 10: ...rom Compliance West USA is available Phone 800 748 6224 Hours 8 30 AM 4 30 PM Pacific Time Also available on our web site at www compwest com Contact Compliance West USA 650 Gateway Center Way Suite D...

Page 11: ...t no charge Mail the instrument post paid to the manufacturer Dated proof of purchase is required for all in warranty repairs The manufacturer is also available for calibration and or repair of instru...

Page 12: ...has been repaired The calibration procedure should be performed at an ambient temperature of 23 C 5 C 73 4 F 9 F The procedure consists in the verification and calibration of the meter reading The Cal...

Reviews: